Home » Fire-Lite ANN-80 Annunciator Datasheet

File preview
Click the button below to download immediately for free
Show text preview
ANN-80 Serial LCD Annunciator ANN-80 annunciator is a compact, backlit, 80-character LCD annunciator that mimics the Fire Alarm Control Panel (FACP) It provides system status indicators for AC Power, Alarm, Supervisory, and Alarm Silenced conditions. The ANN-80 the FACP communicate over a two-wire serial interface employ- the ANN-Bus communication format. Connected devices are via two additional wires, by either the host FACP or a UL-listed, filtered power supply. The ANN-80 is red; for order ANN-80-W. ANN-80 displays English-language text of system point informa- including device type, zone, independent point alarm, trouble or status, as well as any custom alpha labels programmed the control panel. It includes control switches for remote control critical system functions. (A keyswitch prevents unauthorized of the control switches.) to eight ANN-80s may be connected to the ANN-Bus of each No programming is required, which saves time during system Listed to UL Standard 864, 9th Edition Backlit 80-character LCD display (20 characters x 4 lines) Mimics all display information from the host panel Control switches for System Acknowledge, Signal Silence, Drill, Reset Control switches can be independently enabled or disabled at the Keyswitch enables/disables control switches and mechanically annunciator enclosure Keyswitch can be enabled or disabled at the FACP Enclosure supervised for tamper System status LEDs for AC Power, Alarm, Trouble, Supervisory, Alarm Silence Local sounder can be enabled or disabled at the FACP ANN-80 connects to the ANN-Bus terminal on the FACP and minimal panel programming Displays device type identifiers, individual point alarm, trouble, zone, and custom alpha labels Time-and date display field Surface mount directly to wall or to single, double, or 4″ square box Semi-flush mount to single, double, or 4″ square electrical box. ANN-SB80KIT for angled view mounting Can be remotely located up to 6,000 feet (1,800 m) from the Backlight turns off during AC loss to conserve battery power but turn back on if an alarm condition occurs May be powered by 24 VDC from the host FACP or by remote supply (requires 24 VDC) Up to eight ANN-80s can be connected on the ANN-Bus and Indicators AC Power Alarm Trouble B-90 Supervisory Alarm Silenced Operating voltage range: 18 VDC to 28 VDC Current consumption @ 24 VDC nominal (filtered and non- 40 mA maximum Ambient temperature: 32 to 120 (0 to 49 Relative humidity: 93% 2% RH (non-condensing) at 32 5.375 (13.65 cm.) high x 6.875 (17.46 cm.) wide x 1.375 (3.49 (90 3 deep For use indoors in a dry location All connections are power-limited and supervised ANN-Bus THE DEVICES ON THE ANN-BUS FROM AUXIL- POWER SUPPLY ANN-Bus can be powered by an auxiliary power supply when maximum number of ANN-Bus devices exceeds the ANN-Bus requirements. See the FACP manual for more information. DEVICE ADDRESSING ANN-Bus device requires a unique address (ID Number) in to communicate with the FACP. A maximum of 8 devices can connected to the FACP ANN-Bus communication circuit. See the manual for more information. REQUIREMENTS: COMMUNICATIONS CIRCUIT ANN-80 connects to the FACP ANN-Bus communications cir- To determine the type of wire and the maximum wiring distance can be used with FACP ANN-Bus accessory modules, it is nec- to calculate the total worst case current draw for all modules a single 4-conductor bus. The total worst case current draw is by adding the individual worst case currents for each For total worst case current draw on a single ANN-Bus refer to FACP manual. 3/15/2018 Page 1 of 2 REQUIREMENTS: POWER CIRCUI
ANN-80 Serial LCD Annunciator ANN-80 annunciator is a compact, backlit, 80-character LCD annunciator that mimics the Fire Alarm Control Panel (FACP) It provides system status indicators for AC Power, Alarm, Supervisory, and Alarm Silenced conditions. The ANN-80 the FACP communicate over a two-wire serial interface employ- the ANN-Bus communication format. Connected devices are via two additional wires, by either the host FACP or a UL-listed, filtered power supply. The ANN-80 is red; for order ANN-80-W. ANN-80 displays English-language text of system point informa- including device type, zone, independent point alarm, trouble or status, as well as any custom alpha labels programmed the control panel. It includes control switches for remote control critical system functions. (A keyswitch prevents unauthorized of the control switches.) to eight ANN-80s may be connected to the ANN-Bus of each No programming is required, which saves time during system Listed to UL Standard 864, 9th Edition Backlit 80-character LCD display (20 characters x 4 lines) Mimics all display information from the host panel Control switches for System Acknowledge, Signal Silence, Drill, Reset Control switches can be independently enabled or disabled at the Keyswitch enables/disables control switches and mechanically annunciator enclosure Keyswitch can be enabled or disabled at the FACP Enclosure supervised for tamper System status LEDs for AC Power, Alarm, Trouble, Supervisory, Alarm Silence Local sounder can be enabled or disabled at the FACP ANN-80 connects to the ANN-Bus terminal on the FACP and minimal panel programming Displays device type identifiers, individual point alarm, trouble, zone, and custom alpha labels Time-and date display field Surface mount directly to wall or to single, double, or 4″ square box Semi-flush mount to single, double, or 4″ square electrical box. ANN-SB80KIT for angled view mounting Can be remotely located up to 6,000 feet (1,800 m) from the Backlight turns off during AC loss to conserve battery power but turn back on if an alarm condition occurs May be powered by 24 VDC from the host FACP or by remote supply (requires 24 VDC) Up to eight ANN-80s can be connected on the ANN-Bus and Indicators AC Power Alarm Trouble B-90 Supervisory Alarm Silenced Operating voltage range: 18 VDC to 28 VDC Current consumption @ 24 VDC nominal (filtered and non- 40 mA maximum Ambient temperature: 32 to 120 (0 to 49 Relative humidity: 93% 2% RH (non-condensing) at 32 5.375 (13.65 cm.) high x 6.875 (17.46 cm.) wide x 1.375 (3.49 (90 3 deep For use indoors in a dry location All connections are power-limited and supervised ANN-Bus THE DEVICES ON THE ANN-BUS FROM AUXIL- POWER SUPPLY ANN-Bus can be powered by an auxiliary power supply when maximum number of ANN-Bus devices exceeds the ANN-Bus requirements. See the FACP manual for more information. DEVICE ADDRESSING ANN-Bus device requires a unique address (ID Number) in to communicate with the FACP. A maximum of 8 devices can connected to the FACP ANN-Bus communication circuit. See the manual for more information. REQUIREMENTS: COMMUNICATIONS CIRCUIT ANN-80 connects to the FACP ANN-Bus communications cir- To determine the type of wire and the maximum wiring distance can be used with FACP ANN-Bus accessory modules, it is nec- to calculate the total worst case current draw for all modules a single 4-conductor bus. The total worst case current draw is by adding the individual worst case currents for each For total worst case current draw on a single ANN-Bus refer to FACP manual. 3/15/2018 Page 1 of 2 REQUIREMENTS: POWER CIRCUI