Fire-Lite CMF-300(A)

File Preview
File Preview
Click below to download for free

File Data

Name fire-lite-cmf-300-a-5413068279.pdf
Type PDF
Size 755.19 KB
Downloads

Text Preview

CMF 300 A Module CMF 300 A Addressable Control Module provides intelligent control panels a circuit for Notification horns strobes etc Addressability allows the to be activated through panel programming on a zone or area of coverage basis is a communication protocol developed by Engineering that greatly enhances the speed of com between analog intelligent devices Intelligent communicate in a grouped fashion If one of the within the group has new information the panel CPU the group poll and concentrates on single points The effect is response speed greater than five times that of designs Built in type identification automatically identifies these to the control panel circuitry powered directly by two wire SLC loop CMF 300 A module requires power for horns etc LED green each time a communication is from the control panel and turns on steady red activated High noise immunity EMF RFI The CMF 300 A may be used to switch 24 volt NAC Wide viewing angle of LED SEMS screws with clamping plates for wiring ease Direct dial entry of address 01 159 for MS 9600 series 01 99 on MS 9200UDLS and MS 9050UD CMF 300 A is used to switch 24 VDC audible visual The face plate is made of off white heat resistant plastic Controls include two rotary switches for direct dial entry of setting The CMF 300 A is configured for a single Class B Style Y Class A Style Z Notification Appliance Circuit CMF 300 A uses one of the module addresses on a loop It responds to regular polls from the control panel reports its type and status including the open normal status of its Notification Appliance Circuit NAC The blinks with each poll received On command it activates internal relay The CMF 300 A supervises Class B Style or Class A Style Z notification or control circuits code command from the panel the CMF 300 A will dis the supervision and connect the external power sup in the proper polarity across the load device The of the supervision provides a positive indication the panel that the control relay actually turned ON The E 350 Devices power supply is always relay isolated from the com loop so that a trouble condition on the external supply will never interfere with the rest of the system switches set a unique address for each module The may be set before or after mounting The built in CODE not settable will identify the module to the con panel so as to differentiate between a module and a sen address operating voltage 15 to 32 VDC SLC current draw 6.5 mA LED on operating current 350 direct poll CLIP mode group poll LiteSpeed mode with LED flashing supply voltage maximum 80 volts RMS or DC on external supply 2 mA maximum using internal relay resistance 47K ohms range 32 to 120 0 to 49 range 10 to 93 non condensing 4.5 11.43 cm high x 4 10.16 cm wide x 3.175 cm deep Mounts to a 4 10.16 cm square x 5.398 cm deep box Listings and Approvals some cases certain modules may not be listed by certain agencies or listing may be in process Consult fac for latest listing status ULC S2424 Line Information Intelligent addressable control module 4 20 10 Page 1 of 2 Canadian intelligent addressable control Optional surface mount backbox Optional control module barrier required by UL for power limited and non power limited wiring in the junction box as CMF 300 A For installation instructions see document I56 1189 009 refer to the SLC Wiring Manual document 51309 The CRF relay module previously on this data sheet is now on DF is a trademark and Fire Alarms is a registered trademark Honeywell International Inc by Honeywell International Inc All rights reserved Unauthorized use this document is strictly prohibited document is not intended to be used for installation purposes We try to keep our product information up to date and accurate cannot cover all specific applications or anticipate all requirements specifications are subject to change without notice more information contact Fire Alarms Phone 800 627 3473 FAX 877 699 4105 in the U S A 2 of 2 df 52130 B2 4 20 10

Related Files