Fire-Lite CRF-300-6

File Preview
File Preview
Click below to download for free

File Data

Name fire-lite-crf-300-6-9052183746.pdf
Type PDF
Size 929.66 KB
Downloads

Text Preview

CRF 300 6 A Relay Control Module CRF 300 6 six relay control module provides an fire alarm system with six Form C relays first module is addressed from 01 to 154 while the remain modules are automatically assigned to the next five higher Provisions are included for disabling a maximum of unused modules A single isolated set of dry relay con is provided for each module address which is capable of wired for either a normally open or normally closed The module allows the control panel to switch these on command No supervision is provided for the con circuit CRF 300 6 module has panel controlled green LED indi The panel can cause the LEDs to blink latch on or off Six addressable Form C relay contacts Removable 12 AWG 3.25 mm to 18 AWG 0.9 mm plug terminal blocks Status indicators for each point Unused addresses may be disabled Rotary address switches LiteSpeed or CLIP operation Mount one or two modules in a BB 2F cabinet optional Mount up to six modules on a CHS 6 chassis in a CAB 4 or BB 6F cabinet optional Mounting hardware included current 1.45 mA SLC current draw with all used if some addresses are disabled the standby decreases current 32 mA assumes all six relays have been once and all six LEDs solid ON range 32 to 120 0 to 49 10 to 93 non condensing 6.8 17.27 cm high x 5.8 14.73 cm wide x 2.54 cm deep weight 1.1 lb 0.5 kg including packaging options CHS 6 chassis BB 6F cabinet or BB 2F gauge 12 AWG 3.25 mm to 18 AWG 0.9 mm SLC wiring resistance 40 or 50 ohms panel current 30 mA relay pulse 15.6 ms pulse duration under panel control contact ratings 30 VDC 70.7 VAC E 930 Devices ratings 3.0 A 30 VDC maximum resistive non coded 2.0 A 30 VDC maximum resistive coded 1.0 A 30 VDC maximum inductive L R 2 ms coded 0.5 A 30 VDC maximum inductive L R 5 ms coded 0.9 A 110 VDC maximum resistive non coded 0.9 A 125 VAC maximum resistive non coded 0.7 A 70.7 VAC maximum inductive PF 0.35 non 0.3 A 125 VAC maximum inductive PF 0.35 non 1.5 A 25 VAC maximum inductive PF 0.35 non 2.0 A 25 VAC maximum inductive PF 0.35 non Listings and Approvals listings and approvals apply to the modules specified in document In some cases certain modules or applications not be listed by certain approval agencies or listing may in process Consult factory for latest listing status UL Listed S2424 ULC Listed S2424 CRF 300 6A MEA Listed 55 02 E CSFM 7300 0075 0205 Maryland State Fire Marshall Permit 2099 FM Approved Light Protective Signaling Only 4 12 2016 Page 1 of 2 Line Information Six relay control module Same as above with ULC Listing Optional cabinet for one or two modules Dimensions 9.234 23.454 cm wide 9.484 24.089 cm including x 12.218 31.0337 cm high x 0.672 1.7068 cm BACKBOX 9.0 22.860 cm wide 9.25 23.495 cm hinges x 12.0 30.480 cm high x 2.75 6.985 cm installed 7.150 18.161 cm wide overall x 7.312 cm high interior overall x 2.156 5.4762 cm deep Optional cabinet for up to six modules mounted on chassis below Dimensions DOOR 24.0 60.96 cm x 12.632 32.0852 cm high x 1.25 3.175 cm deep at bottom BACKBOX 24.0 60.96 cm wide x 12.550 cm high x 5.218 13.2537 cm deep Chassis mounts up to six modules in a BB 6F cabi is a trademark and FireLite Alarms is a registered trademark Honeywell International Inc by Honeywell International Inc All rights reserved Unauthorized use this document is strictly prohibited document is not intended to be used for installation purposes We try to keep our product information up to date and accurate cannot cover all specific applications or anticipate all requirements specifications are subject to change without notice more information contact Fire Alarms Phone 800 627 3473 FAX 877 699 4105 2 of 2 DF 52374 A 4 12 2016

Related Files