Simplex 4098-9838 TrueAlarm Maximum Security Sensor Guard - Installation Instruction

File Preview
File Preview
Click below to download for free

Text Preview

Cautions and Warnings TrueAlarm cid 228 Security Sensor Guard Instructions NOT INSTALL ANY SIMPLEX PRODUCT THAT APPEARS Upon unpacking your Simplex product inspect the contents of the for shipping damage If damage is apparent immediately file a claim the carrier and notify Simplex HAZARD Disconnect electrical power when making any adjustments or repairs Servicing should be performed by qualified Representatives HAZARD Static electricity can damage components Therefore as follows Ground yourself before opening or installing components use the 553 484 Control Kit Keep uninstalled component wrapped in anti static material at all times publication shows how to install the 4098 9838 TrueAlarm Maximum Sensor Guard The sensor guard is a device that is mounted on a ceiling provide protection for a 4098 9714 Smoke Sensor DO NOT wall mount the sensor guard Seal the electrical box using 3M Weatherban 606 or equivalent Using the information shown in Figure 2 drill holes for appropriate per local building codes After the sensor and base are installed refer to notes below secure the guard mounting frame to the ceiling using 1 4 inch minimum hex head bolts with lead expansion shields or toggle bolts not Avoid plastic shields sensor base is a 4098 9789 4098 9791 4098 9792 or only Use 4098 9714 sensor only see the Warning in Figure 1 Refer to Simplex Publication 4098 Smoke Heat Sensor Bases Instructions 574 707 when installing sensor bases Place the sensor guard cover in the mounting frame Secure the cover to the frame using four 10 24 x 1 2 inch long button head with center pin screws Use 4098 9823 5 32 inch Tamperproof Hex 553 692 not supplied to install the screws DO NOT paint the sensor guard on next page Steps 1 through 5 and refer to Figures 1 and 2 to install the sensor guard 1998 Simplex Time Recorder Co Gardner MA 01441 0001 USA specifications and other information shown were current as of publication and are subject to change without notice A Continued Box Mounted Supplied Sensor Warning Below with 4098 9791 or 4098 9793 Base 10 24 x 1 2 Inch Hex with Center Screws Supplied Guard Frame 1 4 inch Diameter Bolts Supplied Guard Cover Use only a 4098 9714 sensor Refer to 2120 Job Report or Custom Control Equation in the 4010 4020 or 4100 Programmer Report verify the sensitivity range is between 0.5 to 1.5 foot obscuration 1 Installing the Sensor Guard with a 4098 9789 9791 9792 or 9793 Sensor Base and Testing recommends routine cleaning of the smoke sensor and guard so that and other matter does not accumulate Refer to 4098 Detectors Sensors Bases Application Manual 574 709 for details The strength of final installation requires heavy anchoring The flush mounted electrical box be installed even to the surface or be recessed maximum template is shown to scale NOT photocopy use template follow steps 1 3 this template flat on the ceiling which the sensor guard is to be installed holes for appropriate anchoring per building codes the sensor guard mounting frame NOT wall mount the sensor guard 2 Sensor Guard Template A Time Recorder Co Simplex Plaza Gardner Massachusetts 01441 0001 U S A

Related Files