Wiring + NEXT IDC Pull Station 50964 Manual Pull Station U.S. Patent No. Des. 428,351; 6,380,846; Other Patents Pending 2 3 4 GAUGE 50964 BG-12L pull station is a non-coded, dual-action manual pull station with a key-lock feature. It provides Fire control panels with one normally open (N/O) alarm initi- input. The BG-12L meets the ADAAG controls and operating mechanisms guidelines 4.1.3[13]), and the ADA requirement for a 5 lb. maximum pull force to activate pull station. Operating instructions are molded into the pull station handle along with text. Molded Terminal numbers are also present. contact (N/O) is gold plated for reliability and rated at 0.25 A at 30 volts (AC or BG-12L pull station can be surface mounted to an SB-10 or SB-I/O surface backbox semi-flush mounted on a standard single-gang, double-gang or 4 (10.16 cm) square box. The optional BG-TR trim ring can be used if the BG-12L is to be semi-flush activate the dual-action pull station, push in and pull down on the handle. The word appears after the handle is pulled down. This will remain until the pull sta- is reset. pull station includes one Single Pole, Single Throw (SPST) Normally Open (N/O) which closes upon activation of the pull station. the Pull Station Insert the key into the lock and rotate 1/4 turn counterclockwise. Open the door until the handle returns to normal. Close and lock the door. Closing the door automatically resets the switch to the position. Opening door will not activate or deactivate the alarm switch. DO NOT LOOP WIRING ANY TERMINALS. BREAK WIRE TO MAINTAIN IDC SUPERVISION. Do not loop wiring under any Break wire run to IDC supervision. Do not detach the door of the pull station during installation. The door of pull station cannot be reattached to the backplate after the backplate has already been onto an electrical box. the Fire BG-12L pull station in accordance with these instructions, NFPA standards, national and local Fire and Electrical codes and the requirements the AHJ (Authority Having Jurisdiction). Regular testing of the devices should be con- in accordance with the appropriate NFPA standards. Failure to follow these directions result in failure of the device to report an alarm condition. Fire is not responsible for that have been improperly installed, tested or maintained. Compliance ADA compliance, if the clear floor space only allows forward approach to an object, the forward reach height allowed is 48 inches (121.92 cm). If the clear floor space parallel approach by a person in a wheelchair, the maximum side reach allowed is inches (137.16 cm). + EL IDC 2 3 4 GAUGE Estaci Pulsadora Manual U.S. Patent No. Des. 428,351; 6,380,846; Other Patents Pending 50964 estaci pulsadora BG-12L es una estaci no c y de doble acci manual con caracter de reajuste de una cerradura de llave. Esta provee a los paneles de control Fire-Lite con una alarma de iniciaci de entrada normalmente abierta (N/O). El BG-12L las normas de control y funcionamiento de la ADAAG ( seccion 4.1.3 [13] ) y los de ADA para que la estaci pulsadora sea activada con una fuerza de jale m 5 libras. Las instrucciones de funcionamiento estan moldeadas en la manija (manubrio) al texto Braille. Los n moldeados de las terminales tambien estan presentes. de Contacto del Interruptor contacto del interruptor (N/O) es oro plateado para la confiabilidad y clasificado en 0.25 en 30 voltios (AV o DC). estaci pulsadora BG-12L puede ser montada en la superficie del respaldo de un SB- o un SB-1/O; esta tambi puede ser semi-montada en una caja el cuadrada ya individual o doble de 4 (10.16 cm). El anillo opcional (BG-TR) puede ser usado si el
Wiring + NEXT IDC Pull Station 50964 Manual Pull Station U.S. Patent No. Des. 428,351; 6,380,846; Other Patents Pending 2 3 4 GAUGE 50964 BG-12L pull station is a non-coded, dual-action manual pull station with a key-lock feature. It provides Fire control panels with one normally open (N/O) alarm initi- input. The BG-12L meets the ADAAG controls and operating mechanisms guidelines 4.1.3[13]), and the ADA requirement for a 5 lb. maximum pull force to activate pull station. Operating instructions are molded into the pull station handle along with text. Molded Terminal numbers are also present. contact (N/O) is gold plated for reliability and rated at 0.25 A at 30 volts (AC or BG-12L pull station can be surface mounted to an SB-10 or SB-I/O surface backbox semi-flush mounted on a standard single-gang, double-gang or 4 (10.16 cm) square box. The optional BG-TR trim ring can be used if the BG-12L is to be semi-flush activate the dual-action pull station, push in and pull down on the handle. The word appears after the handle is pulled down. This will remain until the pull sta- is reset. pull station includes one Single Pole, Single Throw (SPST) Normally Open (N/O) which closes upon activation of the pull station. the Pull Station Insert the key into the lock and rotate 1/4 turn counterclockwise. Open the door until the handle returns to normal. Close and lock the door. Closing the door automatically resets the switch to the position. Opening door will not activate or deactivate the alarm switch. DO NOT LOOP WIRING ANY TERMINALS. BREAK WIRE TO MAINTAIN IDC SUPERVISION. Do not loop wiring under any Break wire run to IDC supervision. Do not detach the door of the pull station during installation. The door of pull station cannot be reattached to the backplate after the backplate has already been onto an electrical box. the Fire BG-12L pull station in accordance with these instructions, NFPA standards, national and local Fire and Electrical codes and the requirements the AHJ (Authority Having Jurisdiction). Regular testing of the devices should be con- in accordance with the appropriate NFPA standards. Failure to follow these directions result in failure of the device to report an alarm condition. Fire is not responsible for that have been improperly installed, tested or maintained. Compliance ADA compliance, if the clear floor space only allows forward approach to an object, the forward reach height allowed is 48 inches (121.92 cm). If the clear floor space parallel approach by a person in a wheelchair, the maximum side reach allowed is inches (137.16 cm). + EL IDC 2 3 4 GAUGE Estaci Pulsadora Manual U.S. Patent No. Des. 428,351; 6,380,846; Other Patents Pending 50964 estaci pulsadora BG-12L es una estaci no c y de doble acci manual con caracter de reajuste de una cerradura de llave. Esta provee a los paneles de control Fire-Lite con una alarma de iniciaci de entrada normalmente abierta (N/O). El BG-12L las normas de control y funcionamiento de la ADAAG ( seccion 4.1.3 [13] ) y los de ADA para que la estaci pulsadora sea activada con una fuerza de jale m 5 libras. Las instrucciones de funcionamiento estan moldeadas en la manija (manubrio) al texto Braille. Los n moldeados de las terminales tambien estan presentes. de Contacto del Interruptor contacto del interruptor (N/O) es oro plateado para la confiabilidad y clasificado en 0.25 en 30 voltios (AV o DC). estaci pulsadora BG-12L puede ser montada en la superficie del respaldo de un SB- o un SB-1/O; esta tambi puede ser semi-montada en una caja el cuadrada ya individual o doble de 4 (10.16 cm). El anillo opcional (BG-TR) puede ser usado si el