Fire-Lite BEAM355 and BEAM355S
File Preview
Click below to download for free
Click below to download for free
File Data
Name | fire-lite-beam355-and-beam355s-4506193872.pdf |
---|---|
Type | |
Size | 746.30 KB |
Downloads |
Text Preview
BEAM355 and BEAM355S Reflected Type Beam Smoke Detectors FireLite BEAM355 and BEAM355S are reflected beam smoke detectors for protecting areas with high and sloping ceilings and wide open where spot type smoke detectors are difficult to install maintain applications are atriums cathedral aircraft hangars warehouses sporting arenas halls and enclosed parking facilities They are with the MS 9600 Series and MS9200 Series in or CLIP mode Installation of the single ended design is much quicker than a dual ended projected detector Alignment is easily accomplished with an sight and a two digit signal strength meter incorporated the beam detector Listed for operation from to the BEAM355 and BEAM355S are usable in open area where temperature extremes exceed the design of other types of smoke detection BEAM355 and BEAM355S are a transmitter receiver unit a reflector When smoke enters the area between the unit the reflector it causes a reduction in the signal strength threshold an alarm is activated The detectors four standard sensitivity selections as well as two settings When either Acclimate setting is detector advanced software algorithms adjust to the optimum sensitivity for the specific BEAM355S has an integral sensitivity test feature of a attached to a servomotor inside the detector optics of the RTS151 or RTS151KEY remote test stations the filter into the pathway of the light beam testing the sensitivity This sensitivity test feature allows the to quickly and easily meet the annual maintenance and requirements of NFPA 72 without physical access to the The servomotor must be powered by 24 VDC not power strength smoke Listed to UL 268 ULC CAN ULC S529 Transmitter receiver built into same unit Six user selectable sensitivity levels 16 to 328 use BEAMLRK beyond 230 protection range Removable plug in terminal blocks Digital display no special tools required Built in automatic gain control compensates for signal dete from dust buildup Optional remote test station Optional long range kit BEAMLRK for applications in of 230 70 m Optional multi mount kit BEAMMMK providing ceiling or mount capability with increased angular adjustment Optional heater kits BEAMHK and BEAMHKR of condensation not intended to increase or the specified operating temperature Paintable cover E 270 Devices Plate SPECIFICATIONS Range 16 to 230 feet 5 to 70 m 230 to 328 feet to 100 m using optional BEAMLRK kit Angle horizontal and vertical Note that optics move independently of the unit 6 levels Sensitivity settings are a feature of specific control panels Level 1 25 Level 2 30 Level 3 40 Level 4 50 Acclimate Level 5 30 to 50 Acclimate Level 6 40 to 50 Condition trouble 96 or more obscuration blockage Self compensation limit reached Aid Optical gunsight Two digit display Alarm local red LED and remote alarm Trouble local yellow LED and remote trouble Normal local flashing green LED alignment mode initial alignment signal strength indication 11 16 09 Page 1 of 4 features sensitivity test filter BEAM355S only requires power supply Sensitivity filter incremental scale on reflector Local alarm test switch Local alarm reset switch Remote test and reset switch compatible with RTS151 and test stations Detector Spacing On smooth ceilings 30 60 feet to 18.3 m between projected beams and not more than that spacing between a projected beam and a Other spacing may be used depending on ceiling airflow characteristics and response requirements NFPA 72 SPECIFICATIONS to 131 to 55 10 93 RH noncondensing SPECIFICATIONS Voltage 15 to 32 VDC Average Standby Current 24 VDC 2 mA maximum flashing SLC 24 V Alarm Current LED on 8.5 mA maximum Trouble Current LED on 4.5 mA maximum Alignment Current 20 mA maximum External Supply BEAM355S only 15 to 32 VDC 0.5 A maximum Remote Output Alarm 15 to 32 VDC Output voltage same as device voltage 15 mA maximum 6 mA minimum Output current limited by 2.2K ohm resistor Heater Kit BEAMHK Voltage 15 to 32 V Current 92 mA 32 V heater only Power Consumption 1.6 W 24 V maximum 3.0 W 32 V Reflector Heater Kit BEAMHKR Voltage 15 to 32 V 450 mA maximum 32 V per reflector Power per reflector nominal 7.7 W 24 V 15.0 W 32 V SPECIFICATIONS Weight 3.7 lbs 1.68 kg Dimensions 10.0 H x 7.5 W x 3.3 D 254 mm H x mm W x 84 mm D Dimensions 7.9 x 9.1 200 x 230 mm Dimensions for Applications Beyond 230 x 18.1 400 x 460 mm 70m 230 16 SELECTION detector has six sensitivity selections sensitivity settings a feature of specific control panels Each of these only acceptable over a specific distance between the detector and the reflector per UL 268 chart below determines which selections are acceptable your installed distance The sensitivity of the detector can set only when the housing is removed and the detector is in the fine adjustment step of the alignment mode by the illumination of the dual digital display To set sensitivity depress the sensitivity button one time See Locations diagram Once the switch is pressed the display will illuminate and read the current sensitivity in percent obscuration To change the sensitivity to depress the sensitivity switch until the desired off if no further switch presses occur achieved The digital display will to 200 to 50 to 50 to 120 5.0 to 36.6 to 45.7 to 150 to 67 to 220 to 328 to 100 to 150 24.4 to 45.7 1 2 3 4 1 2 addition to the four standard sensitivity selections the has two Acclimate settings When either Acclimate is chosen the detector will automatically adjust its using advanced software algorithms to select the sensitivity for the environment The sensitivity will be adjusted within the ranges specified in the chart obscuration can be converted to percent per foot uniform smoke density for the entire length of the The chart below converts total obscuration percent per for all acceptable sensitivity settings to 67 2 of 4 DF 52408 B 11 16 09 Obscuration 1 2 4 3 5 only for electrical Panel or Previous Line VDC Maximum pair is Diagram Next Alarm Out Input Input RTS151 KEY Installation Instructions electrical ratings of the RTS151 KEY