Home » Fire-Lite 5600(A) Series Mechanical Heat Detectors
_Series_Mechanical_Heat_Detectors_preview.jpg)
File preview
Click the button below to download immediately for free
Show text preview
5600 (A) Series Heat Detectors Sensor 5600 Series mechanical heat detectors offer protection against fire and for non-life-safety installa- where smoke detectors are inappropriate. configurations. The 5600 Series offers a full line of to accommodate a broad range of applications. single- and dual-circuit models are offered, each avail- for low- and high-temperature ratings with either fixed- or combination activation. The ROR element of the fixed/ROR models restorable, to accommodate field-testing the unit. flexibility. To satisfy a variety of installations, the Series easily mounts to single-gang and octagonal back- These models also accommodate 4″ (101.6 mm) backboxes when used with a plastic ring. The mounting is reversible to allow for flush- and surface-mount installations. identification. The 5600 Series provides clear mark- on the exterior of the unit to ensure that the proper detec- is being used. Alphanumeric characters identify the method, as well as the temperature rating, in Fahrenheit and Celsius. Fixed temperature models identified while combination fixed/rate-of-rise units marked The 5600 Series also provides a col- as a post-activation indicator. Once the detector has activated, the collector drops from the unit to allow easy of the specific unit in alarm. Multiple configurations available: Fixed-temperature (non-resettable) or combination fixed (self-restoring). Low-temperature and high-temperature ratings. Single-circuit and dual-circuit. Easy-to-read alphanumeric identification of detector type temperature rating. External collector provides visual indication of activation. Reversible mounting bracket for flush- and surface-mount Flexible mounting capabilities: single-gang, 3.5″ or 4″ octag- 4″ (101.6 mm) square with plastic ring. LISTINGS AND APPROVALS listings and approvals apply to the modules specified in document. In some cases, certain modules or applications not be listed by certain approval agencies, or listing may in process. Consult factory for latest listing status. UL Listed: S2101 ULC Listed: S2101 (Add suffix for Canadian part num- except 5601P) MEA: 199-03-E CSFM: 7270-1209:227, 7270-1653:167 FM Approved Initiating Devices SPECIFICATIONS installation temperature: models 5601, 5601P, 5603, 5621, 5623: 100 (38 for A models 5602, 5604, 5622, 5624: 150 (65.6 for A suf- temperature: models 5601, 5601P, 5603, 5621, 5623: 135 (57 models 5602, 5604, 5622, 5624: 194 (90 Threshold: 15 (8.3 per minute (models 5601P, 5602, 5621, 5622 only). Humidity Range: 5% to 95% RH noncondensing. Terminals: non-polarized, accept 14 to 22 AWG (2.0 to mm diameter with mounting bracket: 4.57″ (116 mm); with mounting bracket: 1.69″ (43 mm). 6 oz. (170 grams). Options: 3.5″ (88.9 mm) octagonal backbox; 4″ mm) octagonal backbox; single-gang backbox; 4″ mm) square backbox with a square-to-round plaster – 125 VAC – 28 VDC VDC VDC A A A A heat detector shall be a System Sensor 5600 model number ______, Listed to Underwriters Labora- UL 521 for Heat Detectors for Fire Protective Signaling The detector shall be either a single-circuit or a dual- type, normally open. The detector shall be rated for acti- at either 135 (57 or 194 (90 and shall acti- by means of a fixed-temperature thermal sensor, or a sensor. rate-of-rise element shall be activated by a rapid rise in 08/27/14 Page 1 of 2 Easy-to-use terminal screws provide a more positive wiring SPECIFICATIONS Low-profile design to coordinate with room aesthetics. Voltage Ratings (re
5600 (A) Series Heat Detectors Sensor 5600 Series mechanical heat detectors offer protection against fire and for non-life-safety installa- where smoke detectors are inappropriate. configurations. The 5600 Series offers a full line of to accommodate a broad range of applications. single- and dual-circuit models are offered, each avail- for low- and high-temperature ratings with either fixed- or combination activation. The ROR element of the fixed/ROR models restorable, to accommodate field-testing the unit. flexibility. To satisfy a variety of installations, the Series easily mounts to single-gang and octagonal back- These models also accommodate 4″ (101.6 mm) backboxes when used with a plastic ring. The mounting is reversible to allow for flush- and surface-mount installations. identification. The 5600 Series provides clear mark- on the exterior of the unit to ensure that the proper detec- is being used. Alphanumeric characters identify the method, as well as the temperature rating, in Fahrenheit and Celsius. Fixed temperature models identified while combination fixed/rate-of-rise units marked The 5600 Series also provides a col- as a post-activation indicator. Once the detector has activated, the collector drops from the unit to allow easy of the specific unit in alarm. Multiple configurations available: Fixed-temperature (non-resettable) or combination fixed (self-restoring). Low-temperature and high-temperature ratings. Single-circuit and dual-circuit. Easy-to-read alphanumeric identification of detector type temperature rating. External collector provides visual indication of activation. Reversible mounting bracket for flush- and surface-mount Flexible mounting capabilities: single-gang, 3.5″ or 4″ octag- 4″ (101.6 mm) square with plastic ring. LISTINGS AND APPROVALS listings and approvals apply to the modules specified in document. In some cases, certain modules or applications not be listed by certain approval agencies, or listing may in process. Consult factory for latest listing status. UL Listed: S2101 ULC Listed: S2101 (Add suffix for Canadian part num- except 5601P) MEA: 199-03-E CSFM: 7270-1209:227, 7270-1653:167 FM Approved Initiating Devices SPECIFICATIONS installation temperature: models 5601, 5601P, 5603, 5621, 5623: 100 (38 for A models 5602, 5604, 5622, 5624: 150 (65.6 for A suf- temperature: models 5601, 5601P, 5603, 5621, 5623: 135 (57 models 5602, 5604, 5622, 5624: 194 (90 Threshold: 15 (8.3 per minute (models 5601P, 5602, 5621, 5622 only). Humidity Range: 5% to 95% RH noncondensing. Terminals: non-polarized, accept 14 to 22 AWG (2.0 to mm diameter with mounting bracket: 4.57″ (116 mm); with mounting bracket: 1.69″ (43 mm). 6 oz. (170 grams). Options: 3.5″ (88.9 mm) octagonal backbox; 4″ mm) octagonal backbox; single-gang backbox; 4″ mm) square backbox with a square-to-round plaster – 125 VAC – 28 VDC VDC VDC A A A A heat detector shall be a System Sensor 5600 model number ______, Listed to Underwriters Labora- UL 521 for Heat Detectors for Fire Protective Signaling The detector shall be either a single-circuit or a dual- type, normally open. The detector shall be rated for acti- at either 135 (57 or 194 (90 and shall acti- by means of a fixed-temperature thermal sensor, or a sensor. rate-of-rise element shall be activated by a rapid rise in 08/27/14 Page 1 of 2 Easy-to-use terminal screws provide a more positive wiring SPECIFICATIONS Low-profile design to coordinate with room aesthetics. Voltage Ratings (re