Simplex 4099-9701, 4099-9702, 4099-9703, 4099-9704, CN4099-9032 IDNet Communicating Devices, Internal Addressable Callpoint; (-2, formatted for 8 5 x 11 inch) (B) (C)

File Preview
File Preview
Click below to download for free

Text Preview

I O Devices IDNet Communicating Devices Addressable Manual Callpoint addressable manual fire alarm with Power and data supplied via IDNet addressable using a single wire pair Enhanced aesthetics Designed for fast and easy installation Designed for EMI compatibility Surface or flush mounting options Test key allows the callpoint to be tested without the glass Requires a special key to open the callpoint with Simplex Model series and 4100U addressable manual callpoints with compact module are easily installed to satisfy applications An integral individual module IAM monitors status and changes to the connected control panel via communications and Means Type Connections and Operating Range Range Protection to 95 RH non condensing RAL3001 H x 3 1 2 W x 1 1 16 D mm x 89 mm x 28 mm 8 position terminals This product is not presently agency listed Contact your local Simplex product supplier for to 131 10 C to 55 C 1 address per callpoint latest status Addressable Manual Callpoint of the Simplex callpoint requires the glass to be broken Completing the action operates a whose condition is signaled back to the panel reset requires the use of a special key with the callpoint to remove the front cover allows the glass element to be replaced testing is performed by inserting the key into the bottom of the housing and pulling down releases the bottom of the housing and break glass To reset the callpoint the bottom of the housing pushed upwards until it locks in position See below Testing 3 2009 Reference to NFPA 72 the National Fire Alarm Code and all local codes for complete requirements for callpoints The following summarizes the basic Callpoints shall be located in the normal path of exit distributed in the protected area such that they unobstructed and readily accessible Mounting shall be with the operable part not less than ft 1.1 m and not more than 4 1 2 ft 1.37 m floor level At least one callpoint shall be provided on each floor callpoints shall be provided to obtain a distance not more than 200 ft 61m to the callpoint from any part of the building When manual callpoint coverage appears limited in way additional callpoints should be installed Product Selection Manual Callpoints with Internal IAM callpoint with LED callpoint no LED callpoint with LED callpoint with LED callpoint with LED mount backbox for Simplex internal callpoints 32 mm deep 1 1 4 replacement glass package of 10 Mounting Information The callpoint fits directly to a UK switch socket A minimum box depth of 25 mm is recommended PC ABS Backbox for surface mounting 3 2009 Setting the Callpoint Address Replacing the Break Glass Element 3 2009 is a registered trademark of Tyco International Services GmbH and is used under license Simplex the Simplex logo and IDNet are trademarks of Tyco International Ltd its affiliates and are used under license NFPA 72 and National Fire Alarm Code are trademarks of the National Fire Protection Association NFPA 2009 Tyco Safety Products Westminster All rights reserved All specifications and other information shown were current as of document revision date and are subject to change without notice Safety Products Westminster Westminster MA 01441 0001 USA 3 2009

Related Files