Fire-Lite MMF-300 Monitor Module Installation Instructions

File Preview
File Preview
Click below to download for free

Text Preview

Specifications Operating Voltage Resistance IDC Resistance Range Monitor Module Instructions to 32 VDC Ohms Ohms to 120 0 to 49 to 93 Noncondensing H x 4 W x 11 4 D Mounts to a 4 square by 21 8 deep box Electrical Box Installing information is included as a quick reference installation guide Refer to the control panel installation manual for detailed system If the modules will be installed in an existing operational system inform the operator and local authority that the system be temporarily out of service Disconnect power to the control panel before installing the modules This manual should be left with the owner user of this equipment Description MMF 300 Monitor Module is intended for use in addressable two wire systems where the individual address of each module is se using the built in rotary switches It provides either a 2 wire or 4 wire fault tolerant Initiating Device Circuit IDC for normally open fire alarm or supervisory devices The module has a panel controlled LED indicator The MMF 300 can be used to replace an module in existing systems Requirements ensure proper operation these modules shall be connected to listed compatible system control panels only MMF 300 mounts directly to 4 square electrical boxes see Figure 2 The box must have a minimum depth of 21 8 Surface electrical boxes SMB500 are available All wiring must conform to applicable local codes ordinances and regulations This module is intended for power limited wiring only Install module wiring in accordance with the job drawings and appropriate wiring diagrams Set the address on the module per job drawings Some panels support extended addressing In order to set the module above address 99 on Fire compatible systems remove the stop on the upper rotary switch with thumb in the direction shown in Figure 1 Secure module to electrical box supplied by installer as shown in Figure 2 1 Controls and indicators 2 mounting 865 6 7 8 9 10 2 1 8 9 Alarms Inc One Fire Lite Place Northford CT 06472 203 484 7161 3 Typical 2 wire Initiating Device Circuit IDC configuration NFPA Style B Class B NEXT NUMBER OF UL LISTED CONTACT CLOSURE MAY BE USED DO NOT MIX FIRE INITIATING SUPERVISORY OR DEVICES ON THE SAME MODULE K EOL DEVICE CIRCUIT IDC NFPA STYLE B LIMITED 230 MAX 12 VDC MAX CONTACT CLOSURE DEVICES PER INSTALLATION INSTRUCTIONS NEXT NUMBER OF UL LISTED CONTACT CLOSURE MAY BE USED DO NOT MIX FIRE INITIATING SUPERVISORY OR DEVICES ON THE SAME MODULE 865 6 7 8 9 865 6 7 8 9 PANEL OR DEVICE MODULES TO LISTED COMPATIBLE CONTROL PANELS ONLY LINE VDC MAX PAIR RECOMMENDED WIRING SHOWN IS SUPERVISED AND POWER LIMITED PANEL OR DEVICE MODULES TO LISTED COMPATIBLE CONTROL PANELS ONLY RESISTOR INTERNAL AT 8 9 LINE VDC MAX PAIR RECOMMENDED CONTACT CLOSURE DEVICES PER INSTALLATION INSTRUCTIONS WIRING SHOWN IS SUPERVISED AND POWER LIMITED 4 Typical 4 wire fault tolerant Initiating Device Circuit IDC configuration NFPA Style D Class A Fire Alarms Inc

Related Files