Fire-Lite AD365(-IV) Multi-Criteria Detector Manual
File Preview
Click below to download for free
Click below to download for free
File Data
Name | fire-lite-ad365-iv-multi-criteria-detector-manual-5674328091.pdf |
---|---|
Type | |
Size | 1.17 MB |
Downloads |
Text Preview
INSTALLATION AND MAINTENANCE INSTRUCTIONS and AD365 IV Photoelectric and Infrared Sensor Voltage Range Current 24 VDC Alarm Current Current Humidity Range Temperature Range Velocity Load Rating refer to your isolator base module manual for isolator calculation instructions to 32 VDC uA one communication every 5 seconds with green LED blink on communication mA 24 VDC one communication every 5 seconds with red LED solid on mA 24 VDC one communication every 5 seconds with amber LED solid on to 90 Relative Humidity Non condensing to 100 0 to 38 to 300 ft min 0 to 91.4 m min 51 mm installed in B300 6 Base 156 mm installed in B300 6 Base 4.1 104 mm installed in B501 Series Base oz 95 g FireLite Place CT 06472 203.484.7161 268 listed for Open Air Protection 268A listed for Duct Applications 521 listed for Heat Detectors sensor must be installed in compliance with the control panel installation manual The installation must meet the require of the Authority Having Jurisdiction AHJ Sensors offer maxi performance when compliance with the National Protection Association NFPA see NFPA 72 For a complete list compatible bases refer to the Base Sensor Cross Reference Chart at DESCRIPTION AD365 and AD365 IV are plug in type multi criteria smoke sensors that a photoelectric sensing chamber combined with a 135 57.2 fixed heat detector and infrared IR sensors The AD365 and AD365 IV transmit an alarm signal due to heat 135 per UL 521 sensors transmit an analog representation of smoke density over a commu line to a control panel Rotary dial switches are provided for setting sensor address See Figure 2 LEDs on the sensor are controlled by the panel to indicate sensor status output is provided for connection to an optional remote LED annunciator RA100Z panels offer different features sets across different models As a result features of the photoelectric sensors may be available on some control but not on others will support only LiteSpeed protocol mode AD365 IV will support ei LiteSpeed or CLIP Classic Loop Interface Protocol mode The possible available in the multi criteria smoke sensors if supported by the con unit are The sensor LEDs can operate in three ways off and blinking can be set to red green or amber This is controlled by the panel The remote output may be synchronized to the LED operation or con independent of the LEDs Devices are point addressable up to 159 addresses refer to the operation manual for the UL listed control panel for specific The photoelectric sensors require compatible addressable com to function properly Connect these sensors to listed compatible panels only recommends spacing sensors in compliance with NFPA 72 In low air applications with smooth ceilings space sensors 30 feet apart 9.1 m specific information regarding sensor spacing placement and special ap refer to NFPA 72 or the System Smoke Detector Application Guide from FireLite GUIDE wiring must be installed in compliance with the National Electrical Code local codes and any special requirements of the Authority Having Proper wire gauges should be used The installation wires should color coded to limit wiring mistakes and ease system troubleshooting connections will prevent a system from responding properly in the of a fire power from the communication line before installing sensors Wire the sensor base supplied separately per the base wiring diagram Figure 1 Set the desired address on the sensor address switches See Figure 2 Install the sensor into the sensor base Push the sensor into the base while it clockwise to secure it in place After all sensors have been installed apply power to the control panel and the communication line Test the sensor s as described in the TESTING section of this manual 1 WIRING DIAGRAM A OPTIONAL WIRING not loop wire under terminal 1 or 2 Break wire run to provide supervision connections 2 ROTARY ADDRESS SWITCHES 0 0 3 FEATURES OF THE PTIR DETECTOR Alignment Notch Test Point C2050 00 4 CLEANING THE PTIR DETECTOR Cover Chamber and Screen a Put the device into test mode by holding a test magnet in the magnet area as shown in Figure 3 for 6 12 seconds NOTE If the magnet is held in place for too long the fire alarm test func will be triggered See Magnet Test above Reset the panel and pro with testing the smoke entry portion of the device b Perform smoke entry testing immediately following the magnet test The test initiates an approximately 10 minute period when the detec signal processing software routines are not active in test mode test the smoke detector using one of the tested and ap aerosol smoke products Refer to the manufacturer published instruc for proper use of the canned smoke agent When used properly the smoke agent will cause the smoke detector to go into alarm and approved aerosol smoke products include Fire and Safety Climb 30S PURCHECK CENTURION SOLO A10 TRUTEST SOLO 365 2000 C2044 00 covers provide limited protection against airborne dust particles dur shipping Dust covers must be removed before the sensors can sense CO sensors prior to heavy remodeling or construction RESISTANCE AD365 and AD365 IV include a tamper resistant capability that pre removal from the base without the use of a tool Refer to the base man for details on making use of this capability testing notify the proper authorities that the system is undergoing and will temporarily be out of service Disable the system to unwanted alarms sensors must be tested after installation and periodically thereafter Test methods must satisfy the Authority Having Jurisdiction AHJ Sensors maximum performance when tested and maintained in compliance with 72 Sensitivity readings are available through the FACP Refer to the turer published instructions for proper use sensor can be tested in the following ways Functional Magnet Test P N M02 04 01 or M02 09 00 This sensor can be functionally tested with a test magnet The test magnet simulates smoke in the sensing chamber testing the sensor and connections to the control panel Hold the test magnet in the magnet test area as shown in Figure 3 The sensor should alarm the panel aerosol simulated smoke canned smoke agent formulas will vary manufacturer Misuse or overuse of these products may have long term effects on the smoke detector Consult the canned smoke agent manu published instructions for any further warnings or caution statements Direct Heat Method Hair Dryer of 1000 1500 watts A hair dryer of 1000 1500 watts should be used to test the thermistors Di the heat toward the thermistor holding the heat source approximately inches 30 cm from the detector in order to avoid damaging the plastic The detector will reset only after it has had sufficient time to Make sure both thermistors are tested individually Multi Criteria Testing Testifire by SDi provides testing of the smoke and heat sensors Consult the published instructions for complete usage instructions sensor that fails any of these tests may need to be cleaned as described CLEANING and retested When testing is complete restore the system normal operation and notify the proper authorities that the system is back operation removing the detector notify the proper authorities that the smoke system is u