Fire-Lite ECC-RM Remote Microphone

File Preview
File Preview
Click below to download for free

File Data

Name fire-lite-ecc-rm-remote-microphone-5180739426.pdf
Type PDF
Size 839.59 KB
Downloads

Text Preview

ECC RM Microphone ECC RM is an optional Remote Microphone that is with the ECC 50 100 E Emergency Command for fire protection applications It is part of a family of remote consoles that allows for extending the opera interface to remote locations within a building It is housed a cabinet with a keyed or an optional thumb lock to limit to qualified personnel ECC RM remote microphone allows for ALL CALL paging be broadcast over the speaker circuits when depressing the push to talk switch The RM requires an external bus connection an external audio riser connection and external operator interface power connection 24 Volts DC the ECC 50 100 main console APPLICATIONS Schools Theaters Auditoriums Dormitories Healthcare Facilities Military facilities Places of Worship Factories Restaurants Office Buildings External remote console that provides ALL CALL paging over the speaker zones of the ECC 50 100 E operating console Modular design for maximum system flexibility and easy Supports both Class A Style Z and Class B Style Y wir A maximum of eight ECC RMs can be connected to an primary operating console Built in microphone with push to talk feature that can be for ALL CALL paging Sturdy cabinet design with a keyed lock to prevent unautho access Optional thumb lock is available Simple and straightforward user interface Specifications POWER REQUIREMENTS 24VDC non resettable power from the ECC 50 External Operator Interface Power Non supervised ECC 50 100 E Product Manual P N LS10001 000FL E standby and alarm current requirements as well as battery Requirements Product Installation Document PN LS10029 000FL E detailed wiring requirements Listings and Approvals listings and approvals below apply to the ECC RM Microphone In some cases certain modules may not C 240 Communications listed by certain approval agencies or listing may be in pro Consult factory for latest listing status Listed S2424 6912 0075 0228 COA 6152 Approved and Codes ECC RM complies with NFPA 101 Life Safety Code and the following UL Standards and with NFPA 72 Fire Alarm requirements 864 and Humidity ranges system meets NFPA requirements for operation at 0 49 F and at a relative humidity 93 2 RH non at 32 2 90 3 However the useful of the system s standby batteries and the electronic com may be adversely affected by extreme temperature and humidity Therefore it is recommended that this and its peripherals be installed in an environment with normal room temperature of 15 27 C 60 80 F Specifications 21.082 cm high x 6.080 15.44 cm wide x 4.337 11.02 deep Door attached and closed Specifications 4 lbs 1.81 kg 6 23 2015 Page 1 of 4 Amplifier options Circuit Expander Circuit Circuits TB21 Firefighter Telephone Operator Console Paging Unit Microphone battery J7 audio remote amplifier remote amplifier remote amplifier CHG 120F charger charger Emergency Command Center Possible Configurations 2 of 4 DF 60760 C 6 23 2015 VISIBLE WITH DOOR and Indicators BUTTON CONTROLS Microphone Push to talk switch STATUS System in Use green OK to Page green AC Power green Data Trouble yellow Audio Trouble Yellow Microphone Trouble yellow Line Information Ordering Remote Microphone only Primary operating Console 50 Watt 25VRMS speaker zone emergency voice evacuation system microphone built in tone generator and 14 recordable Please refer to the data sheet DF 60734 for more Export version Primary operating Console 50 25VRMS single speaker zone emergency voice evacua system Integral microphone built in tone generator and recordable messages Please refer to the data sheet DF for more information Speaker Circuit Zone Expander Module 25V 50 watt audio amplifier module Adding a speaker circuit increases the total ECC 50 100 power to 100 watts or can also be used as a backup amplifier 70V 50 watt audio amplifier module Adding a speaker circuit increases the total ECC 50 100 power to 100 watts or can also be used as a backup amplifier 70V Transformer conversion module for 70V Local Operator Console Complete user interface refer to the data sheet DF 60762 for more information Remote Page Unit Hand held microphone 14 buttons Please refer to the data sheet DF 60761 for information Distributed Remote Audio Amplifier 50 watts refer to the data sheet DF 60763 for more information Distributed Remote Audio Amplifier with 50 watts 100 watts at 25Vrms or 70Vrms Please refer the data sheet DF 60763 for more information Expander card for ECC BDA remote amplifier 100 watt primary 50 watt backup operation Please refer to data sheet DF 60763 for more information Distributed Remote Audio Amplifier 125 watts refer to the data sheet DF 60763 for more information Export version Distributed Remote Audio 50 watts 240 VAC 50 Hz Please refer to the data DF 60763 for more information Export version Distributed Remote Audio 125 watts 240 VAC 50 Hz Please refer to the data DF 60763 for more information Distributed Audio Speaker Circuit Zone expander Fire Fighter Telephone System Please refer to the sheet DF 60765 for more information Remote Phone Jack Fire Fighters Remote Handset Fire Fighters Handset Cabinet Recessed Fire Fighters Handset Cabinet Surface Mount Addressable Mini Monitor Module SLC Line Isolation Module Optional Trim Ring Replacement Microphone Only 25 to 75 ampere hours AH external battery charger 25 120 ampere hours AH external battery charger Battery 12volt 7.0AH Two required Battery 12volt 12.0AH Two required Battery 12volt 18.0AH Two required Battery back box Mounts up to 2 BAT 12260 Battery Box Mounts up to 2 BAT 12260 or BAT Monitor module used to supervise dry contact input Optional Thumb Latch Non UL Listed 6 23 2015 Page 3 of 4 Alarms is a registered trademark of Honeywell International Inc by Honeywell International Inc All rights reserved Unauthorized use this document is strictly prohibited document is not intended to be used for installation purposes We try to keep our product information up to date and accurate cannot cover all specific applications or anticipate all requirements specifications are subject to change without notice more information contact Fire Alarms Phone 800 627 3473 FAX 877 699 4105 in the USA 4 of 4 DF 60760 C 6 23 2015

Related Files