Fire-Lite ECC-50DA(E), ECC-50BDA, ECC-125DA(E)

File Preview
File Preview
Click below to download for free

File Data

Name fire-lite-ecc-50da-e-ecc-50bda-ecc-125da-e-3580741296.pdf
Type PDF
Size 864.57 KB
Downloads

Text Preview

ECC 50DA E Audio Amplifiers ECC 50DA E ECC 50BDA and ECC 125DA E are 50 watt 100 watt and 125 watt amplifiers that are with the ECC 50 100 E Emergency Command Center distributed audio amplifiers amplify an audio message distribution throughout a facility when additional audio is required They are designed as self contained units can be conveniently installed near an area of protection to wiring demands for speaker circuit outputs ECC 50DA E is capable of producing 50 watts of total and includes four built in fully supervised speaker cir The ECC125DA E is capable of producing 125 of total power with four built in fully supervised speaker Both amplifiers are expandable to include eight circuits when an optional ECC CE4 module is installations that require survivability the ECC 50BDA pro 50 watts or 100 watts of primary power along with 50 of backup power and comes standard with eight built in supervised speaker circuits zones combination of up to eight ECC 50DA E s ECC or ECC 125DA E s can be connected to the ECC to provide a total output of 1100 watts of audio and up to 24 speaker circuit outputs These distributed amplifiers are wired to the data bus and the Audio Riser of the ECC 50 100 E primary operating console They their own power supplies with built in battery charger and both fully supervised by the ECC 50 100 E for any trouble The ECC 50DA E and ECC 125DA E units come stan with four onboard fully supervised speaker circuit and are expandable to eight circuits when an ECC CE4 module is added The ECC 50BDA includes eight onboard fully supervised circuits zones Any combination of up to eight ECC 50DA E s ECC or ECC 125DA E s per system can be used with ECC 50 100 E for a total of 1100 watts of audio power 24 speaker circuit outputs The ECC 50BDA can be used in the following configura 50 Watts primary 50 Watts back up 100 watts primary No back up 100 watts primary 50 Watts backup Optional ECC required The ECC 50BDA supports the use of low frequency sound per UL 464 Refer to the Device Compatibility Docu 15384 for compatible devices Supports both Class A Style Z and Class B Style Y wir Easy setup and configuration by using a simple built in based programming utility on the ECC 50 100 E UL2572 Communication and Control Units Mass Notifica Systems UL 864 Emergency Voice Evacuation for C 210 Communications Built in power supply and battery charger that supports up 35AH For batteries larger than 18 AH use the BB 26 or Battery Box ECC 50DA E and ECC 50BDA are field selectable for or 70.7Vrms of operation Sturdy scratch resistant cabinet SUITABLE APPLICATIONS Schools Theaters Auditoriums Dormitories Healthcare Facilities Factories Military Facilities Places of Worship Restaurants Office Buildings ECC 50DA E ECC 50BDA and ECC 125DA E can be or flush mounted ECC 50DA E ECC 50BDA and ECC 125DA E are only with the ECC 50 100 E Emergency Command Specifications AC POWER ECC 50DA 120VAC 60Hz 1200mA max ECC 50DAE 240VAC 50Hz 600mA max ECC 50BDA 120VAC 60Hz 2470mA max ECC 125DA 120VAC 60Hz 2200mA max ECC 125DAE 240VAC 50Hz 1250mA max 6 30 2015 Page 1 of 4 70V Transformer conversion module for 70V Local Operator Console Complete user interface refer to the data sheet DF 60762 for more information Remote Page Unit Hand held microphone 14 buttons Please refer to the data sheet DF 60761 for information Remote Microphone only Please refer to the data DF 60760 for more information Fire Fighter Telephone System Please refer to the sheet DF 60765 for more information Remote Phone Jack Fire Fighters Remote Handset Fire Fighters Handset Cabinet Recessed Fire Fighters Handset Cabinet Surface Mount Addressable Mini Monitor Module SLC Line Isolation Module Optional Trim Ring 25 to 75 ampere hours AH external battery charger 25 120 ampere hours AH external battery charger Replacement microphone only Optional Thumb Latch Non UL Listed Battery 12volt 7.0AH Two required Battery 12volt 12.0AH Two required Battery 12volt 18.0AH Two required Battery 12volt 26.0AH Two required Modules Circuit Expander Module provides connections for to four Style Z Class A or four Style Y Class B speaker Circuits are configured through the web based pro utility on the ECC 50 100 E Expander card for ECC 50BDA remote amplifier 100 watt primary 50 watt back up operation Requirements Product manual part number LS10027 000FL E for wiring requirements Specifications W x 26.25 H x 4.125 D 40.64cm W x 66.68cm H x D Specifications Weight 25.8 lbs 11.7kg Weight 25.8 lbs 11.7kg Weight 24.3 lbs 11.02kg Weight 24.3 lbs 11.02kg Weight 28 lbs 12 kg Weight 3 lbs 1 kg POWER ECC 50DA E 50 watts primary only or ECC 50BDA 50 watts primary 50 watts back up 25Vrms 70.7Vrms 100 watts primary only or 100 watts primary 50 watts back up 25Vrms 70.7Vrms ECC 50WBU installed ECC 125DA E 125 watts primary only 25Vrms OUTPUTS ECC 50DA E Four 4 supervised Class B Style Y or A Style Z outputs Expandable to eight with ECC ECC 50BDA 8 supervised Class B Style Y or Class A Z outputs ECC 125DA E Four 4 supervised Class B Style Y or A Style Z outputs Expandable to eight with ECC POWER BATTERY CHARGING CIR Supports lead acid batteries only Battery charge capability 7AH to 35AH ECC 50DA E ECC 50BDA and the ECC 125DA E only support up to 18AH For batteries larger than use the BB 26 or the BB 55F battery box A minimum 35AH is allowed per system Accessories Battery cabinet used to mount up to two 26AH Batter BAT 12260 Battery cabinet used to mount up to two 55AH Batter BAT 12250 Line Information Ordering Distributed Remote Audio Amplifier 50 watts Distributed Remote Audio Amplifier with back up watts 100 watts at 25Vrms or 70Vrms Distributed Remote Audio Amplifier Export version Distributed Remote Audio 50 watts 240 VAC 50 Hz Export version Distributed Remote Audio 125 watts 240 VAC 50 Hz Primary operating Console 50 Watt 25VRMS speaker zone emergency voice evacuation system microphone built in tone generator and 14 recordable Please refer to the data sheet DF 60734 for more Export version Primary operating Console 50 25VRMS single speaker zone emergency voice evacua system Integral microphone built in tone generator and recordable messages 240 VAC 50 Hz Please refer to the sheet DF 60734 for more information Speaker Circuit Zone Expander Module 25V 50 watt audio amplifier module Adding a speaker circuit increases the total ECC 50 100 power to 100 watts or can also be used as a backup amplifier 70V 50 watt audio amplifier module Adding a speaker circuit increases the total ECC 50 100 power to 100 watts or can also be used as a backup amplifier 2 of 4 DF 60763 C 6 30 2015 amplifier circuit options Circuit Circuits TB21 firefighter telephone local console remote unit remote battery J7 audio 50W amplifier 125W amplifier 50 100W amplifier CHG 120F charger charger Emergency Command Center Possible Configuration

Related Files