Fire-Lite BG-12LXSP Addressable Pull Station

File Preview
File Preview
Click below to download for free

File Data

Name fire-lite-bg-12lxsp-addressable-pull-station-9825164037.pdf
Type PDF
Size 1.26 MB
Downloads

Text Preview

BG 12LXSP Addressable Pull Station U S Patent No Des 428,351 6,380,846 Other Patents Pending 52148 BG 12LXSP Addressable pull station is a non coded dual action manual pull station a key lock reset feature It also has dual language Spanish English labeling and operat instructions It provides Fire intelligent control panels with one addressable alarm input The addressable module is housed inside the pull station The BG 12LXSP is with all Fire intelligent panels The BG 12LXSP meets the ADAAG controls operating mechanisms guidelines section 4.1.3 13 and the ADA requirement for a 5 maximum pull force to activate the pull station Operating instructions are molded into pull station handle along with Braille text Molded Terminal numbers are also present Operating Voltage 24 VDC Operating Current LED Flash 300 Range 32 F 120 F 0 C 49 C Humidity Range 10 93 non condensing BG 12LXSP Addressable pull station can be surface mounted to an SB 10 or SB I O backbox or semi flush mounted on a standard single gang double gang or 4 10.16 square electrical box The optional BG TR trim ring can be used if the BG 12LXSP is be semi flush mounted activate the dual action pull station push in and pull down on the handle The word appears after the handle is pulled down This will remain until the pull sta is reset pull station includes one Single Pole Single Throw SPST Normally Open N O which closes upon activation of the pull station the Pull Station Insert the key into the lock and rotate 1 4 turn counterclockwise Open the door until the handle returns to normal Close and lock the door Closing the door automatically resets the switch to the position Open the door will not activate or deactivate the alarm switch Pull Station 52148 2 3 4 GAUGE Do not detach the door of the pull station during installation The door of pull station cannot be reattached to the backplate after the backplate has already been onto an electrical box the Fire BG 12LXSP addressable pull station in accordance with these instructions NFPA standards national and local Fire and Electrical codes and the requirements the AHJ Authority Having Jurisdiction Regular testing of the devices should be con in accordance with the appropriate NFPA standards Failure to follow these directions result in failure of the device to report an alarm condition Fire is not responsible for that have been improperly installed tested or maintained Compliance ADA compliance if the clear floor space only allows forward approach to an object the forward reach height allowed is 48 inches 121.92 cm If the clear floor space parallel approach by a person in a wheelchair the maximum side reach allowed is inches 137.16 cm for Programming information the BG 12LXSP Address BG 12LXSP Addressable pull station is factory preset with address Set the address the pull station by turning the rotary address switches on the addressable module mounted the pull station Only one device per address is allowed Multiple modules may not set to the same address on the Signaling Line Circuit Once the address is set record it the space provided on the product ID label located inside the pull station ADDRESS SWITCHES OPERATION RED RED LED is visible translucent Opening the station door not activate or the alarm 3 2 1 O R M A L 50997 REV A IDENTIFICATION LABEL Approved Label Here in 12 Series ALARM BOX TO DOCUMENT

Related Files