ECC 50 100 E Command Center ECC 50 100 and ECC 50 100E are multipurpose emer voice evacuation panels for fire applications mass notification or both The Primary Operating Consoles POCs 50 or 100 watts of audio power for distribution to up to eight circuits i e zones The ECC 50 100 E comes standard a single speaker circuit and a built in 25Vrms 50 watt amplifier secondary 50 watt amplifier ECC 50W 25 70V can be added for speaker circuit backup or to increase system capacity to two circuits and an additional 50 watts of audio power An ECC CE6 module added to the ECC 50 100 E will upgrade system to a maximum of eight speaker circuit outputs All output circuits can be wired in either Style Y Class B or Z Class A configuration The ECC 50 100 E has fourteen programmable messages up to 60 seconds each built in field pre and post announce tone generators and a fully Notification Appliance Circuit NAC with 2.0 amps of NAC power The ECC 50 100 E includes three built Form C relay contacts AC power trouble and MNS active a follower input for triggering the on board NAC circuit and special application power A built in power supply with switch technology delivers operational power to the panel and an battery charger supports charging up to 26AH batteries cabinet holds up to 18AH batteries fire protection applications the ECC 50 100 E is an adjunct to any UL listed FACP providing reverse polarity or contact can be used as a stand alone unit for non fire applications seamless integration between fire and mass notification the can be directly activated via serial communication the ES 200X MS 9600 UD LS or MS 9200UDLS Activa of the ECC 50 100 E via other FACPs uses the eight on board Input Circuits CMDs Two of the eight CMD circuits 1 CMD 2 can be individually field programmed for activa by an FACP Notification Appliance Circuit reverse polarity and eight can be activated by a contact closure In addition the ECC can be activated from a building Private Branch PBX with the integral night ring feature ECC 50 100 E programming is done by using a simple built in utility accessed from any laptop For added flexibility ECC 50 100 E supports both 25Vrms and 70.7Vrms speaker operation By adding a 70V transformer conversion module or an additional 70.7 volt secondary amplifier the system supports 70.7 volt speaker devices ECC 50 100 E can expand in order to accommodate larger or complex installations To add more control and increase sys capacity any combination of up to eight external remote con including the ECC LOC ECC RPU and ECC RM and up to distributed audio amplifiers including the ECC 50DA E ECC and ECC 125 DA E can be connected on the external data and audio riser data bus to create a fully integrated command A fully loaded system supports up to 1100 watts of total audio and up to 24 speaker circuit outputs APPLICATIONS Schools Theaters Auditoriums Dormitories Healthcare Facilities Military facilities Places of Worship Factories Office Buildings Restaurants C 200 Communications UL Listed to UL 2572 Communication Control Units Mass Notifi Systems and UL 864 emergency voice evacuation for Modular design for system flexibility and easy expansion Removable terminal blocks for ease of servicing and module 50 watts of 25V audio power expandable to 100 watts RMS 2 amp Notification Appliance Circuit NAC output sync genera or follower for System Sensor Wheelock or Gentex protocols Optional 70.7VRMS conversion transformer available for the pri amplifier Note that speaker wiring continues to be super in standby alarm and when background music is playing this optional transformer installed Eight Command Input Circuits to activate messages 1 to 8 CMD1 and CMD2 are field selectable to be activated from 12 or VDC Notification Appliance Circuits reverse polarity or con closures CMD3 CMD8 are activated by contact closures Speaker Circuits Single Style Y Class B or Style Z Class A speaker Circuit Two Style Y Class B or Style Z Class A speaker circuits with ECC 50W 25 70V Audio Amplifier installed Eight Style Y Class B or Style Z Class A speaker circuits optional ECC 50W 25 70V and ECC CE6 installed 520Hz square wave tones available which can be uploaded to ECC 50 100 to meet NFPA Low Frequency requirements to the Device Compatibility Document 15384 for listed speakers ECC 50 100 E can be controlled by an FACP via the ANN ACS link Compatible FACPs include the ES 200X MS and MS 9200UDLS 8 15 2018 Page 1 of 6 Certified for seismic applications when used with the appropriate mounting kit supervised microphone Microphone time out feature which reverts back to prerecorded if emergency page exceeds the programmed time 14 recorded messages Field selectable message and custom message recording capa using the local microphone a USB port or an external audio External Audio Input can be used for background music Up to 60 second message duration for all messages tone generators field selectable for multiple tone types Powered by integral AC power supply or batteries during AC fail Programmable delay of immediate 2 hours or 6 hours reporting AC Loss Piezo sounder for local trouble 100 event history log Three Form C relays AC Power Loss Relay TB1 System Trouble Relay TB2 MNS Active TB3 DF 60762 500mA 0.5A Special Application auxiliary power output for modules when interfaced with compatible address FACPs and End of Line power supervision relays System Status LEDs Refer to and Indicators in prod manual LS10001 000FL E Dress Panel Optional TR CE semi flush trim ring Any combination of up to eight 8 external remote consoles Optional ECC RM Remote Microphone includes cabinet See Optional ECC RPU Remote Page Unit includes cabinet See Optional ECC LOC Local operator console includes cabinet Any combination of up to eight 8 distributed audio amplifiers Optional ECC 50DA E distributed amplifier 50 watts See DF Optional ECC 125DA E distributed amplifier 125 watts See Optional ECC 50BDA distributed amplifier with backup 100 DF 60760 Internal Expansion Modules Circuit Expander Module provides connections for up to Style Z Class A or Style Y Class B speaker circuits Circuits configured through the web based programming utility 25V 50 watt audio amplifier module Adding a sec speaker circuit increases the total ECC 50 100 power output to watts or can also be used as a backup amplifier 70V 50 watt audio amplifier module Adding a sec speaker circuit increases the total ECC 50 100 power output to watts or can also be used as a backup amplifier 70V Transformer Conversion Module Converts the primary amplifier to a 70V output This transformer directly to the ECC 50 100 E main control board by two brackets 2 of 6 DF 60734 B1 8 15 2018 and Indicators BUTTON CONTROLS All Call MNS Control System Control Speaker Select 1 24 Message Select 1 14 Diagnostic Select Trouble Silence Console Lamp Test Status Indicators visible with door Fire System Active green MNS Control green System Control green System in Use green Speaker Zone 1 24 Active green Speaker Zone 1 24 Fault yellow OK to Page green Microphone Trouble yellow Message 1 8 Active red Message 1 8 Fault yellow Remote Amplifier 1 8 Fault yellow LOC RPU RM 1 8 Fault yellow LOC RPU RM 1 8 Active green Main Console Fault yellow AC P

Related Files