Fire-Lite CDRM-300(A)
File Preview
Click below to download for free
Click below to download for free
File Data
Name | fire-lite-cdrm-300-a-2675913804.pdf |
---|---|
Type | |
Size | 730.63 KB |
Downloads |
Text Preview
Relay Monitor Module E 840 Devices CDRM 300 A multi output input module is designed for with Fire Fire Alarm Control Panels addressable module is intended for use in intelligent two loops It includes two individual relay control modules and Class B monitor modules Each relay output is intended for C switching applications which do not require wiring for the load circuit Each monitor input provides an between a fire alarm control panel and one or more open contact type devices Each relay output has its green LED Powered by SLC loop directly no external power required Mounts in standard junction boxes 4.0 10.16 cm square cm deep LEDs flash red during normal operation and latch on red to indicate alarm Compatible with LiteSpeed and CLIP systems Addressable analog communication Sleek low profile design Two wire SLC connection Rotary decimal addressing 01 159 with MS 9600UDLS MS 9600LS series systems and 01 99 with MS Firmware 4 Addresses can be viewed and changed without electronic Temperature 32 to 120 0 to 49 Humidity 10 93 non condensing 4.675 H x 4.275 W x 1.4 D Mounts to a 4 square by deep box Weight 6.3 oz 178.6 grams SPECIFICATIONS Operating Voltage 15 to 32 VDC Current Draw 24 mA 4 LEDs on Operating Current 1300 Contact Ratings A A A A A A A A VAC VDC VDC VDC VAC VDC VAC VAC APPLICATION 0.35 20ms 0.35 0.75 0.35 and Programming installation instructions shipped with the module and the Wiring Manual for complete details To ensure proper these modules shall be connected to listed compat system control panels only Mount on a standard junction box 4.0 10.16 cm square is at least 2.125 5.398 cm deep instructions are provided with each module Terminal screws are provided for and out wiring Surface mount box is available as an option Addressing Module base address Relay Output 1 Module base address 1 Monitor Input 1 Module base address 2 Relay Output 2 Module base address 3 Monitor Input 2 module can use up to four 4 addresses The base selected with the rotary address switches will be to relay output 1 from 00 to 156 The module will assign the next three addresses as appropriate monitored input 1 relay output 2 and monitored input 2 switch settings can disable relay output 2 or monitored 2 and free up those addresses NOTE This will affect see installation manual for details The inputs and outputs on CDRM 300 A provide Style B B circuits ONLY Style D Class A circuits are NOT sup in any application Listings and Approvals listings and approvals apply to the modules specified in document In some cases certain modules or applications not be listed by certain approval agencies or listing may in process Consult factory for latest listing status UL ULC Listed S2424 CSFM 7300 0075 0225 01 10 2012 Page 1 of 2 Line Information suffix indicates ULC Listed model Dual Relay Monitor Module Same as above but with ULC Listing Surface mount electrical box Alarms is a registered trademark of Honeywell International Inc by Honeywell International Inc All rights reserved Unauthorized use this document is strictly prohibited document is not intended to be used for installation purposes We try to keep our product information up to date and accurate cannot cover all specific applications or anticipate all requirements specifications are subject to change without notice more information contact Fire Alarms Phone 800 627 3473 FAX 877 699 4105 in the U S A 2 of 2 DF 60713 A 01 10 2012