Fire-Lite BG-12 Series
File Preview
Click below to download for free
Click below to download for free
File Data
Name | fire-lite-bg-12-series-1708453962.pdf |
---|---|
Type | |
Size | 666.08 KB |
Downloads |
Text Preview
BG 12 Series Fire Alarm Pull Stations Fire BG 12 Series is a cost effective feature packed of non coded manual fire alarm pull stations It was to meet multiple applications with the installer and in mind The BG 12 Series features a variety of mod including single and dual action versions BG 12 Series provides Fire Alarm Control Panels as well as other manufacturers controls with a man alarm initiating input signal Its innovative design durable and multiple mounting options make the BG 12 simple to install maintain and operate Aesthetically pleasing highly visible design and color Attractive contoured shape and light textured finish Meets ADA 5 lb maximum pull force Meets UL 38 Standard for Manually Actuated Signaling Boxes Easily operated single or dual action yet designed to pre false alarms when bumped shaken or jarred PUSH IN PULL DOWN handle latches in the down position to indicate the station has been operated The word appears on top of the handle in yellow further indicating operation of the station Operation handle features white arrows showing basic opera direction for non English speaking persons Braille text included on finger hold area of operation handle across top of handle Multiple hex and key lock models available U S patented hex lock needs only a quarter turn to lock Station can be opened for inspection and maintenance with initiating an alarm Product ID label viewable by simply opening the cover label made of a durable long life material The words and are molded into the adjacent to the alarm switch located inside Four position terminal strip molded into backplate Terminal strip includes Phillips combination head captive 8 32 for easy connection to Initiating Device Circuit IDC Terminal screws backed out at factory and shipped ready to field wiring up to 12 AWG 3.1 mm Terminal numbers are molded into the backplate eliminating need for labels Switch contacts are normally open Can be surface mounted with SB 10 or SB I O or semi mounted Semi flush mount to a standard single gang or 4 10.16 cm square electrical box Backplate is large enough to overlap a single gang backbox by 1 2 1.27 cm Optional trim ring BG12TR Spanish versions FUEGO available BG 12LSP BG 12LPSP Designed to replace the Fire legacy BG 10 Series Models packaged in attractive clear plastic PVC clam Point of Purchase packages Packaging includes cutaway dust paint cover in shape of pull station cid 129 F 050 Initiating Devices Cover backplate and operation handle are all molded of polycarbonate material Cover features white lettering and trim Red color matches System Sensor popular SpectrAlert horn strobe series BG 12 manual pull stations provide a textured finger hold that includes Braille text In addition to PUSH IN and PULL text there are arrows indicating how to operate the sta provided for non English speaking people in and then pulling down on the handle activates the alarm switch Once latched in the down position word appears at the top in bright yellow with a of the handle protruding at the bottom as a visible flag the station is simple insert the key twist one quarter then open the station front cover causing the spring operation handle to return to its original position The switch can then be reset to its normal non alarm position by hand or by closing the station front cover which resets the switch 04 22 08 Page 1 of 2 SPECIFICATIONS station inches cm inches cm inches cm inches cm inches cm inches cm inches cm inches cm inches cm SPECIFICATIONS contact ratings gold plated rating 0.25 A 30 VAC or SPECIFICATIONS Fire Alarm Stations shall be non code with a key or reset lock in order that they may be tested and so that after actual Emergency Operation they cannot be to normal except by use of a key or hex An operated shall automatically condition itself so as to be visually as activated Manual stations shall be constructed of colored LEXAN or polycarbonate equivalent with clearly operating instructions provided on the cover The word shall appear on the front of the stations in white letters inches 2.54 cm or larger Stations shall be suitable for mounting on matching backbox SB 10 or SB I O or mounting on a standard single gang double gang or 10.16 cm square electrical box and shall be installed within limits defined by the Americans with Disabilities Act ADA or national local requirements Manual Stations shall be Under Laboratories listed The words on the BG 12LSP shall appear the front of the station in white letters approximately 3 4 cm high Listings and Approvals listings and approvals below apply to the BG 12 Series pull In some cases certain modules may not be listed by approval agencies or listing may be in process Consult for latest listing status C UL US S711 FM Approved CSFM 7150 0075 184 MEA 67 02 E Patented U S Patent No D428,351 6,380,846 6,314,772 Line Information Single action pull station with pigtail connections hex Same as BG 12 with key lock Dual action pull station with SPST N O switch screw connections hex lock Same as BG 12 with key lock Same as BG 12L with English Spanish FIRE labeling Same as BG 12L with use listing outdoor listed backbox and sealing gasket Same as BG 12L with use listing Does include backbox Same as BG 12L with auxiliary contacts Dual action pull station with pre signal option Same as BG 12LPS with English Spanish FIRE labeling Surface mount backbox metal Surface mount backbox plastic Included with BG Optional trim ring for semi flush mounting Keys set of two Included with key lock pull stations Hex lock 9 64 Included with hex lock pull stations For addressable BG 12LX models see data sheet DF Alarms SpectrAlert Advance and System Sensor are trademarks of Honeywell International Inc by Honeywell International Inc All rights reserved Unauthorized use this document is strictly prohibited document is not intended to be used for installation purposes We try to keep our product information up to date and accurate cannot cover all specific applications or anticipate all requirements specifications are subject to change without notice more information contact Fire cid 129 Lite Alarms Phone 800 627 3473 FAX 877 699 4105 in the U S A 2 of 2 DF 52004 A1 cid 129 04 22 08