Fire-Lite 2412-2424 Smoke Detector

File Preview
File Preview
Click below to download for free

File Data

Name fire-lite-2412-2424-smoke-detector-3459260178.pdf
Type PDF
Size 801.80 KB
Downloads

Text Preview

June 22 1998 and 2424 Photoelectric Smoke Detectors Optional Horn Thermal Sensors Conventional Initiating Devices Vol III 2424 2424AIT 2424TH Fire 2424AT 2412THB 2424TH System Sensor 2400 Series photoelectric detector is designed to meet the stringent performance re of industrial and municipal fire detection and systems The design of these detectors emphasizes of installation and field maintenance 12 or 24 VDC operation Unique optical sensing chamber Superior signal to noise ratio Built in signal processing 3.0 nominal sensitivity Removable cover for field cleaning Visible LED cid 147 blinks cid 148 in standby latches on in alarm Sealed against dirt insects and back pressure Optional built in 135 cid 176 F 57 cid 176 C thermal Three year limited warranty Field metering of detector sensitivity Built in test capability Low standby current Twist on mounting bracket with tamper option Designed for direct surface or electrical box mounting Models available with built in 85 dBA piezoelectric horn Insect resistant screening with 0.020 0.508 mm open Isolated or integrated operation of thermal available cer models SEMS screws for easy wiring Meets performance criteria designated by UL 268 Built to withstand air velocities up to 3,000 feet 914.4 per minute without triggering a false alarm to contribute to life safety fire protection and property Photoelectric detectors are recommended areas where smoldering fires are likely to ignite In ar where small combustion particles are usually present forklift trucks cooking stoves etc they are less likely ionization detectors to produce false alarms further information see System Sensor manual I56 cid 147 Applications Manual for System Smoke Detectors cid 148 provides detailed information on detector spacing zoning wiring and special applications AND OPERATION 2400 Series photoelectric smoke detectors contain a optical sensing chamber designed to sense the of smoke particles produced by a wide range of sources A custom integrated circuit incorpo signal processing to reduce false alarms and sample circuitry to provide easy field metering of sensitivity optional built in piezo horn produces an interrupted 85 tone at 10 feet 3.048 m The horn operates upon reversal of the supply voltage when the unit senses or when the thermal reaches its alarm point inte thermal models only document is not intended to be used for installation purposes We try to keep our information up to date and accurate We cannot cover all specific applications or all requirements All specifications are subject to change without notice For information contact Fire cid 149 Lite Phone 203 484 7161 FAX 203 484 7118 Clintonville Road Northford Connecticut 06472 and Manufacturing System Certified to Standard ISO 9001 in the U S A cid 151 Page 1 of 3 to install and maintain these detectors are designed direct surface mounting mounting bracket included mounting to a 4 101.6 mm octagon or smaller box screw terminals allow fast and simple field of in out and remote annunciator connections control panel specifications for the maximum al loop resistance for the particular control panel to used prevent wiring mistakes observe polarities and make that each conductor is identified Installation and instructions are packaged with each detec For further information refer to NFPA 72 Standards the local authority having jurisdiction detectors are designed to seal the sensing cham from back pressure air flow dust dirt and insects The of each detector is sealed The chamber is protected a fine mesh 0.020 0.508 mm screen Installation and Instructions are packaged with each detec SPECIFICATIONS smoke detector shall be a photoelectric type models and 2424 or a combination photoelectric thermal type 2412TH and 2424TH with thermal sensor rated 135 cid 176 F 57 cid 176 C as manufactured by System Sensor Wir connections shall be made by means of SEMS screws detector will have a visible LED which will blink in and latch on in alarm The sensor shall have a sensitivity of 3.0 per foot as measured In a UL box The detector screen and cover should be eas removable for cleaning It shall be possible to perform a and functional test on the detector without need to generate smoke Detector circuitry shall perform a on the sensing chamber and internal electronics 40 seconds If circuitry fails the detector LED shall blinking The detector LED shall stop blinking The shall have a mounting bracket that allows for di surface mounting or mounting to a 3 1 2 88.9 mm 4 101.6 mm octagonal box SPECIFICATIONS 2 of 3 cid 151 DF 50529 DIAGRAMS LINE INFORMATION photoelectric detector direct wire 12 with horn and integral 135 cid 176 F 57 cid 176 C fixed photoelectric detector direct wire 12 Four wire photoelectric detector direct wire 12 with integral 135 cid 176 F 57 cid 176 C fixed thermal photoelectric detector direct wire 24 photoelectric detector direct wire 24 with horn and isolated thermal built in and 85 dBA horn photoelectric detector direct wire 24 with horn and integral 135 cid 176 F 57 cid 176 C fixed photoelectric detector direct wire 24 integral 135 cid 176 F 57 cid 176 C fixed thermal Annunciator LED Field Test Module cid 151 Page 3 of 3

Related Files