Fire-Lite FCPS-24FS8

File Preview
File Preview
Click below to download for free

File Data

Name fire-lite-fcps-24fs8-4136970825.pdf
Type PDF
Size 791.35 KB
Downloads

Text Preview

FCPS 24FS8 24 Volt Power Supply Fire FCPS 24FS8 C E is a compact cost effec 8 amp remote power supplies with battery charger The may be connected to any 12 or 24 volt fire control panel FACP or may stand alone Primary appli include notification appliance bell circuit NAC to support ADA requirements and NAC synchroni or auxiliary power to support 24 volt system accesso The FCPS provides regulated and filtered 24 VDC power four notification appliance circuits configured as either two B Style Y and Class A Style Z with ZNAC 4 option or four class B only Alternately the four outputs may configured as any combination of resettable non resettable outputs optimal for powering four wire smoke detec The FFCPS 24FS8 C E also contains a battery charger of charging up to 18.0 Amp hour batteries FCPS is ULC listed Unless otherwise specified the term FCPS 24FS8 used in document refers to the standard FCPS 24FS8 FCPS FCPS 24FS8E UL Listed Notification Appliance Circuit NAC synchroniza using System Sensor Wheelock or Gentex appliances Operates as a or as a See note on page 2 Contains two fully isolated input control circuits triggered FACP NAC NAC expander mode or jumped perma stand alone mode Two Class B Style Y or Class A Style Z with ZNAC 4 NACs circuits 1 3 8 amp full load output with 3 amps maximum circuit in expander mode UL 864 6 amp continuous output in stand alone mode UL 1481 Compatible with coded inputs signals passed through Optional power supervision relay EOLR 1 stand alone mode output power circuits may be config as resettable reset line from FACP required or a mix of two and two Fully regulated and filtered power output optimal for pow four wire smoke detectors annunciators and other peripherals requiring regulated filtered power Power limiting technology meets UL power limiting require Form C normally closed trouble relay Fully supervised power supply battery and NACs Selectable earth fault detection AC trouble report selectable for immediate 2 hour delay Works with virtually any UL 864 fire alarm control which uti an industry standard reverse polarity notification cir including unfiltered and unregulated bell power Requires input trigger voltage of 9 32 VDC Self contained in compact locking cabinet 15 x 14.5 2.75 cm 38.1H x 36.83W x 6.985D D 050 Supplies Accessories integral battery charger capable of charging up to AH batteries Cabinet capable of housing 7.0 AH batter Battery charger may be disabled via DIP switch for applica requiring larger batteries Fixed clamp type terminal blocks accommodate up to 12 3.1mm2 wire AC Power FCPS 24FS8 120 VAC 60 Hz 3.2A maximum FCPS 24FS8 E 240 VAC 50 Hz 1.6A maximum Wire Size minimum 14 AWG 2.0mm2 with 600 V insula 16 V Input Circuit Trigger Input Voltage 9 to 32 VDC Trigger Current 2.0 mA 16 32 V Per Input 1.0 mA 9 Contact Rating 5 A at 24 VDC Power Output Specific application power 500 mA Circuits 24 VDC filtered regulated 3.0 A maximum for any one circuit Total continuous current for all outputs stand alone mode FCPS 24FS8 6.0 A maximum Total short term current for all outputs NAC expander mode FCPS 24FS8 8.0 A maximum 5 17 13 Page 1 of 4 Listings and Approvals listings and approvals apply to the modules specified in document In some cases certain modules or applications not be listed by certain approval agencies or listing may in process Consult factory for latest listing status UL Listed S2424 ULC Listed S2424 CSFM Approved 7315 0075 206 MEA 219 02E Information 6.0 A 120 VAC remote charger power supply main printed circuit board transformers enclosure x 14.5 x 2.75 cm 38.1H x 36.83W x 6.985D and instructions is ULC listed 6.0 A 240 VAC remote charger power supply main printed circuit board transformers enclosure x 14.5 x 2.75 cm 38.1H x 36.83W x 6.985D and instructions Class A Style Y NAC option module 12 24 VDC end of line relay for monitoring four wire detector power Battery 12 volt 7.0 AH two required Battery 12 volt 7.0 AH two required Optional module mounting kit is required to install an module on the power supply main circuit board Power Battery Charging Circuit Supports lead acid batteries only Float charge voltage 27.6 VDC Maximum current charge 250 mA Maximum battery capacity 7.0 AH 1 Expand notification appliance power an additional A Use up to four Class B Style Y outputs or four Class A Z outputs using ZNAC 4 For example the FACP noti appliance circuits will activate the FCPS when reverse activation occurs Trouble conditions on the FCPS are by the FACP through the notification appliance circuit 2 Use the FCPS to expand auxiliary regulated 24 system power up to 6.0 A Both resettable and non reset power options are available Resettable outputs are cre by connecting the resettable output from the FACP to one both of the FCPS inputs 3 Use addressable control modules to activate the instead of activating it through the FACP notification circuits This typically allows for mounting the FCPS greater distances away from the FACP while expanding architecture in various applications example an addressable control module is used to acti the FCPS and an addressable monitor module is used to FCPS trouble conditions Local auxiliary power output the FCPS provides power to the addressable control Addressable FACPs are capable of locating control and modules at distances of up to 10,000 feet 3,046 meters Follower Generator Note some installations it is necessary to synchronize the flash of all strobes in the system for ADA compliance accomplish this by monitoring very short timing pulses the NAC power which are created by the FACP When at the end of a NAC wire run the FCPS 24FS8 can i e the strobe synchronization timing pulses on existing NAC wire run This maintains the overall system timing of the additional strobes attaches to the FCPS the FCPS 24FS8 is configured via DIP switch settings a follower the FCPS NAC outputs track the strobe pulses present at the FCPS sync input ter The pulses originate from an upstream FACP or other supply the FCPS 24FS8 is configured via DIP switch settings a generator the FCPS sync input terminals are not Rather the FCPS is the originator of the strobe synchro pulses on the FCPS NAC outputs In genera mode the sync type System Sensor Wheelock or is selectable via DIP switch settings and Codes FCPS 24FS8 complies with the following standards NFPA 72 National Fire Alarm Code UL 864 Standard for Control Units for Fire Alarm Systems expander mode UL 1481 Power Supplies for Fire Alarm Systems 2 of 4 DF 52310 A2 5 17 13 Block Diagram 5 17 13 Page 3 of 4 Layout Sensor and FireLite Alarms are registered trademarks of International Inc by Honeywell International Inc All rights reserved Unauthorized use this document is strictly prohibited document is not intended to be used for installation purposes We try to keep our product information up to date and accurate cannot cover all specific applications or anticipate all requirements specifications are subject to change without notice more information conta

Related Files