Wiring IN/OUT ( IN/OUT (+) Pull Station 50964-2 Manual Pull Station U.S. Patent No. Des. 428,351; 6,380,846; 6,314,772 50964-2 BG-12S pull station is a non-coded, single-action manual pull station with pigtail con- and a hex-lock reset feature. It provides Fire control panels with one normally (N/O) alarm initiating input. The BG-12S meets the ADAAG controls and operating guidelines (section 4.1.3[13]), and the ADA requirement for a 5 lb. maximum force to activate the pull station. Operating instructions are molded into the pull station along with Braille text. contact (N/O) is gold plated for reliability and rated at 0.25 A at 30 volts (AC or BG-12S pull station can be surface mounted to an SB-10 or SB-I/O surface backbox semi-flush mounted on a standard single-gang, double-gang or 4 (10.16 cm) square box. The optional BG-TR trim ring can be used if the BG-12S is to be semi-flush activate the single-action pull station, simply pull down the handle. The word appears after the handle is pulled down. This will remain until the pull station is pull station includes one Single Pole, Single Throw (SPST) Normally Open (N/O) which closes upon activation of the pull station. the Pull Station To reset the BG-12S hex lock pull station, insert the supplied 9/64-inch hex wrench the lock until firmly seated and turn counterclockwise 1/4-turn. Open the door until the handle returns to normal. Close and lock the door. Closing the door automatically resets the switch to the position. Opening door will not activate or deactivate the alarm switch. Do not detach the door of the pull station during installation. The door of pull station cannot be reattached to the backplate after the backplate has already been onto an electrical box. the Fire BG-12S pull station in accordance with these instructions, NFPA standards, national and local Fire and Electrical codes and the requirements the AHJ (Authority Having Jurisdiction). Regular testing of the devices should be con- in accordance with the appropriate NFPA standards. Failure to follow these directions result in failure of the device to report an alarm condition. Fire is not responsible for that have been improperly installed, tested or maintained. Compliance ADA compliance, if the clear floor space only allows forward approach to an object, the forward reach height allowed is 48 inches (121.92 cm). If the clear floor space parallel approach by a person in a wheelchair, the maximum side reach allowed is inches (137.16 cm). Estaci Pulsadora Manual U.S. Patent No. Des. 428,351; 6,380,846; 6,314,772 50964-2 estaci pulsadora BG-12S es una estaci no c y de acci manual individual conecciones entrelazadas y una caracter de reajuste de una cerradura hexagonal. provee a los paneles de control de Fire con una alarma de iniciaci de entrada abierta (N/O). El BG-12S reune las normas de control y funcionamiento de la ( seccion 4.1.3 [13] ) y los requisitos de ADA para que la estaci pulsadora sea con una fuerza de jale m de 5 libras. Las instrucciones de funcionamiento estan en la manija (manubrio) junto al texto Braille. de Contacto del Interruptor contacto del interruptor (N/O) es oro plateado para la confiabilidad y clasificado en 0.25 A 30 voltios (AV o DC). estaci pulsadora BG-12S puede ser montada en la superficie del respaldo de un SB-10 un SB-I/O; esta tambi puede ser semi-montada en una caja el cuadrada ya sea o doble de 4 (10.16 cm). El anillo opcional (BG-TR) puede ser usado si el BG-12 a ser semi-montado. activar la estaci pulsadora de acci individual, simplemente tire hacia abajo la manija La palabra aparecer despu que la manija haya sido tirada hacia Esta permanecer hasta que la estaci pulsado
Wiring IN/OUT ( IN/OUT (+) Pull Station 50964-2 Manual Pull Station U.S. Patent No. Des. 428,351; 6,380,846; 6,314,772 50964-2 BG-12S pull station is a non-coded, single-action manual pull station with pigtail con- and a hex-lock reset feature. It provides Fire control panels with one normally (N/O) alarm initiating input. The BG-12S meets the ADAAG controls and operating guidelines (section 4.1.3[13]), and the ADA requirement for a 5 lb. maximum force to activate the pull station. Operating instructions are molded into the pull station along with Braille text. contact (N/O) is gold plated for reliability and rated at 0.25 A at 30 volts (AC or BG-12S pull station can be surface mounted to an SB-10 or SB-I/O surface backbox semi-flush mounted on a standard single-gang, double-gang or 4 (10.16 cm) square box. The optional BG-TR trim ring can be used if the BG-12S is to be semi-flush activate the single-action pull station, simply pull down the handle. The word appears after the handle is pulled down. This will remain until the pull station is pull station includes one Single Pole, Single Throw (SPST) Normally Open (N/O) which closes upon activation of the pull station. the Pull Station To reset the BG-12S hex lock pull station, insert the supplied 9/64-inch hex wrench the lock until firmly seated and turn counterclockwise 1/4-turn. Open the door until the handle returns to normal. Close and lock the door. Closing the door automatically resets the switch to the position. Opening door will not activate or deactivate the alarm switch. Do not detach the door of the pull station during installation. The door of pull station cannot be reattached to the backplate after the backplate has already been onto an electrical box. the Fire BG-12S pull station in accordance with these instructions, NFPA standards, national and local Fire and Electrical codes and the requirements the AHJ (Authority Having Jurisdiction). Regular testing of the devices should be con- in accordance with the appropriate NFPA standards. Failure to follow these directions result in failure of the device to report an alarm condition. Fire is not responsible for that have been improperly installed, tested or maintained. Compliance ADA compliance, if the clear floor space only allows forward approach to an object, the forward reach height allowed is 48 inches (121.92 cm). If the clear floor space parallel approach by a person in a wheelchair, the maximum side reach allowed is inches (137.16 cm). Estaci Pulsadora Manual U.S. Patent No. Des. 428,351; 6,380,846; 6,314,772 50964-2 estaci pulsadora BG-12S es una estaci no c y de acci manual individual conecciones entrelazadas y una caracter de reajuste de una cerradura hexagonal. provee a los paneles de control de Fire con una alarma de iniciaci de entrada abierta (N/O). El BG-12S reune las normas de control y funcionamiento de la ( seccion 4.1.3 [13] ) y los requisitos de ADA para que la estaci pulsadora sea con una fuerza de jale m de 5 libras. Las instrucciones de funcionamiento estan en la manija (manubrio) junto al texto Braille. de Contacto del Interruptor contacto del interruptor (N/O) es oro plateado para la confiabilidad y clasificado en 0.25 A 30 voltios (AV o DC). estaci pulsadora BG-12S puede ser montada en la superficie del respaldo de un SB-10 un SB-I/O; esta tambi puede ser semi-montada en una caja el cuadrada ya sea o doble de 4 (10.16 cm). El anillo opcional (BG-TR) puede ser usado si el BG-12 a ser semi-montado. activar la estaci pulsadora de acci individual, simplemente tire hacia abajo la manija La palabra aparecer despu que la manija haya sido tirada hacia Esta permanecer hasta que la estaci pulsado