MS 4412B MS 4424B FIRE ALARM SYSTEM Instructions Only the GREEN A C POWER LED is on other LEDs are off KEY The key to open the panel can be found at location AUDIBLE DEVICES ARE SOUNDING AN ALARM Evacuate the protected area your current status is Notify the monitoring service and or the Fire Department immediately Tell them briefly what happened and Department Service If the Fire Department is responding be prepared to provide directions to arriving firefighters TROUBLE ONLY is happening Notify the monitoring service and or Fire Department if this panel is connected to either one and tell them Silence audible devices by unlocking and opening the panel and pressing the TONE SILENCE switch The SYSTEM TROUBLE LED will remain on Contact authorized service personnel immediately See NOT ALLOW TROUBLE CONDITIONS TO REMAIN LOGGED IN THE SYSTEM THE PROTECTION THE SYSTEM OFFERS HAS BEEN COMPROMISED OR ELIMINATED WHEN A TROUBLE EXISTS return to normal after an alarm Do not enter the protected area until safe to do so Clear all initiating devices Smoke detectors will not reset if is still smoke in the area Reset the control panel PRESS the RESET switch failure or brownout AC power drops too low or fails the POWER ON LED will go the SYSTEM TROUBLE LED will turn on and the panel and any other audible trouble devices will sound authorized service personnel immediately See below Supervisory Silence will silence the piezo and cause the supervisory to illuminate steadily the event of trouble contact the local Service Number Activation Fire Drill or otherwise Appliance Circuits can be activated by pressing ALARM ACTIVATE switch You may want to disconnect the municipal box by the DISCONNECT switch located on the module to its DOWN position Silencing Appliance Circuits may be silenced by pressing ALARM SILENCE switch The ALARM SILENCED LED turn on Subsequent alarms will reactivate circuits the RESET switch to clear the condition The ALARM SILENCE switch may be disabled by switch selection see manual Test the Lamps and hold the RESET switch and check all the LEDs one should be on as long as the RESET switch is on For more information refer to the manual P N It is kept in the following location AND POST THESE INSTRUCTIONS TO THE PANEL 15071 Rev A 10 27 93

Related Files