Fire-Lite CO1224T CO1224A Conventional Carbon Monoxide Detector

File Preview
File Preview
Click below to download for free

Text Preview

CO1224T CO1224A Monoxide Detector monoxide CO is an odorless colorless tasteless and toxic gas that is produced when fuels such as wood charcoal and oil are burned with insufficient air The of residential and commercial fatalities caused from fuels come from heating systems power tools and char grills carbon monoxide is detected the CO1224T will alert by and flashing a temp 4 signal alarm Protection is 24 7 by a central station if connected to a panel a digital alarm communicator CO1224T is specifically designed for system operation means the detector is fully listed to UL Standard 2075 a code required trouble relay which sends a sensor or end of life signal to the control panel and the central as well as SEMS type terminal Phillips head screws provide a quicker and more positive wiring connection code required wiring supervision Also the offers low cur draw allowing more detectors to be connected to the without having to purchase a more expensive panel or extra power supply addressability to the by supervising the circuit with a monitor module such as the MMF 301 A to the CO1224T is RealTest technology that allows of its internal CO detector with a carbon monoxide gas There are few steps Hold the test button for two sec and after the green LED begins to flash about once per spray a small amount of CO into the detector The will alarm to indicate presence of gas RealTest technology allows installer to test detector with gas Full compliance with UL 2075 A code required trouble relay Wiring supervision with SEMS terminals A six year end of life timer 12 24 VDC A current draw of 20mA in standby and 40mA in alarm Versatile mounting for wall and ceiling Electrochemical sensing technology SPECIFICATIONS monoxide detector shall be a System Sensor model listed to UL 2075 for Gas and Vapor Detectors and The detector shall be equipped with a sounder and a relay The detector base shall be able to mount to a electrical box or direct surface mount to the wall ceiling Wiring connections shall be made by means of screws The detector shall provide dual color LED indi which blinks to indicate normal standby alarm or end When the sensor supervision is in a trouble condition detector shall send a trouble signal to the panel When the gives a trouble or end of life signal the detector shall replaced H 111 Initiating Devices SPECIFICATIONS Voltage 12 24 VDC Signal 85 dB in alarm Current 20 mA Current 40 mA 75 mA test Contact Ratings 0.5 A 30 VDC Contact Ratings 0.5 A 30 VDC SPECIFICATIONS 5.1 x 3.3 x 1.3 Weight 7 oz Temperature Range 0 to 40 32 to 104 Humidity Range 22 to 90 RH Terminals 14 to 22 AWG Single gang backbox surface mount to wall or ceil Modes LED LED 1 per 1 per in 4 in 4 Feature Pushing the Test Hush button will silence the for 5 minutes except in RealTest mode 10 26 2010 Page 1 of 2 Feature When the detector is in a trouble condition it send a trouble signal to the panel via the trouble contact Timer After the sensor inside the detector has the end of its useful life a trouble signal will be sent to panel This will indicate that it is time to replace the detect An electrochemical carbon monoxide detector life span is six years and the detector must be replaced by date marked on the inside of the product MODULE APPLICATIONS used in conjunction with the CO1224T the monitor should be programmed as a supervisory device type is not suitable for evacuation purposes Wire the module an NFPA Style B Class B Initiating Device Circuit and ter the with a 47K ohm End of line resistor provided and Approvals listings and approvals below apply to the CO1224T In cases certain modules may not be listed by certain agencies or listing may be in process Consult fac for latest listing status UL Listed E307195 Line Information 12 24 volt 4 wire system monitored carbon monox detector with RealTest Technology Replaces CO1224 CO detector replacement plate package of 5 previously installed round detectors footprints for a low profile finish is a trademark of Honeywell International Inc by Honeywell International Inc All rights reserved Unauthorized use this document is strictly prohibited document is not intended to be used for installation purposes We try to keep our product information up to date and accurate cannot cover all specific applications or anticipate all requirements specifications are subject to change without notice more information contact Fire Alarms Phone 800 627 3473 FAX 877 699 4105 in the U S A 2 of 2 DF 60463 B 10 26 2010

Related Files