Fire-Lite MRP-2001(C) Deluge - Preaction Control Panel
File Preview
Click below to download for free
Click below to download for free
File Data
Name | fire-lite-mrp-2001-c-deluge-preaction-control-panel-8921074635.pdf |
---|---|
Type | |
Size | 830.71 KB |
Downloads |
Text Preview
MRP 2001C Preaction Control Panel MRP 2001C is a six zone FACP for single and dual haz deluge and preaction applications The MRP 2001C pro reliable fire detection signaling and protection for industrial and institutional buildings requiring releasing The MRP 2001C is compatible with Sensor i3 detectors which are conventional smoke that can transmit a maintenance trouble signal to the indicating the need for cleaning and a supervisory signal when the ambient temperature falls below the rating of approximately 7.22 In addition the control is compatible with conventional input devices such as smoke detectors four wire smoke detectors pull sta waterflow devices tamper switches and other normally contact devices Refer to the Fire Device Compati Document for a complete listing of compatible devices outputs are programmable as NACs Notification Appli Circuits or releasing circuits Three programmable relays factory programmed for Alarm Trouble and and 24 VDC special application resettable and power outputs are also included on the main board The MRP 2001C supervises all wiring AC volt battery charger and battery level of a compatible smoke detector or any normally fire alarm initiating device will activate audible and visual devices illuminate an indicator display alarm infor on the panel LCD sound the piezo sounder at the activate the FACP alarm relay and operate an optional used to notify a remote station or initiate an auxiliary function Listed to Standard ULC S527 11 FM Approved Designed for sprinkler standards NFPA 13 15 and 16 Dual hazard operation Adjustable waterflow discharge timer and two soak timers Cross zone double interlock capability Six programmable Style B Class B IDCs Initiating Device System Sensor i3 series detectors compatible Four programmable Style Y Class B output circuits spe application power Strobe Synchronization System Sensor Wheelock Gentex Faraday Amseco Three programmable Form C relays 7.0 amps total 24 VDC output current Resettable and non resettable output power Built in Programmer DF 60441 B2 Control Panels ANN BUS for connection to optional devices one or 2 of of the following ANN 80C Remote LCD Indicator ANN I O LED Driver ANN S PG Printer Module ANN RLY Relay Module ANN LED Annunciator Module built in 80 character LCD display backlit Real time clock calendar with daylight savings time control History log with 256 event storage Piezo sounder for alarm trouble and supervisory 24 volt DC operation Low AC voltage sense Outputs Programmable for Releasing circuits or NACS NACs programmable for Silence Inhibit Strobe Synchronization Selective Silence horn strobe mute Temporal or Steady Signal Silenceable or Non silenceable Release Stage Sounder Disable Enable control per input zone and output zone Extensive transient protection Automatic battery charger with charger supervision Supplied Dress Panel DP 51050 red Optional Trim Ring TR CE red for semi flush mounting the 8 31 2016 Page 1 of 4 Optional CAC 5X Class A Converter Module for Outputs IDCs Optional 4XTMF Municipal Box Transmitter Module Optional Digital Alarm Communicators 411UD 411UDAC Optional ANN SEC card for a secondary ANN BUS AND SOFTWARE Custom English labels per point may be manually entered selected from an internal library file Three programmable Form C relay outputs Pre programmed and custom application templates Continuous fire protection during online programming at the panel Program Check automatically catches common errors not to any zone or input point INTERFACE Real time clock calendar with automatic daylight savings 80 character LCD display with backlighting ANN Bus for connection to annunciators or remote indica Audible or silent walk test capabilities Piezo sounder for alarm trouble and supervisory and Indicators INDICATORS FIRE ALARM red SUPERVISORY yellow TROUBLE yellow AC POWER green ALARM SILENCED yellow DISCHARGE red BUTTONS ACKNOWLEDGE SIGNAL SILENCE SYSTEM RESET lamp test ALARM SIGNAL Power TB1 MRP 2001C 120 VAC 60 Hz 3.66 amps Wire size Minimum 14 AWG 2.0 mm2 with 600V insula Supervised nonpower limited sealed lead acid only J12 Maximum Charging Circuit Normal Flat Charge 27.6 1.4 amp Supervised nonpower limited Maximum Charger Capacity 18 Amp Hour battery two Amp Hour batteries can be housed in the FACP cabinet batteries require separate battery box such as the or BB 55 Minimum Battery Size 12 Amp Hour Device Circuits TB4 and TB6 Alarm Zones 1 5 on TB4 Alarm Zone 6 on TB6 Supervised and power limited circuitry Style B Class B wiring with Style D Class A option Normal Operating Voltage Nominal 20 VDC Alarm Current 15 mA minimum 2 of 4 Canadian DF 60441 B2 8 31 2016 Short Circuit Current 40 mA max Maximum Loop Resistance 100 Ohms End of Line Resistor 4.7K Ohms 1 2 watt PN 71252 Standby Current 4 mA to the Fire Device Compatibility Document for listed devices Appliance and Releasing Circuit s TB5 and Four Output Circuits Style Y Class B or Style Z Class A with optional con module Special Application power Supervised and power limited circuitry Normal Operating Voltage Nominal 24 VDC Maximum Signaling Current 7.0 amps 3.0 amps special 300 mA regulated maximum per NAC End of Line Resistor 4.7K Ohms 1 2 watt PN 71252 Max Wiring Voltage Drop 2 VDC to the Fire Compatibility Document for com listed devices Relays Programmable TB8 Relay 1 factory default programmed as Alarm Relay Relay 2 factory default programmed as fail safe Trouble Relay 3 factory default programmed as Supervisory Relay Contact Ratings 2 amps 30 VDC resistive 0.5 amps 30 VAC resistive Trouble Input J6 Auxiliary Trouble Input is an open collector circuit which be used to monitor external devices for trouble conditions can be connected to the trouble bus of a peripheral such as power supply which is compatible with open collector cir Application Resettable Power TB9 Operating Voltage Nominal 24 VDC Maximum Available Current 500 mA appropriate for 4 wire smoke detectors see note 1 Power limited Circuitry to the Fire Device Compatibility Document for com listed devices 1 Total current for resettable power nonresettable power Output Circuits must not exceed 7.0 amps Application Resettable or Nonresettable Power Operating Voltage Nominal 24 VDC Maximum Available Current 500 mA see note 1 Power limited Circuitry Jumper selectable by JP31 for resettable or nonresettable to the Fire Device Compatibility Document for com listed devices Line Information Six zone 24 volt Deluge Preaction Control includes backbox power supply technical manual and frame post operating instruction sheet for single and dual deluge and preaction applications Class A Converter Module can be used to convert Style B Class B Initiating Device Circuits to Style D Class and Style Y Class B Output Circuits to Style Z Class A Two Cla