ANN-RLY Module ANN-RLY relay module provides 10 programmable Form-C when used with a compatible FACP (Fire Alarm Control The ANN-RLY module may be mounted inside the FACP circuit board chassis or in the battery area of the enclosure optional mounting bracket P/N: ANN-MBRLY. Reference Instructions document #53033. ANN-RLY and the FACP communicate over a two-wire serial employing the ANN-Bus communication format. An addi- two wires are used for 24-volt DC power. A single four-con- unshielded cable may be used for both power and data to eight ANN-Bus devices may be connected to the ANN-Bus of FACP. ANN-RLY connects to the ANN-Bus terminal on the FACP and minimal programming Provides 10 programmable Form-C relays Ten Form-C relays can be programmed for various functions; Trouble, Supervisory, AC Loss, Waterflow Delay, Input and Silenceable Alarm. Compatible with ES-200X, ES-50X, MS9600(UD)LS, MS-9050UD, MRP-2001, MRP-2002, MS-10UD, MS-5UD May be powered by 24 VDC from the host FACP or by remote supply (requires 24 VDC) Up to eight ANN-Bus devices may be connected to the ANN-Bus each FACP Listed to UL Standard 864, 9th Edition Maximum ANN-BUS Voltage: 24 VDC Maximum Current: Alarm: 75 mA Standby: 15 mA Ambient Temperature: 32 to 120 (0 to 49 Relative Humidity: 93% 2% RH (non-condensing) at 32 2 3 For use indoors in a dry location Connections to FACP are power-limited and supervised. Relay Contact Ratings: 2 Amps @ 30VDC (Resistive) 0.5 Amps 30VAC (Resistive) ANN-Bus THE DEVICES ON THE ANN-BUS FROM AUXIL- POWER SUPPLY devices can be powered by an auxiliary power supply available panel power is exceeded. See FACP manual for DEVICE ADDRESSING ANN-Bus device requires a unique address (ID Number) in to communicate with the FACP. A maximum of eight devices be connected to the FACP ANN-Bus communication circuit. See FACP manual for more information. B-200 Information ANN-RLY: Relay Module provides 10 programmable Form C ANN-MBRLY: Optional mounting bracket; required for applications ROME: Relay Option Module Enclosure, includes one ANN-RLY module and one ANN-MBRLY bracket installed Listings and Approvals listings and approvals below apply to the FeaturedProduct. In cases, certain modules may not be listed by certain approval or listing may be in process. Consult factory for latest list- status. UL:S2424 FM Approved Fire Dept. of New York: #COA 6177 CSFM: 7120-0075:0222 MEA: 333-07-E 3/15/2018 Page 1 of 2 Alarms is a registered trademark of Honeywell International Inc. by Honeywell International Inc. All rights reserved. Unauthorized use of this is strictly prohibited. document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. cannot cover all specific applications or anticipate all requirements. specifications are subject to change without notice. 2 of 2 DF-52431:C 3/15/2018 more information, contact Fire Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. of Origin: USA
ANN-RLY Module ANN-RLY relay module provides 10 programmable Form-C when used with a compatible FACP (Fire Alarm Control The ANN-RLY module may be mounted inside the FACP circuit board chassis or in the battery area of the enclosure optional mounting bracket P/N: ANN-MBRLY. Reference Instructions document #53033. ANN-RLY and the FACP communicate over a two-wire serial employing the ANN-Bus communication format. An addi- two wires are used for 24-volt DC power. A single four-con- unshielded cable may be used for both power and data to eight ANN-Bus devices may be connected to the ANN-Bus of FACP. ANN-RLY connects to the ANN-Bus terminal on the FACP and minimal programming Provides 10 programmable Form-C relays Ten Form-C relays can be programmed for various functions; Trouble, Supervisory, AC Loss, Waterflow Delay, Input and Silenceable Alarm. Compatible with ES-200X, ES-50X, MS9600(UD)LS, MS-9050UD, MRP-2001, MRP-2002, MS-10UD, MS-5UD May be powered by 24 VDC from the host FACP or by remote supply (requires 24 VDC) Up to eight ANN-Bus devices may be connected to the ANN-Bus each FACP Listed to UL Standard 864, 9th Edition Maximum ANN-BUS Voltage: 24 VDC Maximum Current: Alarm: 75 mA Standby: 15 mA Ambient Temperature: 32 to 120 (0 to 49 Relative Humidity: 93% 2% RH (non-condensing) at 32 2 3 For use indoors in a dry location Connections to FACP are power-limited and supervised. Relay Contact Ratings: 2 Amps @ 30VDC (Resistive) 0.5 Amps 30VAC (Resistive) ANN-Bus THE DEVICES ON THE ANN-BUS FROM AUXIL- POWER SUPPLY devices can be powered by an auxiliary power supply available panel power is exceeded. See FACP manual for DEVICE ADDRESSING ANN-Bus device requires a unique address (ID Number) in to communicate with the FACP. A maximum of eight devices be connected to the FACP ANN-Bus communication circuit. See FACP manual for more information. B-200 Information ANN-RLY: Relay Module provides 10 programmable Form C ANN-MBRLY: Optional mounting bracket; required for applications ROME: Relay Option Module Enclosure, includes one ANN-RLY module and one ANN-MBRLY bracket installed Listings and Approvals listings and approvals below apply to the FeaturedProduct. In cases, certain modules may not be listed by certain approval or listing may be in process. Consult factory for latest list- status. UL:S2424 FM Approved Fire Dept. of New York: #COA 6177 CSFM: 7120-0075:0222 MEA: 333-07-E 3/15/2018 Page 1 of 2 Alarms is a registered trademark of Honeywell International Inc. by Honeywell International Inc. All rights reserved. Unauthorized use of this is strictly prohibited. document is not intended to be used for installation purposes. We try to keep our product information up-to-date and accurate. cannot cover all specific applications or anticipate all requirements. specifications are subject to change without notice. 2 of 2 DF-52431:C 3/15/2018 more information, contact Fire Alarms. Phone: (800) 627-3473, FAX: (877) 699-4105. of Origin: USA