Fire-Lite LPSD-12 Smoke Detector

File Preview
File Preview
Click below to download for free

File Data

Name fire-lite-lpsd-12-smoke-detector-3691457028.pdf
Type PDF
Size 593.66 KB
Downloads

Text Preview

LPSD 12 Volt Photoelectric Smoke Detector LPSD 12 FEATURES Low Profile Design 2 or 4 Wire Base Compatible Highly Stable Operation Superior RF Transient Protection Low Standby Current 55 uA Nominal Non directional Smoke Chamber Tamper Proof Security Locking Feature Magnetic Detector Operation Check Fire Lite LPSD 12 can be used in all areas where Smoke Detectors are required The LPSD is designed for smoldering and flaming fires which are caused by such fuel sources as wood paper and The BLP series base is designed for this detector is available in either a two or four wire version unit is comprised of an LED source and silicon photo receiving element In a normal standby condition receiving element receives no light from the pulsing source In the event of a fire smoke enters the and light is reflected from the smoke particles to receivingelement The light received is converted into electronic signal Signals are processed in the com circuitry and when two consecutive signals ex the basic level are received within a specified of time the time delay circuit triggers the SCR to activate the alarm signal An LED is contained the detector base and continuously illuminates to indi an alarm condition CONTROL PANELS MS 4412B MS 5012 Clintonville Road CT 06472 203 484 7161 484 7118 1 of 2 7 1994 SPECIFICATIONS Source Voltage Form Current Current Allowable Current Alarm Trip Current Temperature UL Rated Feature As infrared Emitting Diode Voltage 9.4 15.4 VDC Voltage 8.0 17.0 VDC DC average at 12 VDC maximum 77 100 1.3 with Base 1.75 4 with Base 6 Ounces magnetic equivalent to 4 ft 6 ft obscuration SPECIFICATIONS contractor shall furnish and install where indicated on the plans photoelectric smoke detectors Firelite Model The combination head and twist lock base shall be UL listed compatible with a UL listed fire alarm panel head dimensions shall be 1.3 in height and 4 in diameter base shall limit the alarm current available to the detectors Base shall be appropriate twist lock base Model BLP 4W The detector may be reset by actuating the control panel reset switch The sensitivity of the detector shal1 capable of being measured vandal resistant security locking feature shall be used in those areas as indicated on the drawings The locking shall be field removable when not required shall be possible to perform an operational test of the detector without the need of generating smoke The test shall simulate the effects of products of combustion in the chamber to ensure testing of detector circuits facilitate installation the detector shall be non polarized Voltage and RF transient suppression techniques shall employed to minimize false alarm potential LINE INFORMATION Smoke detectors 12VDC Requires a BLP Series Base profile two wire base profile two wire base profile four wire base with resistor Allow use with FireLite MP 12 and MS 4012 panels try to keep our product information up to date and accurate We cannot cover specific applications or anticipate all All specifications are subject to change without notice For more information contact

Related Files