Fire-Lite BG-12LAO -12LAOB Manual Pull Station

File Preview
File Preview
Click below to download for free

File Data

Name fire-lite-bg-12lao-12laob-manual-pull-station-1839756024.pdf
Type PDF
Size 1.09 MB
Downloads

Text Preview

BG 12LAO 12LAOB Manual Pull Station U S Patent No Des 428,351 6,380,846 Other Patents Pending 51877 BG 12LAO 12LAOB pull station is a non coded dual action manual pull station with a key lock reset feature an approved outdoor gasket and an accompanying Outdoor Backbox It provides Fire control panels with one normally open N O initiating input A second set of contacts is rated up to 3 Amps at 30 V AC or DC for functions The BG 12LAO 12LAOB meets the ADAAG controls and operating guidelines section 4.1.3 13 and the ADA requirement for a 5 lb maximum force to activate the pull station Operating instructions are molded into the pull station along with Braille text Molded Terminal numbers are also present To meet UL requirements for outdoor use the BG 12LAO pull station must be to the SB I O backbox to create the BG 12LAOB model The BG 12LAO the WP 10 backbox is UL approved in retrofit applications Circuit Terminals 1 2 Rated to 25 Amp at 30 Volts AC or DC Contact Circuit Terminals 3 4 Rated to 3 Amps at 30 Volts AC or DC switch contacts N O are sealed and gold plated for reliability supplied Outdoor Backbox SB I O is surface mounted using the incorporated mount bosses The backbox can be positioned to allow conduit connection from any side and pull station will mount in any position activate the dual action pull station push in and pull down on the handle The word appears after the handle is pulled down This will remain until the pull sta is reset pull station includes one Double Pole Double Throw DPDT Normally Open N O which closes upon activation of the pull station the Pull Station Insert the key into the lock and rotate 1 4 turn counterclockwise Open the door until the handle returns to normal Close and lock the door Closing the door automatically resets the switch to the position Open the door will not activate or deactivate the alarm switch FACP To Next Device IDC Contact Contact Pull Station 51877 Gasket not cover any connections Do not loop wiring under any Break wire run to IDC supervision Do not detach the door of the pull station during installation The door of pull station cannot be reattached to the backplate after the backplate has already been onto an electrical box the Fire BG 12LAO 12LAOB pull station in accordance with these instructions NFPA standards national and local Fire and Electrical codes and the requirements the AHJ Authority Having Jurisdiction Regular testing of the devices should be con in accordance with the appropriate NFPA standards Failure to follow these directions result in failure of the device to report an alarm condition Fire is not responsible for that have been improperly installed tested or maintained Compliance ADA compliance if the clear floor space only allows forward approach to an object the forward reach height allowed is 48 inches 121.92 cm If the clear floor space parallel approach by a person in a wheelchair the maximum side reach allowed is inches 137.16 cm

Related Files