Fire-Lite CP300 Smoke Detector

File Preview
File Preview
Click below to download for free

File Data

Name fire-lite-cp300-smoke-detector-1675083429.pdf
Type PDF
Size 682.24 KB
Downloads

Text Preview

February 7 1997 Ionization Detector Addressable Devices Fire MEA CP300 CP300 Addressable Ionization Detector is used ex with the Fire cid 149 Lite MS 9200 to sense products of and report the measured level of such prod to the control panel Since this detector is address it will help emergency personnel quickly locate a fire its early stages potentially saving precious rescue while also reducing property damage Unique unipolar dual chamber provides exceptional sta Factory preset at 1.5 nominal sensitivity for panel threshold level Fully coated circuit boards and superior RF transient Withstands air velocities up to 1,500 feet per minute triggering a false alarm Addressable by device Direct Decade 01 99 entry of address 2 Wire loop connection Visible LED cid 147 blinks cid 148 when the unit is addressed and on in alarm Integral communications and built in type identification Compact stylish design Built in functional test switch features push pin activa Low standby current Listed to UL 268 Built in tamper resistant feature Designed for direct surface mounting or electrical box Sealed against back pressure 94 V0 plastic flammability rating Removable cover and insect resistant screen for field Remote LED output connection Mounts to single gang box 3.5 or 4 octagonal box or square electrical box using a plaster ring Removable terminal block Easy wiring via removable 6 pin terminal block allows for to be removed from system without loss of power remaining loop ionization detectors in life safety applications to pro a broad range of fire sensing capability especially flaming fires Where smoldering fires are anticipated photoelectric sensor may provide faster response detectors are constructed of LEXAN in an off color The CP300 direct wire series of smoke detec are designed to commercial standards and offer an appearance is a registered trademark of GE Plastics a subsidiary of Electric Company document is not intended to be used for installation purposes We try to keep our information up to date and accurate We cannot cover all specific applications or all requirements All specifications are subject to change without notice For information contact Fire cid 149 Lite Phone 203 484 7161 FAX 203 484 7118 Clintonville Road Northford Connecticut 06472 and Manufacturing System Certified to Standard ISO 9001 in the U S A cid 151 Page 1 of 2 CP300 Plug In Detectors use a separate mounting to simplify installation service and maintenance base on box which is at least 1.5 inches 3.81 cm Suitable boxes include 4 10.16 cm square box with plaster ring 4 10.16 cm octagonal box 3.5 8.89 cm octagonal box Single gang box Because of the inherent supervision provided by the SLC end of line resistors are not required Wiring cid 147 T taps cid 148 or are permitted for Style 4 Class cid 147 B cid 148 wiring CP300 uses one of 99 possible addresses on the Signaling Line Circuit SLC It responds to regu polls from the system and reports its type and status CP300 Addressable Ionization Sensor cid 146 s unique unipo chamber responds quickly and uniformly to a broad of smoke conditions and can withstand wind gusts to 1,500 feet per minute without sending an alarm level Because of the unipolar chamber the CP300 is two times more responsive than most ion sensors This makes it a more stable detector range current current velocity humidity 10 93 non condensing LINE INFORMATION Same as above with ULC listing Remote LED Mounts to a single gang box 28 VDC peak cid 181 A 24 VDC mA 24 VDC latched cid 147 ON cid 148 ft min 7.6 m sec maximum inches 12.7 cm inches 7.6 cm 49 cid 176 C 32 cid 176 120 cid 176 F Ionization Sensor 2 of 2 cid 151 DF 51311

Related Files