System Sensor 8251F-CLIP EngSpec

File Preview
File Preview
Click below to download for free

File Data

Name system-sensor-8251f-clip-engspec-5480912763.pdf
Type PDF
Size 660.07 KB
Downloads

Text Preview

8251F CLIP Aspirating Smoke Detector and Engineering Specifications Aspirating Smoke Detector ASD shall offer Very Early Warning Smoke Detection Early Smoke Detection and Standard Smoke Detection settings The sensitivity range shall be 0.00046 ft 4.0 ft Operating temperatures shall be from 32 0 to 100 38 air temperatures shall range from to 140 60 Operating humidity range from 10 95 non condensing The ASD shall have dual source blue LED and infra laser optical smoke detection for a wide range of fire detection with enhanced immunity to particulates The ASD shall operate in air flows from 0 4000 ft min 0 1,219 m min software shall provide pipe design FAAST system configuration and FAAST system in a single software program ASD shall be tested approved and or listed by Underwriters Laboratories UL Factory FM and California State Fire Marshal CSFM Parameters ASD shall allow 5 programmable alarm levels with time delays including Alert Action 1 2 Fire 1 and Fire 2 The ASD shall allow for an Acclimate or Day Night Weekend setting accommodate environmental changes The Acclimate mode shall automatically adjusts alarm within user specified parameters to reduce nuisance alarms It shall continually adapt to environmental conditions when activated Day Night Weekend settings shall allow the to create different thresholds and delays during the day night or weekend ASD shall provide 8 form C programmable latching or non latching relays It shall include a replaceable filter and an internal particle separator to reduce the amount of non combustible reaching the detection chamber It shall be tested and approved for coverage up to sq ft It shall use ultrasonic sensors to confirm proper air flow through the pipe network It store up to 18,000 events Events shall include smoke levels alarm conditions operator and faults The dates and time of each event shall be recorded ASD shall provide Urgent Minor and Isolate fault types to indicate the priority of faults in the system Fault indication shall be provided for the following flow If a device has decreased air flow a Minor fault shall be generated at 20 in air flow An Urgent fault shall be generated at 50 decrease in air flow Configuration Device configuration failure A minor fault shall be generated if a update did not transfer An Urgent fault shall be generated if no exists in the system or the configuration is corrupt and the device cannot Sensor If the particulate sensor is not operating properly and needs immediate an Urgent fault shall be generated External Monitor If the external monitor detects an open a Minor fault shall be Time If the internal time base needs to be updated a Minor fault shall be generated Communication If the device fails to communicate to one of its peripherals and cannot properly an Urgent fault shall be generated Aspiration If the aspirator is not working and requires immediate attention an Urgent shall be generated Filter As the filter approaches a pre set threshold an initial warning shall be given to the filter and a Minor fault shall be generated If the filter is not changed within 72 an Urgent fault shall be generated If the device is put into the Isolate mode an Isolation fault shall be generated High Flow If a device has increased air flow a Minor fault shall be generated at 20 in air flow An Urgent fault shall be generated at 50 increase in air flow Interface system shall provide a user interface with Air Flow Fault Display The air flow fault display shall consist of 10 bicolor LEDs and in one of two modes air flow or fault indication Green segments shall indicate close the current air flow is to the high or low air flow threshold During normal two adjacent indicators shall be green and correspond to the current airflow the detector When airflow is at a balanced level the two green segments shall centered on the graph As airflow rises and falls the green segments shall move right left accordingly If a fault is activated on the device the corresponding LEDs shall in amber and an additional LED shall be triggered to signal a fault has generated All 10 faults shall be indicated on the User Interface particulate levels The particulate level display shall consist of ten amber LEDs that to the current level of the particulate detected The LEDs shall illuminate in from Level 1 to Level 10 starting from the bottom of the display and moving up as particulate level increases Each LED shall represent a 10 increase in the level necessary to reach the Alert Alarm level alarm levels All 5 Alarm levels shall be indicated on the User Interface The Alarm Display shall consist of 5 red LEDs that correspond to the current alarm level LEDs shall be located directly above the Particulate Level LEDs They shall sequentially upward as the severity of the alarm increases On Off indication Voltage indication user interface shall offer interactive buttons The buttons shall have a security passcode to prevent unauthorized access if chosen The buttons shall allow the following features to activated at the device Test Reset Generation the buttons shall provide the local device address and the IP of the device through a coded sequence Password input if required to activate buttons software shall include a single software program PipeIQ which provides pipe network ASD configuration and system monitoring The software shall provide the ability to monitor the system The software shall have the ability to provide the following Test reset and isolate functions from remote locations Bill of Materials for the pipe network Pipe layout of the pipe network Generate transportation time from the sampling holes to the detector and sampling hole event monitoring Historic event retrieval Custom message function to input messages about a device or site Configuration settings Network settings Trend graph reflecting obscuration over time ASD shall include an onboard Web server interface to enable remote monitoring and device Connection to the device shall be through an RJ45 jack A password shall be to access the Web server The software shall include the ability to enter up to 6 e mail to send automatic updates for alarms and or faults Each e mail address shall have ability to select the type of updates which will be sent The network shall support up to 255 Alarm Control Panel Connectivity ASD shall communicate directly with the Fire Alarm Control Panel FACP using the protocol native to the FACP The ASD shall communicate with the FACP via connection to the Signaling Line Circuit SLC without additional hardware facilitating the ASD shall initiate five 5 distinct fire events at the FACP Alert Action 1 Action 2 Fire 1 2 The ASD shall report general and specific fault events at the FACP low high airflow sensor time communication aspirator filter isolate low voltage following operations shall be able to be performed on the device via the FACP reset airflow disable isolate test reset following device configurations shall be able to be performed on the device via the FACP air flow fault boundary set air flow fault timer user interface button lock and unlock reset configuration lock configuration ASD shall communicate the ModBus protocol using the onboard Ethernet connection The shall be able to receive remote configuration as well as be monitored remotely when the function is employed ModBus communications shall be enabled without inhibiting the functions of the PipeIQ or the device integral web server Each of these communication capabilities shall be simultaneously System ASD shall consist of a pipe network to transport air to the detection system supported by from a computer based design modeling tool The single pipe length shall extend up 262 ft 80 m The outside pipe diameter shall fit either 1.050 inches or 25mm Inter

Related Files