Fire-Lite BG-12LR and BG-12LRA Agent Release Pull Station
File Preview
Click below to download for free
Click below to download for free
File Data
Name | fire-lite-bg-12lr-and-bg-12lra-agent-release-pull-station-2631597840.pdf |
---|---|
Type | |
Size | 1.13 MB |
Downloads |
Text Preview
Wiring NEXT IDC Release Pull Station 51370 and BG 12LRA Agent Release Pull Station U S Patent No Des 428,351 6,380,846 Other Patents Pending 2 3 4 GAUGE 51370 BG 12LR and BG 12LRA Agent Release Pull Stations are designed for use with control panels that include releasing capabilities These stations are ideally suited areas such as clean rooms and computer rooms where a chemical agent is used to extin a fire Both pull stations provide a dual action normally open contact N O release point with a key lock reset feature The BG 12LRA also includes a manual abort System Normal LED and System Activated release LED Both stations meet the controls and operating mechanisms guidelines section 4.1.3 13 and the ADA for a 5 lb maximum pull force to activate the pull station Operating instructions molded into the pull station handle along with Braille text Molded terminal numbers also present contact N O is gold plated for reliability and rated at 0.25 A at 30 volts AC or BG 12LR pull station can be surface mounted to an SB 10 or SB I O surface backbox semi flush mounted on a standard single gang double gang or 4 10.16 cm square box The optional BG TR trim ring can be used if the BG 12LR is to be semi flush The BG 12LRA must be surface mounted to a SBA 10 backbox initiate an agent release push in and pull down on the handle The word after the handle is pulled down This will remain until the pull station is reset pull station includes one Single Pole Single Throw SPST Normally Open N O which closes upon activation of the pull station the Pull Station Insert the key into the lock and rotate 1 4 turn counterclockwise Open the door until the handle returns to normal Close and lock the door Closing the door automatically resets the switch to the position Open the door will not activate or deactivate the alarm switch DO NOT LOOP WIRING ANY TERMINALS BREAK WIRE TO MAINTAIN IDC SUPERVISION Do not loop wiring under any Break wire run to IDC supervision Do not detach the door of the pull station during installation The door of pull station cannot be reattached to the backplate after the backplate has already been onto an electrical box the Fire BG 12LR and BG 12LRA pull station in accordance with these instructions NFPA standards national and local Fire and Electrical codes and the requirements the AHJ Authority Having Jurisdiction Regular testing of the devices should be con in accordance with the appropriate NFPA standards Failure to follow these directions result in failure of the device to report an alarm condition Fire is not responsible for that have been improperly installed tested or maintained Compliance ADA compliance if the clear floor space only allows forward approach to an object the forward reach height allowed is 48 inches 121.92 cm If the clear floor space parallel approach by a person in a wheelchair the maximum side reach allowed is inches 137.16 cm agent release control panel release circuit or previous release initiating device To next agent release device or ELR last device on circuit 2 3 4 GAUGE Feature BG 12LRA only operation and reset of the BG 12LRA agent release pull station is the same as the BG 12LR the addition of the Abort Feature The System Normal LED will stay illuminated when the Release Control Panel is Systems Normal When the station has been activated ini the agent release process in the control panel the System Activated LED will illuminate the control panel has been configured to abort the releasing of an extinguishing agent pushing and holding in the abort switch will cancel the agent release sequence Please to the respective agent release control panel manual for further instructions about us the Abort feature Plate Wiring BG 12LRA only the wiring from the agent release control panel Abort Circuit to the wire leads of the normally open abort switch Connect 24 VDC to a form c relay this relay be called the Release Relay Connect the relay s normally closed contact to the System LED wire lead A Connect the relays normally open contact to the System Activated wire lead B Connect the 24 VDC to the LED assembly ground wire C VDC Relay Red Open Switch 2 3 4 Abort Switch End of line resistor on last unit used for CO2 releasing applications observe proper precautions as stated in NFPA Do not enter the protected space unless physical lockout and other safety procedures fully completed Do not use software disable functions in the panel as lockout For ADA if the clear floor space only allows forward approach to an object the maxi forward reach height allowed is 48 inches 121.92cm If the clear floor space allows approach by a person in a wheelchair the maximum side reach height allowed is inches 137.16cm