System Sensor SAA MDL3R and MDL3W Manual

File Preview
File Preview
Click below to download for free

File Data

Name system-sensor-saa-mdl3r-and-mdl3w-manual-4327508691.pdf
Type PDF
Size 1.24 MB
Downloads

Text Preview

INSTALLATION AND MAINTENANCE INSTRUCTIONS Series Sync Module use with the following series models ULC listed models CHRX CHWX CHSRX CHSWX HRX HWX MHR A MHW A P2RX P2WX P4RX P4WX PC4RX PC4WX PC24XX PC2RX SCRX SCWX SC24XX SRX SWX B200S A listed SP2C24XX SPSX SPSCX SEP SW SEP SPSW listed models HC12 24X SPSX V models only SPSCX V models only MHRZA MHWZA SEP SW A SEP SPSW A models for reverse compatibility reference CH24MCX H12 24X PA400X S1224MCX SP2R1224MCX SP2W1224MCX to System Sensor product installation manuals for model specifications Ohio Avenue St Charles Illinois 60174 Fax 630.377.6495 Voltage Range Load on Loop A Draw 12VDC FWR 8.0 to 17.5V or 24VDC FWR 16.0 to 33V V V Slave Input 3 Strobes are connected to sync mod MDL3 input voltage range at 12V 8.5 to at 24V 16.5 to 33VDC FWR Temperature to 120 0 to 49 UL1971 ULC S525 ULC S526 1 For maximum number of strobes and or maximum line impedance refer to the voltage drop calculator found at Systemsensor com and 2 Maximum impedance as required by the fire alarm control manufacturer 3 Current draw of NAC Slave input when connected as in figure 3 DESCRIPTION MDL3 Module is designed to work with the SpectrAlert Advance series notification appliances to provide a means of synchronizing the temporal horns and chimes synchronizing the one second flash timing of the and silencing the horns and chimes of the horn strobe and chime combination over a two wire circuit while leaving the strobes active is intended to connect to UL or ULC listed FACP or its NAC accessories a boost module etc MDL3 module can be configured so that more than two zones can synchronized by the interconnection of the slave input and output Figures 1 2 and 3 SPECTRALERT ADVANCE HORNS CHIMES AND STROBES Each module can power two 3 amp circuits wired in class B or one circuit powered as Class A Each module will synchronize 2 zones This manual shall be left with the owner user of this equipment CONFIGURATION MDL3 module has the capability of connecting two Style Y Class B or one Style Z Class A circuit zone output s from the panel are connected to the zone input s of the module and the zone output s from the MDL3 module are connected the notification loop s Supervision is accomplished in the module by a connection between the zone input and the zone output of each of the zone circuits connected to the normal end of line device The FACP EOL device through the MDL3 module When either or both outputs the module are wired to the SpectrAlert Advance products the horns or and strobes in both zones will be synchronized 1 Input 2 Input Control In input powers the MDL3 module This input must voltage present from the FACP before anything work This also supplies voltage to Zone 1 output input only supplies voltage to Zone 2 output If Zone 1 input is not powered the notification attached to the Zone 2 output will be out of input enables the horns on the SpectrAlert notification appliances Voltage present horns are enabled No voltage present means are disabled to Master MDL3 Module slave out A maxi of 11 slave MDL3 modules can be connected to a MDL3 Out to Slave MDL3 slave in Slave In to slave MDL3 from NAC A dedicated NAC be used for slaving purposes Additional modules can be added and may be synchronized to all other by interconnecting the input and output terminals modules SOUNDER ON OFF OVER 2 WIRES USING MODULE CONTROL Connect the current source to the horn control input If a zone output used for the source you must use an EOL on the horn control input see Figure 1 When multiple modules are used the horn control circuits can be wired parallel If wired in parallel and a zone output is used from panel use EOL on the last module for supervision it supervised Horn Control wiring must be contained within com enclosure of FACP Out Slave In wiring must be contained within either the common of modules or enclosures within 20 feet of each other with wiring conduit Reverse wiring will cause this input to malfunction Zone 1 input is not powered or fails during alarm the notification devices to the Zone 2 output will not be synchronized Ground fault on a module two wire loop can be indicated at the panel if the control panel is capable of ground fault detection on the supply to the module and meets UL 864 9th Edition ground fault in requirements for initiating device circuits The installer must verify capability 1 NAC slave wiring must be dedicated to sync purposes No devices be attached EOL must be used on the last MDL3 for supervision The value of EOL should refer to FACP specification or installation instruc 1 HORNS SILENCED OVER TWO WIRE CIRCUIT If zone 1 output of module is connected to strobes chime strobes or horn zone 1 input supply power must be continuous for proper operation MODULE HORN CONTROL CONNECTS TO INTERRUPTABLE POWER SOURCE 3 MASTER SLAVE USING NAC SLAVE INPUT If zone 1 is connected to synchronize other MDL3 no devices shall be to this zone Zone 1 input supply power must be continous to be 1 2 1 1 2 2 IN JUMP OFF NEXT DEVICE EOL 1 NEXT DEVICE EOL 1 NEXT MDL3 NAC IN OR EOL 1 STYLE Y ZONES B NEXT SPECTRALERT DEVICE OR EOL 1 1 2 1 1 2 2 IN JUMP OFF 4 WIRING FOR CODED SUPPLIES STROBE ONLY NEXT 1 NEXT EOL 1 CODE OUT Horn control must be powered for horn strobes to operate the horn portion SpectrAlert Advance horn only chime only and horn strobe or chime devices must be set to coded for multi code sourcing 5 6 MOUNTING DIAGRAM STRIPS 1 1 B 2 B 3 B 2 1 1 1 2 2 IN JUMP OFF 1 1 2 2 IN JUMP OFF NEXT DEVICE EOL 1 STYLE Y ZONES B NEXT DEVICE EOL 1 MUST BE WITH EITHER COMMON ENCLOSURE MODULES OR WITHIN 20 OF EACH OTHER WITH INSIDE CONDUIT NEXT DEVICE NEXT DEVICE Z ZONES A 2 MASTER SLAVE MODE If zone 1 output of module is connected to strobes chime strobes or horn zone 1 input supp

Related Files