Fire-Lite CHG-120F

File Preview
File Preview
Click below to download for free

File Data

Name fire-lite-chg-120f-5837604219.pdf
Type PDF
Size 763.43 KB
Downloads

Text Preview

CHG 120F Charger CHG 120F is a state of the art battery charging system for use with Fire fire alarm control panels It is designed to charge lead acid batteries between and 120 ampere hours AH Charges sealed lead acid batteries Automatic float type battery charger Rated for batteries of 25 to 120 ampere hours Obtains full float voltage within 48 hours For use on any 24 volt FACP which can handle the speci batteries and can disable the local charger AC Fail delay central station applications per latest NFPA Form C Trouble contact Dual outputs for easy load distribution Diagnostic LEDs Primary AC On Charger Trouble Ground Fault Hi Charge Lo Charge Battery Voltage Level 3 LEDs Low Battery Black or red BB 55F R battery cabinet Field selectable input voltage 120 VAC or 230 VAC Charges 26 AH batteries within 9 hours 55 60 AH batteries within 20 hours 120 AH batteries within 38 hours Values per Fire testing and Operation CHG 120F consists of a PC board and mounting chassis current is provided automatically when the battery falls below the charger output voltage the CHG 120F when batteries required for standby are between 25 to 120 AH Specifications AC TB1 115 VAC 60 Hz 2 A 230 VAC 50 Hz 1 A relay TB3 5 A at 30 VDC charge voltage 27.6 VDC charging current 4.5 A F1 F3 15 A sizes 26 AH to 120 AH D 225 Supplies Accessories time to charge two fully discharged batteries 25 AH 9 hours 55 AH 60 AH 20 hours 120 AH 38 hours CHG 120F mounts remotely in the BB 55F Battery Back Install the CHG 120F within 20 feet 6.096 m of the main in the left position of the BB 55F backbox Only one 55 AH battery or two 26 AH batteries will mount the charger board in the BB 55F Battery Box Battery Configurations The battery can mount configurations of batteries as follows Without CHG 120F mounted internally With CHG 120F mounted internally Up to two 26 AH batteries Up to two 55 AH batteries One 100 AH battery Up to two 26 AH batteries One 55 AH battery One 100 AH battery When 100 AH batteries are required a BB 55F is required mount each 100 AH battery Line Information Battery charger circuit board and mounting chas Includes mounting hardware and installation instructions 26 AH 12 volt sealed lead acid battery Order as pack BAT 12260 BP contains two 55 AH 12 volt sealed lead acid battery 10 18 2012 Page 1 of 2 100 AH 12 volt sealed lead acid battery Battery Backbox holds up to two BAT 12550 55 AH or one BAT 121000 100 AH battery Dimensions 24.0 61.0 cm wide x 14.0 35.6 cm high x 7.75 19.7 deep Door 24.125 61.3 cm wide x 14.25 36.2 cm x door adds 0.063 approx 0.16 cm to depth black Same as BB 55F above but painted red with Codes and Standards CHG 120F complies with the following standards NFPA 72 National Fire Alarm Code UL 864 Standard for Control Units for Fire Alarm Systems Features UL 1481 Power Supplies for Fire Alarm Systems CAN ULC S527 M87 Listings and Approvals listings and approvals below apply to the basic CHG In some cases certain modules may not be listed by approval agencies or listing may be in process Con factory for latest listing status UL S1287 ULC CS100 CSFM 7315 0075 0182 MEA 195 97 E Vol 2 Battery Backbox is a registered trademark of Honeywell International Inc by Honeywell International Inc All rights reserved Unauthorized use this document is strictly prohibited document is not intended to be used for installation purposes We try to keep our product information up to date and accurate cannot cover all specific applications or anticipate all requirements specifications are subject to change without notice more information contact Fire Alarms Phone 800 627 3473 FAX 877 699 4105 in the U S A 2 of 2 DF 51708 A1 10 18 2012

Related Files