System Sensor CZ-6 EngSpec

File Preview
File Preview
Click below to download for free

File Data

Name system-sensor-cz-6-engspec-8436725190.pdf
Type PDF
Size 621.47 KB
Downloads

Text Preview

Product Six Zone Interface Intelligent Module and Engineering Specifications six zone interface intelligent module shall be a System Sensor model number CZ 6 module shall provide an interface between the intelligent alarm system and a two wire detection zone All two wire detectors being monitored must be two wire UL listed with the modules The module shall transmit the status of a zone of two wire to the fire alarm control panel Status conditions are reported as normal open or alarm common signaling line circuit SLC input shall be used for all modules and the initiating device will share a common external supply Otherwise each module shall operate from the others The interface module shall supervise the zone of detectors and connection of the external power supply module shall supervise the zone of detectors and the connection of the external power The module shall provide terminal connections for a resettable external supply voltage to power to the initiating device circuit IDC or zone of two wire smoke detectors Module have ability to signal faults related to open circuit or no power supply connected module shall have its own address A pair of rotary code switches shall be used to set the of the first module from 01 to 94 The remaining modules shall be automatically assigned the next five sequential addresses Because of the possibility of installation error systems that binary jumpers or dipswitches to set the module address are not acceptable Provisions are for disabling a maximum of two unused modules to release the addresses to be used The modules shall also store an internal identifying code that the control panel shall to identify the type of module Systems that require a special programmer to set the module including temporary connection at the panel are labor intensive and not acceptable module responds to regular polls from the system and reports its type and status module address shall have an associated LED that is controlled by the panel to indicate status Coded signals transmitted from the panel can cause the LED to blink latch on latch off Refer to the control panel technical documentation for module LED status operation IDC zone shall be wired for Class A Style D or Class B Style B operation The module use plug in terminal blocks for easy wiring Wiring terminals shall be easily accessible for while installed UL 864 Control Units and Accessories for Fire Alarm Systems Agency Standards ULC S527 Control Units for Fire Alarm Systems NFPA 72 National Fire Alarm Code 2010

Related Files