Fire-Lite CMF-300 Control Module Installation and Maintenance Instructions
File Preview
Click below to download for free
Click below to download for free
File Data
Name | fire-lite-cmf-300-control-module-installation-and-maintenance-instructions-9462073158.pdf |
---|---|
Type | |
Size | 1.27 MB |
Downloads |
Text Preview
InstallatIon anD maIntenance InstructIons FireLite Place CT 06472 203.484.7161 control module Operating Voltage Current Draw Operating Current NAC Line Loss Supply Voltage between Terminals T10 and T11 Maximum NAC NAC Current Ratings Range to 32VDC mA LED on LED flashing group poll mode 350 LED flashing direct poll mode 485 Max Communicating NAC Shorted VDC 24VDC class B wiring system the current rating is 3A For class A wiring system the current rating is 2A to 120 0 to 49 to 93 Non condensing H 4 W 11 4 D Mounts to a 4 square by 21 8 deep box Electrical Box CB500 Barrier 2a moDule mountIng BarrIer 2B InstallIng information is included as a quick reference installation guide Refer to control panel installation manual for detailed system information If the will be installed in an existing operational system inform the opera and local authority that the system will be temporarily out of service Dis power to the control panel before installing the modules This manual should be left with the owner user of this equipment DescrIptIon Supervised Control Modules are intended for use in addressable systems where the individual address of each module is selected the built in rotary switches This module is used to switch an external supply which can be a DC power supply to notification appliances It supervises the wiring to the connected loads and reports their status to panel as NORMAL OPEN or SHORT CIRCUIT The CMF 300 has two pairs output termination points available for fault tolerant wiring and a panel LED indicator This module can be used to replace a C304 module has been configured for supervised wiring operation requIrements ensure proper operation these modules shall be connected to listed com system control panels only 1a controls anD 1B Jumper locatIon CMF 300 mounts directly to 4 inch square electrical boxes see Figure The box must have a minimum depth of 21 8 inches Surface mounted boxes SMB500 are available The module can also mount to the or DNR W duct housing All wiring must conform to applicable local codes ordinances and When using control modules in nonpower limited applications CB500 Module Barrier must be used to meet UL requirements for the sepa of power limited and nonpower limited terminals and wiring The bar must be inserted into a 4 junction box and the control module be placed into the barrier and attached to the junction box Figure 2A power limited wiring must be placed into the isolated quadrant of the barrier Figure 2B Install module wiring in accordance with the job drawings and appropri wiring diagrams the address on the module per job drawings Secure module to electrical box supplied by installer as shown in 2A should be stripped to the appropriate length recommended strip length 1 4 to 3 8 Exposed conductor should be secured under the clamping plate should not protrude beyond the terminal block area Caution Do not loop under terminals Break wire run to provide supervision of connections When using the FCM 1 for fire fighter telephone applications Jumper J1 and discard The Jumper is located on the back as shown Figure 1B The module does not provide ring back when used as a firefigh circuit must be removed whenever power supply monitoring feature is not required 3 typIcal notIfIcatIon applIance cIrcuIt confIguratIon nfpa style y class B NOT LOOP WIRE ON TERMINALS 10 11 BREAK WIRE TO PROVIDE SUPERVISION OF CONNECTIONS VDC CIRCUIT MODULES TO COMPATIBLE CONTROL ONLY VDC POWER SUPPLY REGULATED LIMITED PER NFPA 70 FOR FIRE PROTECTION BATTERY BACKUP POLARITIES ARE IN ALARM LINE CIRCUIT SLC VDC MAX PAIR RECOMMENDED PANEL PREVIOUS NEXT EOL LISTED EOL SHOWN VDC COIL NEXT CONTROL MODULE OR RELAY ONE RELAY FOR EACH CIRCUIT SOME PANELS HAVE RELAY BUILT AND DO NOT REQUIRE EXTERNAL REFER TO PANEL MANUAL WIRING SHOWN IS SUPERVISED POWER LIMITED ANY FAULT IN THE POWER SUPPLY IS LIMITED TO THAT ZONE AND DOES NOT RESULT IN A FAULT IN A SEPARATE ZONE 4 typIcal fault tolerant notIfIcatIon applIance cIrcuIt confIguratIon nfpa style Z class a VDC CIRCUIT NOT LOOP WIRE ON TERMINALS 10 11 BREAK WIRE RUN TO PROVIDE OF CONNECTIONS MODULES TO LISTED CONTROL ONLY PANEL PREVIOUS POLARITIES ARE IN ALARM VDC POWER SUPPLY REGULATED LIMITED PER 70 LISTED FOR PROTECTION WITH BACKUP RESISTOR INTERNAL TERMINALS AND 9 LISTED EOL SHOWN VDC COIL NEXT CONTROL MODULE OR RELAY ONE RELAY FOR EACH CIRCUIT SOME PANELS HAVE RELAY BUILT AND DO NOT REQUIRE EXTERNAL REFER TO PANEL MANUAL WIRING SHOWN IS SUPERVISED POWER LIMITED ANY FAULT IN THE POWER SUPPLY IS LIMITED TO THAT ZONE AND DOES NOT RESULT IN A FAULT IN A SEPARATE ZONE relay switch contacts are shipped in the standby state open state but may have transferred to the activated closed state during shipping To ensure that switch contacts are in their correct state modules must be made to communicate with the panel before connecting circuits controlled by the module LINE CIRCUIT SLC VDC MAX PAIR RECOMMENDED NEXT FireLite Alarms Inc