System Sensor L-Series Horns, Strobes, and Horn Strobes - Wall (AVDS865)

File Preview
File Preview
Click below to download for free

Text Preview

Indoor Selectable Horns and Strobes for Applications Sensor L Series audible visible notification are rich with features guaranteed to cut times and maximize profits with lower draw and modern aesthetics Updated Modern Aesthetics Small profile devices for Horns and Horn Strobes Plug in design with minimal intrusion into the back box Tamper resistant construction Automatic selection of 12 or 24 volt operation at 15 and 30 Field selectable candela settings on wall units 30 75 95 110 135 and 185 Horn rated at 88 dBA at 16 volts Rotary switch for horn tone and two volume selections Mounting plate for all standard and all compact wall units Mounting plate shorting spring checks wiring continuity before installation Electrically compatible with legacy SpectrAlert and SpectrAlert Advance devices Compatible with MDL3 sync module Strobes and Horn Strobes listed for wall mounting only Horns listed for wall or ceiling use Listings approved except ALERT models 3057072 System Sensor L Series offers the most versatile and line of horns strobes and horn strobes in the industry lower current draws and modern aesthetics With white and red housings standard and compact devices and plain FIRE FUEGO printed devices System Sensor L Series can virtually any application requirement L Series line of wall mount horns strobes and horn strobes a variety of features that increase their application versatility simplifying installation All devices feature plug in designs minimal intrusion into the back box making installations fast foolproof while virtually eliminating costly and time consuming faults further simplify installation and protect devices from construction the L Series utilizes a universal mounting plate for all with an onboard shorting spring so installers can test wiring before the device is installed can also easily adapt devices to a suit a wide range application requirements using field selectable candela settings selection of 12 or 24 volt operation and a rotary switch horn tones with two volume selections 2 22 2018 Page 1 Specifications Specifications standard horns strobes and horn strobes shall mount to a standard 2 x 4 x 17 8 inch back box 4 4 1 back box 4 inch back box or double gang back box L Series compact products shall mount to a single gang 2 4 17 back box A universal plate shall be used for mounting ceiling and wall products for all standard models and a separate universal mounting plate shall be for mounting wall compact models The notification appliance circuit wiring shall terminate at the universal mounting plate Also L Series when used with the Sync Module accessory shall be powered from a non coded notification appliance circuit output shall operate on a nominal 12 or 24 volts When used with the Sync Module 12 volt rated notification appliance circuit outputs operate between 8.5 and 17.5 volts 24 volt rated notification appliance circuit outputs shall operate between 16.5 and 33 volts Indoor products shall operate between 32 and 120 degrees Fahrenheit from a regulated DC or full wave rectified unfiltered power supply and horn strobes shall have field selectable candela settings including 15 30 75 95 110 135 and 185 strobe shall be a System Sensor L Series Model listed to UL 1971 and shall be approved for fire protective service The strobe be wired as a primary signaling notification appliance and comply with the Americans with Disabilities Act requirements for visible appliances flashing at 1 Hz over the strobe entire operating voltage range The strobe light shall consist of a xenon flash tube and lens reflector system Strobe Combination horn strobe shall be a System Sensor L Series Model listed to UL 1971 and UL 464 and shall be approved for fire protective The horn strobe shall be wired as a primary signaling notification appliance and comply with the Americans with Disabilities Act for visible signaling appliances flashing at 1 Hz over the strobe entire operating voltage range The strobe light shall consist a xenon flash tube and associated lens reflector system The horn shall have two audibility options and an option to switch between a three pattern and a non temporal continuous pattern These options are set by a multiple position switch The horn on horn strobe shall operate on a coded or non coded power supply Module module shall be a System Sensor Sync model MDL3 listed to UL 464 and shall be approved for fire protective service The shall synchronize Strobes at 1 Hz and horns at temporal three Also while operating the strobes the module shall silence the horns horn strobe models over a single pair of wires The module shall mount to a 411 16 411 16 21 8 inch back box The module shall also two Style Y class B circuits or one Style Z class A circuit The module shall synchronize multiple zones Daisy chaining two or more modules together will synchronize all the zones they control The module shall not operate on a coded power supply Specifications Operating Temperature Range Flash Rate Voltage Voltage Range2 Voltage Range MDL3 Sync Module Terminal Wire Gauge Dimensions including lens Wall Mount Dimensions including lens Dimensions Horn Dimensions Full Wave Rectified FWR voltage is a non regulated time varying power source that is used on some power supply and panel outputs Strobe products will operate at 12 V nominal only for 15 cd and 30 cd to 120 0 to 49 to 93 non condensing flash per second 12 DC or regulated 24 DC FWR1 to 17.5 V 12 V nominal or 16 to 33 V 24 V nominal to 17.5 V 12 V nominal or 16.5 to 33 V 24 V nominal to 18 AWG L 4.7 W 1.91 D 143 mm L 119 mm W 49 mm D L x 3.46 W x 1.91 D 133 mm L x 88 mm W x 49 mm D L 4.7 W 1.25 D 143 mm L 119 mm W 32 mm D L x 3.45 W x 1.25 D 133 mm L x 88 mm W x 32 mm D 2 22 2018 Page 2 Current Draw Data Max Strobe Current Draw mA RMS Volts Volts Max Horn Current Draw mA RMS Pattern KHz Temporal KHz Temporal KHz Non Temporal High KHz Non Temporal Low KHz Coded Volts 16 Volts Max Current Draw mA RMS Wall Horn Strobe Candela Range 15 cd Input High Low High Low Temporal High Temporal Low Non Temporal High Non Temporal Low Input High Low High Low Temporal High Temporal Low Non Temporal High Non Temporal Low Volts Volts Volts Tones and Sound Output Data and Horn Strobe Output dBA KHz Temporal KHz Temporal KHz Non Temporal High KHz Non Temporal KHz Coded Sound Pattern Settings 9 and 10 are not available on 2 wire horn strobes Temporal coding must provided by the NAC If the NAC voltage is held con

Related Files