Home » Fire-Lite 1400 2-Wire Smoke

File preview
Click the button below to download immediately for free
Download “Fire-Lite 1400 2-Wire Smoke” Fire-Lite_1400_2-Wire_Smoke.pdf – Downloaded 0 times – 735 KB
Show text preview
GENERAL System Sensor 1400 ionization smoke detector re- quickly to both fast flaming and slow smoldering as required by UL 268. The unipolar dual chamber has the sensitivity needed to quickly detect smoke, the stability needed to avoid false alarms. Detects both visible and invisible smoke. Used with UL listed control panels. Unipolar ionization sensing chamber: Provides exceptional stability. Factory preset 1.9% nominal sensitivity. Stable operation in air velocities up to 1,200 feet-per- (7.6 meters per second). Removable cover for field cleaning. Visible LED (cid:147)blinks(cid:148) in standby. Sealed against dirt, insects and back pressure. Three-year limited warranty. 8.5 – 35 VDC operating range. Field metering of detector sensitivity. Built-in test switch. Low standby current. Built-in tamper-resistant feature. Direct surface or electrical box mounting. Remote LED option. Insect-resistant screening (maximum to 0.020″/0.508 openings). SEMS screws for easy wiring. to contribute to life safety, fire protection, and property Superior to photoelectric detectors in de- fast-flaming fires. Superior to bipolar detectors in false alarms. AND OPERATION 1400 Series ionization smoke detectors contain a dual source, dual unipolar chamber detection de- which will sense the presence of smoke particles by fast combustion as well as slow smoldering Additional key features include a blinking LED status indicator, an easily visible alarm indica- and provision for convenient field test and metering. back of the detector is sealed to block back pressure flow. The chamber is protected by a fine mesh (0.020″/ mm) screen to minimize problems with dust, dirt, 19, 1998 Ionization Smoke Detector Conventional Initiating Devices Vol. III Fire insects. If cleaning is required, the cover is easily (with a special tool), providing access to the and chamber to perform a thorough cleaning. 1400 detectors are intended for use with Fire(cid:149)Lite listed control panels. Maximum number of detectors zone depends on capacity of panel (see Fire(cid:149)Lite De- Compatibility Document #15384). Easy to install and this detector is designed for direct surface (mounting bracket included), or mounting to a octagonal or smaller box.* Easy-to-wire screw termi- allow fast and simple field wiring of in, out, and re- annunciator connections. The wiring diagram (page shows the correct method for wiring Model 1400 detec- prevent wiring mistakes, observe polarities and make that each conductor is identified. A copy of the and maintenance instructions is packaged with detector. For further information, refer to NFPA 72 on Automatic Fire Detectors,(cid:148) and to local Au- Having Jurisdiction. For Canadian applications, always use a mounting elec- box. document is not intended to be used for installation purposes. We try to keep our information up-to-date and accurate. We cannot cover all specific applications or all requirements. All specifications are subject to change without notice. For information, contact Fire(cid:149)Lite. Phone: (203) 484-7161 FAX: (203) 484-7118 Clintonville Road, Northford, Connecticut 06472 and Manufacturing System Certified to Standard ISO-9001 in the U.S.A. (cid:151) Page 1 of 2 SPECIFICATIONS detector shall be an ionization type (Model 1400) manufactured by System Sensor. Wiring connections be made by means of SEMS screws. Detector will a visible LED which will blink in standby and latch on alarm. The detector shall have a sensitivity of 1.9 as measured in the UL smoke box. The detector and cover should be easily removable for clean- It shall be possible to perform a sensitivity and func- test on
GENERAL System Sensor 1400 ionization smoke detector re- quickly to both fast flaming and slow smoldering as required by UL 268. The unipolar dual chamber has the sensitivity needed to quickly detect smoke, the stability needed to avoid false alarms. Detects both visible and invisible smoke. Used with UL listed control panels. Unipolar ionization sensing chamber: Provides exceptional stability. Factory preset 1.9% nominal sensitivity. Stable operation in air velocities up to 1,200 feet-per- (7.6 meters per second). Removable cover for field cleaning. Visible LED (cid:147)blinks(cid:148) in standby. Sealed against dirt, insects and back pressure. Three-year limited warranty. 8.5 – 35 VDC operating range. Field metering of detector sensitivity. Built-in test switch. Low standby current. Built-in tamper-resistant feature. Direct surface or electrical box mounting. Remote LED option. Insect-resistant screening (maximum to 0.020″/0.508 openings). SEMS screws for easy wiring. to contribute to life safety, fire protection, and property Superior to photoelectric detectors in de- fast-flaming fires. Superior to bipolar detectors in false alarms. AND OPERATION 1400 Series ionization smoke detectors contain a dual source, dual unipolar chamber detection de- which will sense the presence of smoke particles by fast combustion as well as slow smoldering Additional key features include a blinking LED status indicator, an easily visible alarm indica- and provision for convenient field test and metering. back of the detector is sealed to block back pressure flow. The chamber is protected by a fine mesh (0.020″/ mm) screen to minimize problems with dust, dirt, 19, 1998 Ionization Smoke Detector Conventional Initiating Devices Vol. III Fire insects. If cleaning is required, the cover is easily (with a special tool), providing access to the and chamber to perform a thorough cleaning. 1400 detectors are intended for use with Fire(cid:149)Lite listed control panels. Maximum number of detectors zone depends on capacity of panel (see Fire(cid:149)Lite De- Compatibility Document #15384). Easy to install and this detector is designed for direct surface (mounting bracket included), or mounting to a octagonal or smaller box.* Easy-to-wire screw termi- allow fast and simple field wiring of in, out, and re- annunciator connections. The wiring diagram (page shows the correct method for wiring Model 1400 detec- prevent wiring mistakes, observe polarities and make that each conductor is identified. A copy of the and maintenance instructions is packaged with detector. For further information, refer to NFPA 72 on Automatic Fire Detectors,(cid:148) and to local Au- Having Jurisdiction. For Canadian applications, always use a mounting elec- box. document is not intended to be used for installation purposes. We try to keep our information up-to-date and accurate. We cannot cover all specific applications or all requirements. All specifications are subject to change without notice. For information, contact Fire(cid:149)Lite. Phone: (203) 484-7161 FAX: (203) 484-7118 Clintonville Road, Northford, Connecticut 06472 and Manufacturing System Certified to Standard ISO-9001 in the U.S.A. (cid:151) Page 1 of 2 SPECIFICATIONS detector shall be an ionization type (Model 1400) manufactured by System Sensor. Wiring connections be made by means of SEMS screws. Detector will a visible LED which will blink in standby and latch on alarm. The detector shall have a sensitivity of 1.9 as measured in the UL smoke box. The detector and cover should be easily removable for clean- It shall be possible to perform a sensitivity and func- test on