Fire-Lite IPDACT-2(UD) Dm 387-Iv3 Quick Start Programming Guide

File Preview
File Preview
Click below to download for free

Text Preview

Communicator Dm 387 Iv3 Start Programming Guide using a PC Serial Port TS563 2 Requirements Panel Id compatible panel with tone dialing Existing PSTN Service for backup communication lines PC with RS 232 serial port Console cable for the IPDACT 2 UD Range Maximum 12VDC Maximum 24VDC VDC 180 mA NSC 230 mA Alarm 185 mA NSC 230 mA Alarm 93 mA NSC 136 mA Alarm 98 mA NSC 155 mA Alarm Access a static IP address always the same or a dynamic IP address could be different every time connection is made are possible Checklist console access password default is 24680 password required to execute the register command address subnet mask and gateway for IPDACT 2 UD 2 account number or client number address and UDP Port number of the VisorALARM central station Please obtain the following information from your central monitoring station If you have a DHCP server in the network to which the IPDACT 2 UD connects these parameters can be obtained automatically Physical Connections to the PRIMARY and SECONDARY FIRE PANEL PHONE LINE connections to the TO AP terminal are interchangeable voltage 72 VDC current 22 mA 600 be connected to supplied 1K resistors factory installed the power supply from the Fire Alarm Panel or other electric a broadband modem router or a network switch hub for internet with a IEEE 802.3 interface AP INPUT2 12 24V Network IPDACT 2 UD Default Configuration a short circuit in the IPDACT 2 UD P1 jumper during the start up process you can the IPDACT 2 UD with the default factory settings The process for this is as off the IPDACT 2 UD circuit the jumper with the supplied berg header on the device maintain the jumper short circuited during the first A D LEDs burst the LEDs on and off and undo the short circuit during the second burst the process has executed successfully the IPDACT 2 UD will display a third burst the default configuration has been activated Serial Port Programming order to use the serial port you need to connect the cable designed to this end which must obtained either from Fire Lite or from an authorized distributor The following figures show cable and the connection mode to the IPDACT 2 UD the serial cable to the IPDACT 2 UD as shown above the other end to a PC serial and use a terminal emulation program Windows HyperTerminal for example the serial port to 9600 bps 8 data bits 1 stop bit without parity and no flow When you connect the terminal emulation program you will be asked for a The factory default value is Enter this and the following menu will Accepted Main Menu Configuration a Generic MIP config b Transmission Parameters c Quick Install Monitoring d General Info e Remote Monitor f Events g IP Connectivity z Exit option c Quick Install a DHCP client ON b IP addr 192.168.0.100 mask 255.255.255.0 c Gateway IP 192.168.0.200 d Account Number 0 e Supervisory Main f Supervisory Backup g Maintenance h Port 80 i Register MIP j Reset k AutoRegister MIP z Exit deals with an options menu where option is represented by a letter the title Each option accesses a or contains a parameter value select an option enter this and press ENTER device installation access the Quick menu by pressing c and then figure will be presented All the to install the device are found this menu The steps to complete the are as follows The menu displayed in the LAN network where the IPDACT 2 UD is installed you have address through DHCP go to step 3 If this is not the case carry out the steps Press the key followed by ENTER You will be asked for the IP Enter the IP address you have been given and press ENTER You are now asked for the mask Enter the IP mask you have been and press ENTER OK should now appear on the PC display which will then show the list of that appear in option b the parameters that have just been the key followed by the ENTER You will be asked for the gateway IP Insert the value indicated for the parameter and then press ENTER should now appear on the PC display which will then show the list of that appear in option c the value that has just been entered d followed by the ENTER key You will be asked for the client subscriber Enter the value indicated for the parameter and then press ENTER OK now appear on the PC display which will then show the list of parameters appear in option d the value that has just been entered e followed by the ENTER key You will be asked for the VisorALARM IP address Enter the value indicated for the parameter and then press OK should now appear on the PC display which will then show the list of that appear in option e the value that has just been entered h followed by the ENTER key You will be asked for the VisorALARM UDP port Enter the value indicated for the parameter and then press OK should now appear on the PC display which will then show the list of that appear in option h the value that has just been entered j followed by the ENTER key to reboot the device so these changes activate will be asked for a password Enter 24680 which is the default factory value After a few second the IPDACT 2 UD will reboot rebooting you will be asked for a password Enter 24680 again and the initial will appear in the PC display c and ENTER to access the Quick Install menu once more i and ENTER so the IPDACT 2 UD register procedure in the VisorALARM is carried out You will be asked for a password Enter the installer you have been given and press ENTER The OK message should after a maximum of a few seconds and the IPDACT 2 UD must then the relays and light up the LED located next to these This indicates that the is active and has correct connectivity with the VisorALARM any problem occur an ERROR message will appear instead of the OK will be followed by a number which indicates the following Error on answer Received data incorrect Try again If the error contact the technical service VA unreachable There is a problem in the local network The cable may be disconnected or the IP address for the or gateway is incorrectly configured No answer There is a problem in the connection with the This possibly is a problem in the client connection Internet Internet or the network on the central side

Related Files