Fire-Lite MDF-300 Dual Monitor Module

File Preview
File Preview
Click below to download for free

File Data

Name fire-lite-mdf-300-dual-monitor-module-3094815276.pdf
Type PDF
Size 991.86 KB
Downloads

Text Preview

InstallatIon anD maIntenance InstructIons FireLite Place CT 06472 203.484.7161 Dual monitor module to 32 VDC mA LED on LED flashing Ohms Ohms Ohms Volts to 120 0 to 49 to 93 Non condensing in H 4.275 in W 1.4 in D Mounts to a 4 in square by 21 8 in deep box Electrical Box Operating Voltage Current Draw Operating Current Resistance SLC Wiring Resistance IDC wiring resistance IDC Voltage IDC Current Range InstallIng information is included as a quick reference installation guide Refer to control panel installation manual for detailed system information If the will be installed in an existing operational system inform the opera and local authority that the system will be temporarily out of service Dis power to the control panel before installing the modules directly to 4 inch square electrical boxes Figure 2A The box must a minimum depth of 21 8 inches Surface mounted electrical boxes are available from FireLite 2 moDule mountIng This manual should be left with the owner user of this equipment DescrIptIon Dual Monitor Module is intended for use in addressable two wire sys It provides two independent 2 wire initiating device circuits IDC at separate consecutive addresses It is capable of monitoring normally contact fire alarm and supervisory devices or either normally open or closed security devices requIrements ensure proper operation this module shall be connected to a compatible system control panel list available from FireLite 1 removIng rotary swItch stop All wiring must conform to applicable local codes ordinances and This module is intended for power limited wiring only Install module wiring in accordance with the job drawings and appropri wiring diagrams Set the address on the module per job drawings NOTE Monitor module L using terminals 6 and 7 responds at the ad set on the code switches Monitor module H using terminals 8 and will automatically respond at the next higher address For example if code switches are set to 76 module L will respond at address 76 and H will respond at address 77 Use caution to avoid duplicate ad of modules on the system Secure module to electrical box supplied by installer as shown in 2 3 typical 2 wire initiating circuit configuration nfpa style B NEXT PANEL OR DEVICE INITIATING DEVICE CIRCUITS L H EACH LIMITED TO 240 11 VDC MAX 47k EOL 47k EOL MODULES TO LISTED CONTROL PANELS ONLY LINE CIRCUIT SLC VDC MAX SHIELDED TWISTED IS RECOMMENDED LISTED CONTACT CLOSURE DEVICES MAY USED DO NOT MIX FIRE ALARM INITIATING OR SECURITY DEVICES ON THE INITIATING DEVICE CIRCUIT CONTACT CLOSURE DEVICES PER INSTALLATION INSTRUCTIONS WIRING SHOWN IS AND POWER LIMITED L TERMINALS 6 7 RESPONDS AT ADDRESS ON CODE SWITCHES MONITOR H TERMINALS 8 RESPONDS AT NEXT HIGHER ADDRESS FireLite Alarms Inc

Related Files