Free fire alarm PDF manuals, documents, installation instructions, and technical specifications.

Fire-Lite UOXX7

Home » Fire-Lite UOXX7
File preview

File preview

Click the button below to download immediately for free

Download “Fire-Lite UOXX7” Fire-Lite_UOXX7.S3705_Control_Unit_Accessories,_System_Certified_for_Canada.pdf – Downloaded 0 times – 591 KB


UOXX7.S3705 – Control Unit Accessories, System Certified for Canada Guide OD Home Contact Us ULC Home Unit Accessories, System Certified for Canada Unit Accessories, System Certified for Canada Bottom General Information for Control Unit Accessories, System Certified for Canada SENSOR UNINCORPORATED, DIV OF HONEYWELL INTERNATIONAL INC Ohio Ave Charles, IL 60174-5467 USA Module Model(s) CMF-300A, FCM-1, FRM-1, FTM-1A, JKM-FCM-1, JKM-FCM-1C modules Model(s) M500SA-FL (b), M500SA-NT (b) modules, 15-32 V dc, 6.5 mA max Model(s) M500SA (b), M500SA-HW (b) unit accessories Model(s) ECLIPS zone interfaces, rated 1A @ 15-32 V Model(s) M502MA-FCI Monitor Module Model(s) FDM-1, M500DMAP Model(s) DNRW of line relay modules, rating 9-40 V dc, 9-35 Vrms Model(s) EOLR-1A modules, rating 15-32 Vdc NS 500uA, alarm 3 mA and only compatible for connection only on the intelligent circuit of Secutron control unit, models MR-2100/2200 Model(s) M900MA Isolator Module Model(s) ISO-6A, rating DCL Communication 15-32 V dc, stand-by current 450 uA per circuit, 2.7 mA all active current in isolation, 17 mA per circuit, 102 mA all circuits. rating DCL Communication CCT 15-30 Vdc, stand-by current <150uA maximum protective voltage < 4V, reset voltage > 7V, current <13mA, this module is only compatible for connection only on the intelligent communication circuit of Secutron control models MR-2100/2200. isolator modules, 15-32 dc, 450 Ua Model(s) M500XA alarm equipment dual monitor modules Model(s) M500DMAPA phone control modules, rated 15-32 V dc, 5.0 mA max short circuit Model(s) M500FPA-FCI (b) phone control modules, supply voltage 15-32 V dc, 7.5 mA maximum, indicating circuit is rated as follows: 3 A, 24 V Model(s) FTM-1A, M500FPA, MIX-M500FPA modules, 24 V dc, 24 mA Model(s) M500DMR1A-FCI, M500DMR1A-FL, M500DMR1A-HW, M500DMR1A-NT Relay Module, 24 V dc, 0.35 mA Model(s) M900SRM modules, rating 15-32 Vdc NS 350uA, alarm 3 mA and only compatible for connection only on the intelligent circuit of Secutron control unit, models MR-2100/2200 Model(s) M902MA monitor modules, 15-32 V dc, 375 mA max Model(s) M501MA, MMF-301A modules Model(s) EM-1MMIA, Communication CCT 15-30 V dc 485 uA standby, 745 uA maximum alarm. output 5.4 V 2 mA max at short circuit current. monitor modules, 15-24 V dc, 5.2 mA max @ 15 V dc on alarm Model(s) M500DMA-FCI, M500DMA-FL and A monitor modules, 15-32 V dc, 5.1 mA max Model(s) M502MA-NT monitor modules, 24 V dc, 230 uA Model(s) M501MA-FCI, M501MA-FL, M501MA-HW Module Model(s) FMM-1, FMM-101, FZM-1, HFS-MM, HFS-MMA, JSM-FMM-1, JSM-FMM-101C, JSM-FMM-1C, KM-FZM-1C, 5:06:54 PM] - Control Unit Accessories, System Certified for Canada Module, for connection on the intelligent communication circuit of Model 9500 remote terminal unit by General and Model IRC-3, 24 V dc, 230 u Model(s) M500M, M500M-HW modules Model(s) EM-1MIA, rating Communication CCT 15-30 V dc 485 uA standby, 750 uA maximum alarm, output 5.4 V 2 mA max at short circuit current. M500MA-FCI, M500MA-FL, M500MA-NT, M500MAB-FL, M501MA-NT, M501RA-NT, M501SA-NT modules, 15-32 V dc, 5.1 mA Model(s) M502MA-HW modules, 15-32 V dc, 5.1 mA max Model(s) M500MA, M502MA, MMF-300A, MMF-302A modules, 15-32 V dc, 5.7 mA, compatible with Intelligent Communication Circuit Fire Alarm Control Unit by Fire- Alarm, Inc Model(s) MDF-300 modules, 24 V dc, 230 uA Model(s) M500DMA-HW, M500MA-HW cabinets, for house 2 multi-modules Model(s) BB-2 cabinets, for house up to 6 multi-modules Model(s) BB-6 module, system sensors, rating 15-32 V dc, 60 mA per circuit Model(s) EOLR-1A, IM-10A-FCI, IM-10A-FL module, system sensors, rating 15-32 V dc, 60 mA per circuit, compatible with Intelligent Communication Fire Alarm Control Unit by Mircom Technologies, Inc., model FX-2000 Model(s) IM-10A modules, rating 15-32 Vdc, 3.5 mA NS, 60 mA alarm Model(s) APIM-10A modules, system sensors, rating 15-32 V dc, 60 mA per circuit Model(s) IM-10A-NT modules, rating 15-32 Vdc, 1.45 mA NS, 37 mA alarm Model(s) APCR-6A six control module, system sensors Model(s) CR-6A, rating 15-32 V dc alarm and rating for relay contact 18-28 V dc, A max or 125 V ac @ 0 [/bg_collapse]