Fire-Lite BG-12SL Manual Pull Station
File Preview
Click below to download for free
Click below to download for free
File Data
Name | fire-lite-bg-12sl-manual-pull-station-8639270145.pdf |
---|---|
Type | |
Size | 1.46 MB |
Downloads |
Text Preview
Wiring IN OUT IN OUT Pull Station 51860 Manual Pull Station U S Patent No Des 428,351 6,380,846 51860 BG 12SL pull station is a non coded single action manual pull station with pigtail con and a key lock reset feature It provides Fire control panels with one normally N O alarm initiating input The BG 12SL meets the ADAAG controls and operating guidelines section 4.1.3 13 and the ADA requirement for a 5 lb maximum force to activate the pull station Operating instructions are molded into the pull station along with Braille text contact N O is gold plated for reliability and rated at 0.25 A at 30 volts AC or BG 12SL pull station can be surface mounted to an SB 10 or SB I O surface backbox semi flush mounted on a standard single gang double gang or 4 10.16 cm square box The optional BG TR trim ring can be used if the BG 12SL is to be semi mounted activate the single action pull station simply pull down the handle The word appears after the handle is pulled down This will remain until the pull station is pull station includes one Single Pole Single Throw SPST Normally Open N O which closes upon activation of the pull station the Pull Station Insert the key into the lock and rotate 1 4 turn counterclockwise Open the door until the handle returns to normal Close and lock the door Closing the door automatically resets the switch to the position Open the door will not activate or deactivate the alarm switch Do not detach the door of the pull station during installation The door of pull station cannot be reattached to the backplate after the backplate has already been onto an electrical box the Fire BG 12SL pull station in accordance with these instructions NFPA standards national and local Fire and Electrical codes and the requirements the AHJ Authority Having Jurisdiction Regular testing of the devices should be con in accordance with the appropriate NFPA standards Failure to follow these directions result in failure of the device to report an alarm condition Fire is not responsible for that have been improperly installed tested or maintained Compliance ADA compliance if the clear floor space only allows forward approach to an object the forward reach height allowed is 48 inches 121.92 cm If the clear floor space parallel approach by a person in a wheelchair the maximum side reach allowed is inches 137.16 cm