Fire-Lite BG-12LA Manual Pull Station
File Preview
Click below to download for free
Click below to download for free
File Data
Name | fire-lite-bg-12la-manual-pull-station-1835976402.pdf |
---|---|
Type | |
Size | 1.06 MB |
Downloads |
Text Preview
Wiring FACP To Next Device IDC Contact Contact Pull Station 51381 Manual Pull Station U S Patent No Des 428,351 6,380,846 Other Patents Pending 51381 2 3 4 BG 12LA pull station is a non coded dual action manual pull station with a key lock feature It provides Fire control panels with one normally open N O alarm initiat input A second set of contacts is rated up to 3 Amps at 30 V AC or DC for auxiliary The BG 12LA meets the ADAAG controls and operating mechanisms guidelines 4.1.3 13 and the ADA requirement for a 5 lb maximum pull force to activate pull station Operating instructions are molded into the pull station handle along with text Molded Terminal numbers are also present Circuit Terminals 1 2 to 25 Amp at 30 Volts AC or DC Contact Circuit Terminals 3 4 to 3 Amps at 30 Volts AC or DC BG 12LA pull station can be surface mounted to an SB 10 or SB I O surface backbox semi flush mounted on a standard single gang double gang or 4 10.16 cm square box The optional BG TR trim ring can be used if the BG 12LA is to be semi mounted activate the dual action pull station push in and pull down on the handle The word appears after the handle is pulled down This will remain until the pull sta is reset pull station includes one Double Pole Double Throw DPDT Normally Open N O which closes upon activation of the pull station the Pull Station Insert the key into the lock and rotate 1 4 turn counterclockwise Open the door until the handle returns to normal Close and lock the door Closing the door automatically resets the switch to the position Open the door will not activate or deactivate the alarm switch Do not loop wiring under any Break wire run to IDC supervision Do not detach the door of the pull station during installation The door of pull station cannot be reattached to the backplate after the backplate has already been onto an electrical box the Fire BG 12LA pull station in accordance with these instructions NFPA standards national and local Fire and Electrical codes and the requirements the AHJ Authority Having Jurisdiction Regular testing of the devices should be con in accordance with the appropriate NFPA standards Failure to follow these directions result in failure of the device to report an alarm condition Fire is not responsible for that have been improperly installed tested or maintained Compliance ADA compliance if the clear floor space only allows forward approach to an object the forward reach height allowed is 48 inches 121.92 cm If the clear floor space parallel approach by a person in a wheelchair the maximum side reach allowed is inches 137.16 cm