Fire-Lite H355(A) Series Intelligent Addressable Thermal Detectors

File Preview
File Preview
Click below to download for free

Text Preview

Series Addressable Detectors E 710 Devices Fire Alarms H355 A Series thermal detectors are sensors that use a state of the art thermistor circuit for fast response These sensors provide open protection and are intended for use with Fire Fire Alarm Control Panels FACPs H355 A and H355R A sensors provide fixed tempera alarm detection at 135 57 The H355R A sensor responds to rate of rise conditions of greater than 15 per minute The H355HT A is a fixed high tempera detector that activates at 190 88 These thermal provide addressable property protection in a variety applications LEDs on each sensor light to provide a local visible sen indication Remote LED annunciator capability is available an optional accessory the RA100Z loop Two wire SLC loop connection Unit uses base for wiring Addressable by device Rotary decimal addressing 01 159 with MS 9600 series 99 with MS 9200 series Sleek low profile stylish design State of the art thermistor technology for fast response communications and built in device type identifica Built in tamper resistant feature Built in functional test switch activated by external magnet Factory preset at 135 57 for the H355 A and 190 88 for the H355HT A Rate of rise triggers at 15 8.3 per minute for the 360 viewing angle of the visual alarm indicators two LEDs LEDs blink red in Normal condition and turn steady red in Alarm Visible LEDs every time the unit is addressed Sealed against back pressure SEMS screws for wiring of the separate base Designed for direct surface or electrical box mounting Plugs into separate base for ease of installation and main Separate base allows interchange of photoelectric ioniza and thermal sensors system features Remote test feature from the panel Walk test with address display Low standby current in B210LP A Base 94 5V plastic flammability rating Remote LED output connection to optional RA100Z remote annunciator Flanged surface mounting kit Series plug in intelligent thermal detectors use a base to simplify installation service and mainte Installation instructions are shipped with each detector base all base types on an electrical backbox which is least 1.5 3.81 cm deep For a chart of compatible junction see DF 60059 Because of the inherent supervision provided by the SLC end of line resistors are not required Wiring or are permitted for Style 4 Class wiring only thermal detectors for protection of property detectors are constructed of off white fire resistant The H355 A Series plug in intelligent thermal detec are designed to commercial standards and offer an attrac appearance H355 A Series detector uses one of 159 MS 9600 or 99 MS 9200 series possible addresses on a con panel SLC loop It responds to regular polls from the con panel and reports its type and the status If it receives a command from the panel or a local magnet test it stimu its electronics and reports an alarm It blinks its LEDs polled and turns the LEDs on when commanded by the The H355 A Series offers features and performance represent the latest in thermal detector technology 5 17 2013 Page 1 of 2 BASES suffix indicates ULC Listed model The detector plug in base can be changed off for special For details about intelligent bases and their mount see DF 60059 Plug in detector base included standard U S low profile mounting base Bulk pack of B210LP package contains 10 Standard European flangeless mounting base Bulk pack of B501 package contains 10 Intelligent sounder base capable of producing output with ANSI Temporal 3 or continuous tone B501BH series bases in retrofit applications Plug in System Sensor relay base Screw termi up to 14 AWG 2.0 mm Relay type Form C Rating 2.0 30 VDC resistive 0.3 A 110 VDC inductive 1.0 A VDC inductive Plug in System Sensor isolator detector base 25 devices between isolator bases see DF 52389 Retrofit flange to convert B210LP A to match the profile or to convert older high profile bases to Bulk pack of F110 package contains 15 Replacement flange for B210LP A base Remote LED annunciator 3 32 VDC Mounts to U S single gang electrical box For use with B501 A and bases only Surface mounting kit magnet Test magnet with telescoping handle Detector removal tool Allows installation and or of detector heads from bases in high ceiling applica Extension pole for XR2B Comes in three 5 foot 1.524 sections Detector removal tool without pole 2.1 5.3 cm high base determines diameter B210LP A 6.1 15.5 cm diameter B501 A 4.1 10.4 cm diameter B200SR A 6.875 17.46 cm diameter B224RB A 6.2 15.748 cm diameter weight 4.8 oz 137 g temperature H355 A H355R A to 100 to 38 H355HT A to 150 to 66 range 10 to 93 relative humidity noncon range 15 to 32 VDC peak current 300 24 VDC one communication five seconds with LED blink enabled current 6.5 mA 24 VDC B210LP A flanged base included See Information Intelligent Bases if using a different base setpoint 135 57 for the H355 A H355R A 190 88 for the H355HT A detection responds to greater than 15 8.3 minute and Approvals and approvals below apply to the H355 A Series In some cases certain modules may not be listed certain approval agencies or listing may be in process factory for latest listing status UL Listed S2517 ULC Listed models H355A H355RA H355HTA CSFM approved 7270 0075 0195 FM approved Line Information suffix indicates ULC Listed model Intelligent thermal sensor 135 F 57 C B210LP base Same as H355 but with ULC Listing B210LPA base Same as H355 with rate of rise feature B210LP base Same as H355R but with ULC Listing B210LPA included Intelligent fixed high temperature thermal detector F 88 C B210LP base included Same as H355HT but with ULC Listing B210LPA included Alarms is a registered trademark of Honeywell International Inc by Honeywell International Inc All rights reserved Unauthorized use this document is strictly prohibited document is not intended to be used for installation purposes We try to keep our product information up to date and accurate cannot cover all specific applications or anticipate all requirements specifications are subject to change without notice more information contact Fire Alarms Phone 800 627 3473 FAX 877 699 4105 in the U S A 2 of 2 DF 52385 D 5 17 2013

Related Files