Fire-Lite MMF-300(A) Series, MDF-300 Addressable Monitor Modules

File Preview
File Preview
Click below to download for free

Text Preview

MMF 300 A Series Monitor Modules different monitor modules are available for Fire control panels to suit a variety of applications Moni modules are used to supervise a circuit of dry contact input such as conventional heat detectors and pull stations monitor and power a circuit of two wire smoke detectors is a standard sized module typically mounts to a 10.16 cm square box that supervises either a Style D A or Style B Class B circuit of dry contact input is a miniature monitor module a mere 1.3 3.302 H x 2.75 6.985 cm W x 0.65 1.651 cm D that super a Style B Class B circuit of dry contact input devices Its design allows the MMF 301 A to be mounted in a box behind the device it monitors is a standard sized module used to monitor and compatible two wire 24 volt smoke detectors on a D Class A or Style B Class B circuit is a standard sized dual monitor module used to and supervise two independent two wire Style B B dry contact initiating device circuits IDCs at two consecutive addresses in intelligent two wire sys is a communication protocol developed by Engineering that greatly increases the speed of com between analog intelligent devices Intelligent communicate in a grouped fashion If one of the within the group has new information the panel CPU the group poll and concentrates on single points The effect is response speed greater than five times that of communication protocols Monitor Module Built in type identification automatically identifies this device a monitor module to the control panel Powered directly by two wire SLC loop No additional required High noise EMF RFI immunity SEMS screws with clamping plates for ease of wiring Direct dial entry of address 01 159 on MS 9600 series 01 99 on other compatible systems LED flashes during normal operation and latches on steady indicate alarm MMF 300 A Monitor Module is intended for use in intelli two wire systems where the individual address of each is selected using the built in rotary switches It pro either a two wire or four wire fault tolerant Initiating Circuit IDC for normally open contact fire alarm and devices The module has a panel controlled LED The MMF 300 A can be used to replace M300 A in existing systems APPLICATIONS to monitor a zone of four wire smoke detectors manual alarm pull stations waterflow devices or other normally dry contact alarm activation devices May also be used monitor normally open supervisory devices with special E 325 Devices Type H indication at the control panel Monitored circuit be wired as an NFPA Style B Class B or Style D Class Initiating Device Circuit A 47K Ohm End of Line Resistor terminates the Style B circuit No resistor is required supervision of the Style D circuit OPERATION MMF 300 A uses one of available module on an SLC loop It responds to regular polls from control panel and reports its type and the status open nor of its Initiating Device Circuit IDC A flashing LED that the module is in communication with the control The LED latches steady on alarm subject to current on the loop SPECIFICATIONS operating voltage 15 to 32 VDC current draw 5.0 mA LED on operating current 375 LED flashing 1 com every 5 seconds 47k EOL IDC wiring resistance 1500 Ohms IDC Voltage 11 Volts resistance 47K Ohms range 32 to 120 0 to 49 range 10 to 93 noncondensing 4.5 11.43 cm high x 4 10.16 cm wide x 3.175 cm deep Mounts to a 4 10.16 cm square x 5.398 cm deep box Mini Monitor Module Built in type identification automatically identifies this device a monitor module to the panel Powered directly by two wire SLC loop No additional required High noise EMF RFI immunity 07 30 2015 Page 1 of 4 Tinned stripped leads for ease of wiring Direct dial entry of address 01 159 on MS 9600 series 01 99 on other compatible systems MMF 301 A Mini Monitor Module can be installed in a junction directly behind the monitored unit Its size and light weight allow it to be installed without rigid The MMF 301 A is intended for use in intelligent systems where the individual address of each module selected using rotary switches It provides a two wire initiat device circuit for normally open contact fire alarm devices MMF 301 A can be used to replace M301 A modules in systems APPLICATIONS to monitor a single device or a zone of four wire smoke manual fire alarm pull stations waterflow devices other normally open dry contact devices May also be used monitor normally open supervisory devices with special indication at the control panel Monitored circuit is wired as an NFPA Style B Class B Initiating Device A 47K Ohm End of Line Resistor provided terminates circuit OPERATION available module MMF 301 A uses one of on an SLC loop It responds to regular polls from control panel and reports its type and the status open nor of its Initiating Device Circuit IDC SPECIFICATIONS operating voltage 15 to 32 VDC operating current 350 1 communication every seconds 47k EOL 600 Max Communicating IDC IDC wiring resistance 1500 Ohms IDC Voltage 11 Volts IDC Current 450 resistance 47K Ohms range 32 to 120 0 to 49 range 10 to 93 noncondensing 1.3 3.302 cm high x 2.75 6.985 cm wide x 1.651 cm deep length 6 15.24 cm minimum Interface Module Supports compatible two wire smoke detectors 2 of 4 DF 52121 E 07 30 2015 Supervises IDC wiring and connection of external power High noise EMF RFI immunity SEMS screws with clamping plates for ease of wiring Direct dial entry entry of address 01 159 on MS 9600 panels 01 99 on other compatible systems LED flashes during normal operation LED latches steady to indicate alarm on command from panel MMF 302 A Interface Module is intended for use in intelli addressable systems where the individual address of module is selected using built in rotary switches This allows intelligent panels to interface and monitor two conventional smoke detectors It transmits the status open or alarm of one full zone of conventional back to the control panel All two wire detectors monitored must be UL compatible with the module The can be used to replace M302 A modules in systems A APPLICATIONS the MMF 302 A to monitor a zone of two wire smoke The monitored circuit may be wired as an NFPA B Class B or Style D Class A Initiating Device Circuit 3.9 K Ohm End of Line Resistor provided terminates the of the Style B or D class B or A circuit maximum IDC resistance is 25 Ohms Install ELR across terminals 8 9 for Style D application OPERATION MMF 302 A uses one of available module on an SLC loop It responds to regular polls from control panel and reports its type and the status open nor of its Initiating Device Circuit IDC A flashing LED that the module is in communication with the control The LED latches steady on alarm subject to current on the loop SPECIFICATIONS operating voltage 15 to 32 VDC current draw 5.1 mA LED on IDC wiring resistance 25 Ohms operating current 270 1 communication and 1 flash every 5 seconds 3.9k eol resistance 3.9K Ohms supply voltage between Terminals T10 and T11 DC voltage 24 volts power limited Ripple voltage 0.1 Vrms maximum Current 90 mA per module maximum range 32 to 120 0 to 49 rang

Related Files