Home » Fire-Lite IPDACT-2(UD) Dm 387-Iv3 Quick Start Programming Guide
_Dm_387-Iv3_Quick_Start_Programming_Guide_preview.jpg)
File preview
Click the button below to download immediately for free
Show text preview
Communicator Dm 387-Iv3 Start Programming Guide using a PC Serial Port TS563/2 Requirements Panel Id compatible panel with tone dialing. Existing PSTN Service (for backup communication lines). PC with RS-232 serial port. Console cable for the IPDACT-2(UD). Range (Maximum) 12VDC (Maximum) 24VDC VDC 180 mA (NSC), 230 mA (Alarm) 185 mA (NSC), 230 mA (Alarm) 93 mA (NSC), 136 mA (Alarm) 98 mA (NSC), 155 mA (Alarm) Access a static IP address (always the same) or a dynamic IP address (could be different every time connection is made) are possible. Checklist console access password (default is 24680). password, required to execute the register command. address, subnet mask and gateway for IPDACT-2(UD)2 account number or client number. address, and UDP Port number of the VisorALARM central station. Please obtain the following information from your central monitoring station. If you have a DHCP server in the network to which the IPDACT-2(UD) connects, these parameters can be obtained automatically. Physical Connections to the PRIMARY and SECONDARY FIRE PANEL PHONE LINE. connections to the TO AP terminal are interchangeable. voltage: -72 VDC current: 22 mA 600 be connected to supplied 1K resistors (factory installed). the power supply from the Fire Alarm Panel (or other electric a broadband modem/router or a network switch/hub for internet with a IEEE 802.3 interface. AP INPUT2 +12/24V Network IPDACT-2(UD) Default Configuration a short circuit in the IPDACT-2(UD) P1 jumper during the start up process, you can the IPDACT-2(UD) with the default factory settings. The process for this is as off the IPDACT-2(UD), circuit the jumper with the supplied berg header, on the device, maintain the jumper short circuited during the first A-D LEDs burst (the LEDs on and off) and undo the short circuit during the second burst. the process has executed successfully, the IPDACT-2(UD) will display a third burst the default configuration has been activated. Serial Port Programming order to use the serial port, you need to connect the cable designed to this end which must obtained either from Fire-Lite or from an authorized distributor. The following figures show cable and the connection mode to the IPDACT-2(UD). the serial cable to the IPDACT-2(UD) as shown above, the other end to a PC serial and use a terminal emulation program (Windows HyperTerminal for example) the serial port to 9600 bps, 8 data bits, 1 stop bit, without parity and no flow When you connect the terminal emulation program, you will be asked for a The factory default value is Enter this and the following menu will Accepted – Main Menu – Configuration a) Generic MIP config b) Transmission Parameters c) Quick Install Monitoring d) General Info e) Remote Monitor f) Events g) IP Connectivity z) Exit option: c — Quick Install — a) DHCP client: ON b) IP addr: 192.168.0.100 mask: 255.255.255.0 c) Gateway IP: 192.168.0.200 d) Account Number: 0 e) Supervisory Main: f) Supervisory Backup: g) Maintenance: h) Port: 80 i) Register MIP j) Reset k) AutoRegister MIP: z) Exit deals with an options menu where option is represented by a letter the title. Each option accesses a or contains a parameter value. select an option, enter this and press ENTER. device installation, access the Quick menu by pressing c and then figure will be presented. All the to install the device are found this menu. The steps to complete the are as follows: The menu displayed
Communicator Dm 387-Iv3 Start Programming Guide using a PC Serial Port TS563/2 Requirements Panel Id compatible panel with tone dialing. Existing PSTN Service (for backup communication lines). PC with RS-232 serial port. Console cable for the IPDACT-2(UD). Range (Maximum) 12VDC (Maximum) 24VDC VDC 180 mA (NSC), 230 mA (Alarm) 185 mA (NSC), 230 mA (Alarm) 93 mA (NSC), 136 mA (Alarm) 98 mA (NSC), 155 mA (Alarm) Access a static IP address (always the same) or a dynamic IP address (could be different every time connection is made) are possible. Checklist console access password (default is 24680). password, required to execute the register command. address, subnet mask and gateway for IPDACT-2(UD)2 account number or client number. address, and UDP Port number of the VisorALARM central station. Please obtain the following information from your central monitoring station. If you have a DHCP server in the network to which the IPDACT-2(UD) connects, these parameters can be obtained automatically. Physical Connections to the PRIMARY and SECONDARY FIRE PANEL PHONE LINE. connections to the TO AP terminal are interchangeable. voltage: -72 VDC current: 22 mA 600 be connected to supplied 1K resistors (factory installed). the power supply from the Fire Alarm Panel (or other electric a broadband modem/router or a network switch/hub for internet with a IEEE 802.3 interface. AP INPUT2 +12/24V Network IPDACT-2(UD) Default Configuration a short circuit in the IPDACT-2(UD) P1 jumper during the start up process, you can the IPDACT-2(UD) with the default factory settings. The process for this is as off the IPDACT-2(UD), circuit the jumper with the supplied berg header, on the device, maintain the jumper short circuited during the first A-D LEDs burst (the LEDs on and off) and undo the short circuit during the second burst. the process has executed successfully, the IPDACT-2(UD) will display a third burst the default configuration has been activated. Serial Port Programming order to use the serial port, you need to connect the cable designed to this end which must obtained either from Fire-Lite or from an authorized distributor. The following figures show cable and the connection mode to the IPDACT-2(UD). the serial cable to the IPDACT-2(UD) as shown above, the other end to a PC serial and use a terminal emulation program (Windows HyperTerminal for example) the serial port to 9600 bps, 8 data bits, 1 stop bit, without parity and no flow When you connect the terminal emulation program, you will be asked for a The factory default value is Enter this and the following menu will Accepted – Main Menu – Configuration a) Generic MIP config b) Transmission Parameters c) Quick Install Monitoring d) General Info e) Remote Monitor f) Events g) IP Connectivity z) Exit option: c — Quick Install — a) DHCP client: ON b) IP addr: 192.168.0.100 mask: 255.255.255.0 c) Gateway IP: 192.168.0.200 d) Account Number: 0 e) Supervisory Main: f) Supervisory Backup: g) Maintenance: h) Port: 80 i) Register MIP j) Reset k) AutoRegister MIP: z) Exit deals with an options menu where option is represented by a letter the title. Each option accesses a or contains a parameter value. select an option, enter this and press ENTER. device installation, access the Quick menu by pressing c and then figure will be presented. All the to install the device are found this menu. The steps to complete the are as follows: The menu displayed