Fire-Lite Gentex AVP Strobe
File Preview
Click below to download for free
Click below to download for free
File Data
Name | fire-lite-gentex-avp-strobe-3584976120.pdf |
---|---|
Type | |
Size | 779.34 KB |
Downloads |
Text Preview
July 28 1998 AVP Retrofit Strobes Audio Visual Devices Gentex AVP Series is designed to make ADA retrofits snap allowing the combination of existing audible appli with ADA compliant strobes FEATURES 24 VDC xenon visible appliances UL 1971 listed Flash rate of 1 Hz 15 75 and 30 75 models provide 75 candela minimum Accepts most audible appliances front mount horn bell output or speakers Tamper resistant lens Polarized in out wiring Complies with ADA 4.28.3 mounting requirements of 80 m from floor Available in Fire Alarm Red Strobes available in wall mount configurations only Textured finish Flying leads INFORMATION 1 cid 147 WR cid 148 Wall mount Red faceplate 2 ALL 24 VDC MODELS operate from 21 30 VDC 20 10 At 24 VDC 15 75 candela units have a startup current of 130 mA and a peak operating current of 110 mA 30 75 units have a startup current of 120 mA and a peak operating current of 160 mA 110 candela units have a current of 148 mA and a peak operating current of 240 mA document is not intended to be used for installation purposes We try to keep our information up to date and accurate We cannot cover all specific applications or all requirements All specifications are subject to change without notice For information contact Fire cid 149 Lite Phone 203 484 7161 FAX 203 484 7118 Clintonville Road Northford Connecticut 06472 and Manufacturing System Certified to Standard ISO 9001 in the U S A cid 151 Page 1 of 2 All strobes are designed to flash as specified with continuous applied voltage appliance is NOT recommended for use on coded or pulsing signaling cir CONDUCTIVITY 18 AWG 0.75 mm2 cid 151 60 AWG 1.30 mm2 cid 151 95 AWG 2.00 mm2 cid 151 153 AWG 3.25 mm2 cid 151 244 Power is supplied when control panel is latched WIRE DISTANCE in feet Panel Voltage cid 151 Device Minimum Voltage Wire Conductivity wire distance includes wire to and from device Current Draw Equation above applies only to regulated devices Each wire run must be broken to provide supervision signal circuit mounting boxes 4 10.16 cm square metal or non metallic switch outlet 1 1 2 3.81 cm deep minimum Gangable 2 gang switch masonry outlet boxes 1 1 2 cm deep minimum guidelines Mount one box for each signaling device Run insulated conductor from the signaling circuit in the Use UL listed Class 1 wire 2 of 2 cid 151 DF 51924