Home » Fire-Lite CRF-300-6

File preview
Click the button below to download immediately for free
Download “Fire-Lite CRF-300-6” Fire-Lite_CRF-300-6.pdf – Downloaded 0 times – 930 KB
Show text preview
CRF-300-6(A) Relay Control Module CRF-300-6 six-relay control module provides an fire alarm system with six Form-C relays. first module is addressed from 01 to 154 while the remain- modules are automatically assigned to the next five higher Provisions are included for disabling a maximum of unused modules. A single isolated set of dry relay con- is provided for each module address, which is capable of wired for either a normally-open or normally-closed The module allows the control panel to switch these on command. No supervision is provided for the con- circuit. CRF-300-6 module has panel-controlled green LED indi- The panel can cause the LEDs to blink, latch on, or off. Six addressable Form-C relay contacts Removable 12 AWG (3.25 mm to 18 AWG (0.9 mm plug- terminal blocks Status indicators for each point Unused addresses may be disabled Rotary address switches LiteSpeed or CLIP operation Mount one or two modules in a BB-2F cabinet (optional) Mount up to six modules on a CHS-6 chassis in a CAB-4 or BB-6F cabinet (optional) Mounting hardware included current: 1.45 mA (SLC current draw with all used; if some addresses are disabled, the standby decreases) current: 32 mA (assumes all six relays have been once and all six LEDs solid ON) range: 32 to 120 (0 to 49 10% to 93% non-condensing 6.8″ (17.27 cm) high x 5.8″ (14.73 cm) wide x (2.54 cm) deep weight: 1.1 lb. (0.5 kg) including packaging options: CHS-6 chassis, BB-6F cabinet, or BB-2F gauge: 12 AWG (3.25 mm to 18 AWG (0.9 mm SLC wiring resistance: 40 or 50 ohms, panel current: 30 mA/relay pulse (15.6 ms pulse duration), under panel control contact ratings: 30 VDC; 70.7 VAC E-930 Devices ratings: 3.0 A @ 30 VDC maximum, resistive, non-coded. 2.0 A @ 30 VDC maximum, resistive, coded. 1.0 A @ 30 VDC maximum, inductive (L/R = 2 ms), coded. 0.5 A @ 30 VDC maximum, inductive (L/R = 5 ms), coded. 0.9 A @ 110 VDC maximum, resistive, non-coded. 0.9 A @ 125 VAC maximum, resistive, non-coded. 0.7 A @ 70.7 VAC maximum, inductive (PF = 0.35), non- 0.3 A @ 125 VAC maximum, inductive (PF = 0.35), non- 1.5 A @25 VAC maximum, inductive (PF = 0.35), non- 2.0 A @25 VAC maximum, inductive (PF = 0.35), non- Listings and Approvals listings and approvals apply to the modules specified in document. In some cases, certain modules or applications not be listed by certain approval agencies, or listing may in process. Consult factory for latest listing status. UL Listed: S2424 ULC Listed: S2424 (CRF-300-6A) MEA Listed: 55-02-E CSFM: 7300-0075:0205 Maryland State Fire Marshall: Permit # 2099 FM Approved (Light Protective Signaling Only) 4/12/2016 Page 1 of 2 Line Information Six-relay control module Same as above with ULC Listing Optional cabinet for one or two modules. Dimensions, 9.234″ (23.454 cm) wide (9.484″ [24.089 cm] including x 12.218″ (31.0337 cm) high, x 0.672″ (1.7068 cm) BACKBOX: 9.0″ (22.860 cm) wide (9.25″ [23.495 cm] hinges), x 12.0″ (30.480 cm) high x 2.75″ (6.985 cm); (installed): 7.150″ (18.161 cm) wide overall x 7.312″ cm) high interior overall x 2.156″ (5.4762 cm) deep Optional cabinet for up to six modules mounted on chassis (below). Dimensions, DOOR: 24.0″ (60.96 cm) x 12.632″ (32.0852 cm) high, x 1.25″ (3.175 cm) deep, at bottom; BACKBOX: 24.0″ (60.96 cm) wide x 12.550″ cm) high x 5.218″ (13.2537 cm) deep Chassis, mounts up to six modules in a BB-6F cabi- is a trademark; and FireLite Alarms is a registered trademark Honeywell International Inc. by Honeywell International Inc. All rights reserved. Unauthorized use this document is strictly prohibited. document is not intended to be used for installation purposes. We try to keep our product informat
CRF-300-6(A) Relay Control Module CRF-300-6 six-relay control module provides an fire alarm system with six Form-C relays. first module is addressed from 01 to 154 while the remain- modules are automatically assigned to the next five higher Provisions are included for disabling a maximum of unused modules. A single isolated set of dry relay con- is provided for each module address, which is capable of wired for either a normally-open or normally-closed The module allows the control panel to switch these on command. No supervision is provided for the con- circuit. CRF-300-6 module has panel-controlled green LED indi- The panel can cause the LEDs to blink, latch on, or off. Six addressable Form-C relay contacts Removable 12 AWG (3.25 mm to 18 AWG (0.9 mm plug- terminal blocks Status indicators for each point Unused addresses may be disabled Rotary address switches LiteSpeed or CLIP operation Mount one or two modules in a BB-2F cabinet (optional) Mount up to six modules on a CHS-6 chassis in a CAB-4 or BB-6F cabinet (optional) Mounting hardware included current: 1.45 mA (SLC current draw with all used; if some addresses are disabled, the standby decreases) current: 32 mA (assumes all six relays have been once and all six LEDs solid ON) range: 32 to 120 (0 to 49 10% to 93% non-condensing 6.8″ (17.27 cm) high x 5.8″ (14.73 cm) wide x (2.54 cm) deep weight: 1.1 lb. (0.5 kg) including packaging options: CHS-6 chassis, BB-6F cabinet, or BB-2F gauge: 12 AWG (3.25 mm to 18 AWG (0.9 mm SLC wiring resistance: 40 or 50 ohms, panel current: 30 mA/relay pulse (15.6 ms pulse duration), under panel control contact ratings: 30 VDC; 70.7 VAC E-930 Devices ratings: 3.0 A @ 30 VDC maximum, resistive, non-coded. 2.0 A @ 30 VDC maximum, resistive, coded. 1.0 A @ 30 VDC maximum, inductive (L/R = 2 ms), coded. 0.5 A @ 30 VDC maximum, inductive (L/R = 5 ms), coded. 0.9 A @ 110 VDC maximum, resistive, non-coded. 0.9 A @ 125 VAC maximum, resistive, non-coded. 0.7 A @ 70.7 VAC maximum, inductive (PF = 0.35), non- 0.3 A @ 125 VAC maximum, inductive (PF = 0.35), non- 1.5 A @25 VAC maximum, inductive (PF = 0.35), non- 2.0 A @25 VAC maximum, inductive (PF = 0.35), non- Listings and Approvals listings and approvals apply to the modules specified in document. In some cases, certain modules or applications not be listed by certain approval agencies, or listing may in process. Consult factory for latest listing status. UL Listed: S2424 ULC Listed: S2424 (CRF-300-6A) MEA Listed: 55-02-E CSFM: 7300-0075:0205 Maryland State Fire Marshall: Permit # 2099 FM Approved (Light Protective Signaling Only) 4/12/2016 Page 1 of 2 Line Information Six-relay control module Same as above with ULC Listing Optional cabinet for one or two modules. Dimensions, 9.234″ (23.454 cm) wide (9.484″ [24.089 cm] including x 12.218″ (31.0337 cm) high, x 0.672″ (1.7068 cm) BACKBOX: 9.0″ (22.860 cm) wide (9.25″ [23.495 cm] hinges), x 12.0″ (30.480 cm) high x 2.75″ (6.985 cm); (installed): 7.150″ (18.161 cm) wide overall x 7.312″ cm) high interior overall x 2.156″ (5.4762 cm) deep Optional cabinet for up to six modules mounted on chassis (below). Dimensions, DOOR: 24.0″ (60.96 cm) x 12.632″ (32.0852 cm) high, x 1.25″ (3.175 cm) deep, at bottom; BACKBOX: 24.0″ (60.96 cm) wide x 12.550″ cm) high x 5.218″ (13.2537 cm) deep Chassis, mounts up to six modules in a BB-6F cabi- is a trademark; and FireLite Alarms is a registered trademark Honeywell International Inc. by Honeywell International Inc. All rights reserved. Unauthorized use this document is strictly prohibited. document is not intended to be used for installation purposes. We try to keep our product informat