System Sensor L-Series Speakers and Speaker Strobes - Ceiling

File Preview
File Preview
Click below to download for free

Text Preview

Indoor Selectable Speaker and Dual Evacuation for Ceiling Sensor L Series selectable output speaker strobes dual voltage evacuation speakers can reduce ground and enable faster installation with lower current draw modern aesthetics Plug in design and protective cover reduce ground faults Universal mounting plate with an onboard shorting spring tests continuity before installation No extension ring required Field selectable candela settings on ceiling units 30 75 95 115 150 and 177 Automatic selection of 12 or 24 volt operation 15 and 30 candela Rotary switch simplifies field selection of speaker voltage 25 70.7 Vrms and power settings 1 and 2 watts Speakers offer high fidelity and high volume sound output 520 Hz capable with compatible FACP Electrical compatibility with existing SpectrAlert and SpectrAlert Advance products Tamper resistant construction Updated modern aesthetics Listings approved except ALERT models Sensor L Series of speakers and speaker strobes costly ground faults using a plug in design and universal plate that allow the installer to pre wire mounting plates the wires and confirm wiring continuity before plugging in the In addition a protective plastic cover prevents nicked by covering exposed speaker components devices also enable faster installations by providing instant to ensure that wiring is properly connected rotary switches select voltage and power settings and 7 field selectable candela for both wall and ceiling speaker strobes low total harmonic distortion of the SP speaker offers high fidelity output while still offering high volume sound output for use in ambient noise applications makes installation easy Attach a universal mounting plate to a 4 4 21 inch back box Connect the notification appliance circuit or speaker wiring to the on the mounting plate Attach the speaker or speaker strobe to the mounting plate by the product tabs into the mounting plate grooves Hinge device into position to lock the product pins into the mounting terminals The device will temporarily hold in place with a until it is secured with a captured mounting screw Compatible with System Sensor synchronization protocol applications do not require an extension ring Speaker and Speaker Strobe Specifications Specifications speaker and speaker strobes shall mount to a 4 4 21 back box A universal mounting plate shall be used for mounting and wall products The notification appliance circuit and amplifier wiring shall terminate at the universal mounting plate Also L Series strobes when used with the Sync Module accessory shall be powered from a non coded notification appliance circuit and shall operate on a nominal 12 or 24 volts When used with the Sync Module 12 volt rated notification appliance circuit shall operate between 8.5 and 17.5 volts 24 volt rated notification appliance circuit outputs shall operate between 16.5 and 33 volts L Series products shall operate between 32 and 120 from a regulated DC or full wave rectified unfiltered power supply Speaker shall have field selectable candela settings including 15 30 75 95 115 150 177 speaker shall be a System Sensor L Series model dual voltage transformer speaker capable of operating at 25.0 or 70.7 nominal It should be listed to UL 1480 and shall be approved for fire protective service The speaker shall have a frequency range of 400 to Hz and shall have an operating temperature between 32 and 120 The speaker shall have power taps and voltage that are selected rotary switches Strobe combination speaker strobe shall be a System Sensor L Series model listed to UL1480 and UL 1971 and be approved for fire protective systems The speaker shall be capable of operating at 25.0 or 70.7 nominal Vrms selected via rotary switch and shall have a range of 400 to 4,000 Hz The speaker shall have power taps that are selected by rotary switch The strobe shall comply with the 72 requirements for visible signaling appliances flashing at 1 Hz over the strobe entire operating voltage range The strobe light shall of a xenon flash tube and associated lens reflector system Module module shall be a System Sensor Sync model MDL3 listed to UL 464 and shall be approved for fire protective service The module synchronize SpectrAlert strobes at 1 Hz The module shall mount to a 411 411 21 back box The module shall also two Style Y class B circuits or one Style Z class A circuit The module shall synchronize multiple zones Daisy chaining two or more modules together will synchronize all the zones they control The module shall not operate on a coded power supply in 25 mm in 89 mm in 73 mm in 136 mm to 120 0 to 49 to 93 non condensing in 173 mm in 176 mm in 173 mm in 176 mm Specifications Temperature Range Ceiling Mount Speaker Surface Mount Back Box Speaker Strobe Surface Mount Back Box Specifications Voltage speakers Supervisory Voltage speakers Flash Rate Voltage strobes Voltage Range includes fire panels with built in sync Voltage with MDL3 Sync Module Range Full Wave Rectified FWR voltage is a non regulated time varying power source that is used on some power supply and panel outputs Strobe products will operate at 12 V nominal only for 15 and 30 cd 520Hz capable with compatible FACP Volts or 70.7 Volts nominal VDC flash per second 12 VDC or regulated 24 VDC FWR 1,2 to 17.5 V 12 V nominal or 16 to 33 V 24 V nominal to 17.5 V 12 V nominal or 16.5 to 33 V 24 V nominal to 4,000 Hz3 1 2 watts Current Draw Data Max Strobe Current Draw mA RMS to 17.5 Volts to 33 Volts Speaker Sound Output W W W W Reverberant dBA 10 ft Speaker Strobe Sound Output W W W W Reverberant dBA 10 ft Dimensions Anechoic dBA 10 ft Anechoic dBA 10 ft Speaker Speaker Strobe Mounting Speaker with Surface Mount Back Box Speaker Strobe with Surface Mount Back Box Ordering Information Mount only Strobe Speaker Strobe Speaker Strobe Speaker Strobe Clear Lens Ceiling Surface Mount Back Box Ceiling Trim Ring Ohio Avenue St Charles IL 60174 800 SENSOR2 Fax 630 377 6495 specifications subject to change without notice Visit systemsensor com current product information including the latest version of this data sheet System Sensor 03 17

Related Files