System Sensor PSP1 Manual

File Preview
File Preview
Click below to download for free

File Data

Name system-sensor-psp1-manual-7892140635.pdf
Type PDF
Size 696.24 KB
Downloads

Text Preview

INSTALLATION AND MAINTENANCE INSTRUCTIONS Plug in Special Purpose Switch S Patent Number 6,037,867 4.73 L x 2.94 W x 2.21 D 12 cm L x 7.5 cm W x 5.6 cm D With bracket 8.5 L 21.5 cm L 1.7 lbs 774kg Rating Cast aluminum rain tight outlet box Indoor Outdoor NEMA 3 Protection Cover tamper switch and tamper proof cover screws Voltage 6 12 24 volts AC DC Operating Current 250 mA Temperature F to 149 F C to 65 C 1 PSP1 Ohio Avenue St Charles Illinois 60174 FAX 630 377 6495 Read Carefully and Save instruction manual contains important information the installation and operation of this supervisory This manual should be left with the owner user of equipment Information unit is intended for supervision of non rising stem valves and other valves that cannot be monitored conventional supervisory switches Turning the valve will pull the plug out of the jack and close a set of open contacts A lockout will prevent reinsertion require removal of the cover Tamperproof screws are for the cover Removal of cover or cutting of cord ground faults will cause an open circuit The device be wired to the trouble circuit of a fire alarm con panel Choose a location near the valve safe from flooding mount the bracket to the wall Rotate the box on the bracket until the plug faces the The plug must also point downward Tighten the on the pivot Turn the valve to the full open position Insert the plug the jack Tightly loop the 8 ft waterproof cable the valve wheel and back into the box through cable clamp Close valve to check that plug pulls out then turn valve back to full open position Cut the to the minimum length required to make the con within the box conduit connectors Wire the device as per the circuit diagrams shown see 2 5 Trim the unused black wire flush with the casing and cap the red wire of the cover tamper For all exterior applications use 1 2 NPT listed liquid Using the adhesive pad and wire tie provided dress the If a longer cable is required use SJOW A 18 2 two con 18 gauge stranded rubber jacketed cable away from the lock out mechanism When installing the cover make sure the O rings are in on the cover screws beneath the cover 1 I56 0984 005R 2 Single device Class B stipulated by Factory Mutual and Underwriter this unit is not intended or designed for usage It is a special application device to be used unusual conditions where no other approved or listed of protection is available or practical such as non stem gate valves this unit does not meet NFPA codes and standards restoration of the signal when the valve is posi to normal special attention should be given by responsible parties to assure that the proper operation this device is maintained This device should only be to normal when the valve is in normal condition 3 Multiple devices Class B

Related Files