Free fire alarm PDF manuals, documents, installation instructions, and technical specifications.

Fire-Lite CERTIFICATE OF COMPLIANCE SEISMIC DESIGN OF NONSTRUCTURAL COMPONENTS AND SYSTEMS

Home » Fire-Lite CERTIFICATE OF COMPLIANCE SEISMIC DESIGN OF NONSTRUCTURAL COMPONENTS AND SYSTEMS
File preview

File preview

Click the button below to download immediately for free

Download “Fire-Lite CERTIFICATE OF COMPLIANCE SEISMIC DESIGN OF NONSTRUCTURAL COMPONENTS AND SYSTEMS” Fire-Lite_CERTIFICATE_OF_COMPLIANCE_SEISMIC_DESIGN_OF_NONSTRUCTURAL_COMPONENTS_AND_SYSTEMS.pdf – Downloaded 0 times – 724 KB


CERTIFICATE OF COMPLIANCE DESIGN OF NONSTRUCTURAL COMPONENTS AND SYSTEMS No. (Revision 2) Date: 11/30/2016 Parameters: nonstructural products (mechanical and/or electrical components) listed on this certificate are CERTIFIED1 FOR SEISMIC APPLICATIONS accordance with the following building code2 releases. 2000, IBC 2003, IBC 2006, IBC 2009, IBC 2012 following model designations, options, and accessories are included in this certification. Reference report number VMA-45894-01 as issued The VMC Group for a complete list of certified models, included accessories/options, and certified installation methods. Fire Alarm Control Panels above referenced equipment is APPROVED for seismic application when properly installed,3 used as intended, and contains a Seismic Label referencing this Certificate of Compliance4. As limited by the tabulated values, below grade, grade, and roof-level installations, in essential facilities, for life safety applications, and/or of equipment containing hazardous contents are permitted and included in certification with an Equipment Importance Factor assigned as IP=1.5. Seismic Design Levels <= 2.50 * g <= 0.0 at Grade) <= 2.00 * g <= 1.0 on Roof) Classes A, B, C, D, Seismic Risk Category I, II, III, IV, and Seismic Design Categories A, B, C, D, E, and F all covered under this certification, limited by the SDS value stated above. section 13.2.5 of the third printing of ASCE7-10, by deriving the horizontal test accelerations using SDS = 2.00 g and z/h = 1.0 deriving the vertical test accelerations using SDS = 2.50 g, all applications are acceptable for roof and grade installations where 2.50 g. Seismic Installation Methods to rigid wall Test of Active and Energized Components, Non-Active Components, and Equipment Structure: by successful seismic shake table testing at the nationally recognized University of California Berkeley Pacific Engineering Research Center under the witness of the Certified Seismic Qualification Agency, The VMC Testing was conducted in accordance with ICC-ES AC-156 to envelope the required response spectrum (RRS) of horizontal flexible acceleration (AFLEX) of 3.20 g and a rigid acceleration (ARIG) of 2.40 g. This test level to an SDS = 2.50 g with a z/h of 1.0. Functionality was verified before and after the shake test. of Design for Supports and Attachments to the Building: calculations and analysis of the equipment attachment to the building structure, the equivalent static force method was using the Seismic Design Acceleration, FP/WP,5 for Load Resistance Factored Design (LRFD) methods. This but is not limited to the unit anchoring requirements and external isolation calculations. Design Acceleration Equation, = 0.4 x (SDS=2.50 g) x (IP=1.5) x (aP/RP=0.417) x (1+2(z/h=1.0)) = 1.88 g is representative of the worst-case shake tested condition, as determined from Table 13.6-1 in ASCE/SEI7-05/10. Rev 0 1 of 3 OF COMPLIANCE DESIGN OF NONSTRUCTURAL COMPONENTS AND SYSTEMS Product Table: Number Fire Alarm Control Panel Fire Alarm Control Panel Remote Power Supply Remote Power Supply Remote Power Supply Remote Power Supply Chassis Remote Power Supply Chassis Remote Power Supply Box BB-17F Box BB-26 Fire Alarm Control Panel 3 Amp Fire Alarm Control Panel 7 Amp Control Panel Release Control Panel Fire Alarm Control Panel 3 Amp Fire Alarm Control Panel 7 Amp Addressable Fire Alarm Control Panel Addressable Fire Alarm Control Panel Addressable Fire Alarm Control Panel Addressable Fire Alarm Control Panel Command Center Panel Command Center Panel LOC Telephone Panel Paging Unit Microphone certification includes the unit and factory supplied accessories and options. The unit and included accessories and options shall be a design and factory supplies. The unit shall be installed and attached to the building structure per the manufacturer supplied seismic instructions. This certification exclud [/bg_collapse]