Fire-Lite IPDACT-2 2UD

File Preview
File Preview
Click below to download for free

File Data

Name fire-lite-ipdact-2-2ud-3509416827.pdf
Type PDF
Size 949.05 KB
Downloads

Text Preview

IPDACT 2 2UD IP Series IP Fire Alarm Communicator new FireWatch IPDACT 2 and IPDACT 2UD are com based on the original IPDACT optional digital communications module Fire The new duplicates the previous function found in the origi IPDACT but adds two supervised inputs two additional an improved terminal strip and the addition of several panels to the compatibility list The IPDACT 2UD ver 6.0 adds a modem daughter board 2UD that supports over the Internet or a customer Intranet to the IPDACT Series Installation Document PN 53109 more information models connect to the primary and secondary communi ports of the panel DACT converting the analog signals digital signals at the panel for transmission to a compatible VisorALARM PLUS IP receiver at a central station The operates normally during an alarm supervisory or trou event and sends contact ID formatted analog information of the telephone ports to the IP Communicator The IP reformats the data into highly encrypted Ether UDP packets for transmission to a compatible receiver at central station This new listing only requires an IP connec No backup analog phone line is necessary Customers still use a traditional backup phone line from the panel phone port if desired Contact ID DACT equipped panels from Fire the IP allow for faster and more economic digital transmissions improving response times and decreas costs found with traditional analog systems They offer features such as supervised line functionality a central station can detect any off line alarm panels seconds On the central station side a compatible Plus IP receiver from the Teldat Corporation popular receiver formats and allows seamless inte into existing conventional central station architectures benefit of an IP Communicator is that it is always on the security and supervision of the central station from once every 24 hours for a supervisory test to once every 30 90 seconds IPDACT 2UD allows a programmer to upload and down data between the user PC and a supported fire alarm The panel and PC can be anywhere on the world wide or within a corporate intranet user computer runs a program called UDPORT exe to the modem signals from Fire PK PLUS or the the user enters the main IP address of the receiver the UDP port to use username and Instead of using the PC modem this process between the IPDACT 2UD modem at the and the panel own modem While speed is still limited the baud rate of the panel modem panel communications now 100 digital over IP from the remote program PC all way to the remote panel installation This eliminates any in modem communications caused by noise or other If an alarm should occur during upload or download panel is able to interrupt modem communications immedi and transmit the alarm to the central station PS Tools panel programming software A3 35 IPDACT 2UD is registered in the VisorALARM Receiver a unique serial number A subscriber number must be into the subscriber number database field for each This same number is entered into the sub telephone number field panel to call in PK PLUS or as if calling the panel on a telephone If these num match and the master username and password are cor full duplex communication is permitted to the panel UL 864 Ninth Edition prohibits downloading to a panel with entering a local panel password Uploading is permitted at any without entering a password Listed to UL Standard 864 Ninth Edition when used with UL 864 Ninth Edition listed panels Eliminates the cost of two dedicated phone lines Only the shared IP equipment is required connection supervision to the central station from once a day test signal to once every 30 90 seconds Requires no change to the existing panel configuration The Communicator connect directly to the primary and sec analog panel telephone ports Fast alarm transmission less than 10 second transmission Works over any type of customer provided Ethernet 10 100 network connection LAN or WAN DSL modem or modem Data transmits over standard contact ID protocol but is with the industry highest level of encryption AES bit Supports both dynamic DHCP or Public and Private Static addressing Supports dual destination IP receiver address for high configurations all signals are sent to a second address should the primary become unavailable User programmable UDP ports for flexibility and compatibil with firewalls and other network security components Supports an optional third maintenance receiver installed at end user facility that permits local alarm monitoring 10 15 2014 Page 1 of 4 are received simultaneously at both the central sta and the customer facility A filter can be applied to specific alarm types such as trouble only Supports upload download using existing familiar program tools Two supervised inputs and two outputs to Program are three ways to configure the IP Communicator Console terminal using the HyperTerminal software found on all Microsoft operating systems Local or remote Telnet session via Ethernet connection Windows based configuration software shipped with IP IP Communicator can be pre programmed The program enters all central station information and an auto registra password This is saved to the unit flash memory When IP Communicator is installed at the site and connected to Internet Intranet it registers itself with the central station This eliminates the need for a PC at the remote site programming The IP receiver at the monitoring station will configure other parameters during registration For most installations the only required parameters are Selection of either DHCP or Static IP Destination primary and secondary receiver IP addresses Account identification number CID Port number of these parameters are assigned by the central station Requirements for full details password Capabilities IPDACT 2 2UD unit is compatible with the following fire panels MS 5024UD MS 5210UD MS 9200UD MS MS 9600 optional DACT UD MS or MS 9600LS with optional DACT UD2 MS MS 10UD and MS 9050UD Use 411 or 411UD Slave and HP300ULX power supply to connect to Alarm Trou and Supervisory relay outputs of any competitive fire following panels require an external enclosure kit PN or optional HP300ULX power supply with bracket kit IPBRKT both enclosures must be close nipple to the MS 5024UD MS 5210UD MS 9200UD MS 9600 with optional DACT UD 411 or 411UD Slave Dialer for use with any competitive panel using 411 or 411UD Slave Dialer with a competitive fire the HP300ULX power supply is required for mounting powering the IP Communicator Order bracket kit PN separately Both enclosures must be close nippled to FACP following panels may use an internal mounting bracket IPBRKT for use with the common enclosure or can use HP300ULX power supply when more power is required MS 9050UD MS 9200UDLS MS 9600UDLS or MS 9600LS with optional DACT UD2 2 of 4 DF 60407 D3 10 15 2014 MS 5UD MS 10UD See Requirements for current draws Communicator PLUS IP Receiver FireWatch IP receiver manufactured by the Teldat Each IP receiver can manage up to 3,000 IP accounts and is compatible with existing cen station alarm monitoring software VisorALARM IP receiver is based on high availability technology and uses a high performance embedded system for higher reliability and efficiency All IP configuration and operati

Related Files