MS-9050UD(E) Alarm Control Panel DACT Fire MS-9050UD(E) is a Fire Alarm Control Panel and Digital Alarm Communicator/Transmitter (DACT) into one circuit board. This compact, intelligent control panel supports up to 50 addressable of any type of detectors and modules. With an exten- list of powerful features, the MS-9050UD programs just like larger products, yet fits into applications previously only by conventional panels. MS-9050UD integral DACT transmits system status troubles, AC loss, etc.) to a Central Station via the pub- switched telephone network. It also allows remote and local of the control panel using the PK-CD Upload/ utility. In addition, the control panel may be pro- or interrogated off-site via the public switched tele- network. Any personal computer with Windows 95 or and compatible modem with a speed of 14.4 kbps or and Fire Upload/Download software kit PK-CD, may as a Service Terminal. This allows download of the entire or upload of the entire program, history file, walk-test current status and system voltages. power supply and all electronics are contained on a single board supported on a new quick install chassis and in a metal cabinet. Available accessories include local remote upload/download software, remote annunciators, reverse polarity/city box transmitter. (4XTMF) options include a UL listed printer, PRN-6F and the new Internet Monitoring module.The FireWatch Series inter- monitoring modules IPDACT-2 and IPDACT-2UD permit of alarm signals over the Internet, saving the monthly of two telephone lines. Although not required, the second- telephone line may be retained providing backup communi- over the public switched telephone line. Unless otherwise specified, the term MS-9050UD is used this data sheet to refer to both the MS-9050UD and the MS- FACPs. For MS-9050UDC, refer to DF-60445. Listed to UL Standard 864, 9th edition. Auto-program mode) two devices set to the same address. On-board DACT. Two independently programmable Style Z (Class A) or Style Selectable strobe synchronization for System Sensor, Whee- (Class B) NAC circuits. and Gentex devices. monitor modules. Remote Acknowledge, Silence, Reset and Drill via address- Two programmable relays and one fixed trouble relay. Built-in Programmer. Telephone Line Active LEDs. EIA-232 PC interface. Real-time clock/calendar with automatic daylight savings 80-character LCD display with backlighting. History file with 500 event capacity. Automatic detector sensitivity testing (NFPA 72 compliant). Automatic device type-code verification. A1-20 Point trouble identification. Waterflow selection per module point. Alarm verification selection per detector point. Maintenance alert warns when smoke detector dust accumu- is excessive. One-person audible or silent walk test with walk-test log and System alarm verification selection per detector point. PAS (Positive Alarm Sequence) and Pre-signal per point 72 compliant). Up to eight ANN-BUS annunciators Remote Acknowledge, Alarm Silence, Reset and Drill via modules or remote annunciator. Upload/Download (local or remote) of program and data via DACT. COMMUNICATION LOOP Single addressable SLC loop which meets NFPA Style 4, 6 7 requirements. 50 addressable device capacity (any combination of address- detectors and modules). Compatible with Fire addressable devices (refer to SLC Manual). APPLIANCE CIRCUITS (NACS) Two independently programmable output circuits. Circuits be configured for the following outputs: Style Y (Class B) Style Z (Class A) Door Holder Service (cannot be used for notification appliances) Aux Power Source (cannot be used for notification app
MS-9050UD(E) Alarm Control Panel DACT Fire MS-9050UD(E) is a Fire Alarm Control Panel and Digital Alarm Communicator/Transmitter (DACT) into one circuit board. This compact, intelligent control panel supports up to 50 addressable of any type of detectors and modules. With an exten- list of powerful features, the MS-9050UD programs just like larger products, yet fits into applications previously only by conventional panels. MS-9050UD integral DACT transmits system status troubles, AC loss, etc.) to a Central Station via the pub- switched telephone network. It also allows remote and local of the control panel using the PK-CD Upload/ utility. In addition, the control panel may be pro- or interrogated off-site via the public switched tele- network. Any personal computer with Windows 95 or and compatible modem with a speed of 14.4 kbps or and Fire Upload/Download software kit PK-CD, may as a Service Terminal. This allows download of the entire or upload of the entire program, history file, walk-test current status and system voltages. power supply and all electronics are contained on a single board supported on a new quick install chassis and in a metal cabinet. Available accessories include local remote upload/download software, remote annunciators, reverse polarity/city box transmitter. (4XTMF) options include a UL listed printer, PRN-6F and the new Internet Monitoring module.The FireWatch Series inter- monitoring modules IPDACT-2 and IPDACT-2UD permit of alarm signals over the Internet, saving the monthly of two telephone lines. Although not required, the second- telephone line may be retained providing backup communi- over the public switched telephone line. Unless otherwise specified, the term MS-9050UD is used this data sheet to refer to both the MS-9050UD and the MS- FACPs. For MS-9050UDC, refer to DF-60445. Listed to UL Standard 864, 9th edition. Auto-program mode) two devices set to the same address. On-board DACT. Two independently programmable Style Z (Class A) or Style Selectable strobe synchronization for System Sensor, Whee- (Class B) NAC circuits. and Gentex devices. monitor modules. Remote Acknowledge, Silence, Reset and Drill via address- Two programmable relays and one fixed trouble relay. Built-in Programmer. Telephone Line Active LEDs. EIA-232 PC interface. Real-time clock/calendar with automatic daylight savings 80-character LCD display with backlighting. History file with 500 event capacity. Automatic detector sensitivity testing (NFPA 72 compliant). Automatic device type-code verification. A1-20 Point trouble identification. Waterflow selection per module point. Alarm verification selection per detector point. Maintenance alert warns when smoke detector dust accumu- is excessive. One-person audible or silent walk test with walk-test log and System alarm verification selection per detector point. PAS (Positive Alarm Sequence) and Pre-signal per point 72 compliant). Up to eight ANN-BUS annunciators Remote Acknowledge, Alarm Silence, Reset and Drill via modules or remote annunciator. Upload/Download (local or remote) of program and data via DACT. COMMUNICATION LOOP Single addressable SLC loop which meets NFPA Style 4, 6 7 requirements. 50 addressable device capacity (any combination of address- detectors and modules). Compatible with Fire addressable devices (refer to SLC Manual). APPLIANCE CIRCUITS (NACS) Two independently programmable output circuits. Circuits be configured for the following outputs: Style Y (Class B) Style Z (Class A) Door Holder Service (cannot be used for notification appliances) Aux Power Source (cannot be used for notification app