Home » Fire-Lite MS-9600 (C_E) Addressable Fire Alarm Control Panel
_Addressable_Fire_Alarm_Control_Panel_preview.jpg)
File preview
Click the button below to download immediately for free
Show text preview
www.firelite.com Fire MS-9600 is a compact, cost-effective, intelli- addressable fire alarm control panel with a capacity of addressable Fire(cid:127)Lite devices on two loops (2nd loop A single Signaling Line Circuit (SLC) loop sup- up to 159 smoke detectors and 159 control or monitor The panel uses surface-mount technology and is for ease of installation and programming. It fea- the latest in advanced fire protection technology, in- maintenance alert and automatic detector test. Loop SLC can be configured for NFPA Style 4, 6, or 7 operation. Optional module for adding a second SLC loop (Part # SLC supports up to 318 addressable devices (159 detec- and 159 monitor, control, or relay modules), including new addressable heat detector, duct detector and dual module. SLC loop maximum length 10,000 ft. (3,048 m) @ 12 AWG mm2). Needs twisted, shielded wire. (3,000 ft. unshielded wire.) Appliance Circuits (NAC Two onboard NAC with additional NAC capability using control modules (CMF-300). Silence Inhibit and Auto Silence timer options. Continuous, March Time, Temporal or California code for circuit board NAC with two-stage capability. Selectable strobe synchronization per NAC. 6.0 amps total NAC power/7.2 amps total system power. and Software Auto-program (learn mode) reduces installation time. Fully programmable from local keypad, local PS-2 key- or PC via PK-9600UD Windows utility. Two-level user programmable passwords. Custom English labels per point may be manually entered selected from an internal library file. Two programmable Form-C relay outputs. 99 software zones. Interface Remote Acknowledge, Silence, Reset and Drill via addres- monitor modules, ACS-series annunciators or LCD- Remote annunciator. EIA-232 printer/PC interface (variable baud rate) on main board. 7, 2001 A1-200 (cid:27)(cid:17)(cid:19)(cid:20) Addressable S624 Integral 80-character LCD display with backlighting. Real-time clock/calendar with automatic daylight savings control. History file with 1,000-event capacity. EIA-485 supporting up to 32 ACS-series annunciators. EIA-485 supporting up to 32 LCD-80F annunciators. Fire Technology Sensitivity testing with printable results. Automatic drift compensation. Maintenance alert warns when smoke detector dust accu- is excessive. Automatic device type-code verification. One person audible or silent walk test with walk test log printout. Point trouble identification. document is not intended to be used for installation purposes. We try to our product information up-to-date and accurate. We cannot cover all spe- applications or anticipate all requirements. All specifications are subject to without notice. For more information, contact Fire(cid:127)Lite Alarms, One Fire- Place, Northford, Connecticut 06472. Phone: (800) 627-3473, Toll Free (877) 699-4105, FAX Back:(888) 388-3299 in the U.S.A. Page 1 of 4 (cid:2)(cid:4)(cid:16) “(cid:2)(cid:4)(cid:5)(cid:6)(cid:10)(cid:23)(cid:5)(cid:3)#(cid:23)$(cid:16)(cid:4)(cid:16)(cid:3)(cid:1) VDC E ALA RM ANN UNCIATOR Power Silenced tep ce o ld 2 sec. IA -485 Interface built the m otherboard w ires) VDC IA -485 in A C S ode (2 w ires) N N U N C IATO R S F M -LE D C S /A C M M VDC O ptional F orm -C 5 A m p R elays A C s (N otifica
www.firelite.com Fire MS-9600 is a compact, cost-effective, intelli- addressable fire alarm control panel with a capacity of addressable Fire(cid:127)Lite devices on two loops (2nd loop A single Signaling Line Circuit (SLC) loop sup- up to 159 smoke detectors and 159 control or monitor The panel uses surface-mount technology and is for ease of installation and programming. It fea- the latest in advanced fire protection technology, in- maintenance alert and automatic detector test. Loop SLC can be configured for NFPA Style 4, 6, or 7 operation. Optional module for adding a second SLC loop (Part # SLC supports up to 318 addressable devices (159 detec- and 159 monitor, control, or relay modules), including new addressable heat detector, duct detector and dual module. SLC loop maximum length 10,000 ft. (3,048 m) @ 12 AWG mm2). Needs twisted, shielded wire. (3,000 ft. unshielded wire.) Appliance Circuits (NAC Two onboard NAC with additional NAC capability using control modules (CMF-300). Silence Inhibit and Auto Silence timer options. Continuous, March Time, Temporal or California code for circuit board NAC with two-stage capability. Selectable strobe synchronization per NAC. 6.0 amps total NAC power/7.2 amps total system power. and Software Auto-program (learn mode) reduces installation time. Fully programmable from local keypad, local PS-2 key- or PC via PK-9600UD Windows utility. Two-level user programmable passwords. Custom English labels per point may be manually entered selected from an internal library file. Two programmable Form-C relay outputs. 99 software zones. Interface Remote Acknowledge, Silence, Reset and Drill via addres- monitor modules, ACS-series annunciators or LCD- Remote annunciator. EIA-232 printer/PC interface (variable baud rate) on main board. 7, 2001 A1-200 (cid:27)(cid:17)(cid:19)(cid:20) Addressable S624 Integral 80-character LCD display with backlighting. Real-time clock/calendar with automatic daylight savings control. History file with 1,000-event capacity. EIA-485 supporting up to 32 ACS-series annunciators. EIA-485 supporting up to 32 LCD-80F annunciators. Fire Technology Sensitivity testing with printable results. Automatic drift compensation. Maintenance alert warns when smoke detector dust accu- is excessive. Automatic device type-code verification. One person audible or silent walk test with walk test log printout. Point trouble identification. document is not intended to be used for installation purposes. We try to our product information up-to-date and accurate. We cannot cover all spe- applications or anticipate all requirements. All specifications are subject to without notice. For more information, contact Fire(cid:127)Lite Alarms, One Fire- Place, Northford, Connecticut 06472. Phone: (800) 627-3473, Toll Free (877) 699-4105, FAX Back:(888) 388-3299 in the U.S.A. Page 1 of 4 (cid:2)(cid:4)(cid:16) “(cid:2)(cid:4)(cid:5)(cid:6)(cid:10)(cid:23)(cid:5)(cid:3)#(cid:23)$(cid:16)(cid:4)(cid:16)(cid:3)(cid:1) VDC E ALA RM ANN UNCIATOR Power Silenced tep ce o ld 2 sec. IA -485 Interface built the m otherboard w ires) VDC IA -485 in A C S ode (2 w ires) N N U N C IATO R S F M -LE D C S /A C M M VDC O ptional F orm -C 5 A m p R elays A C s (N otifica